Product available Ships today (order by 14:00) CO2 GPSR PPWR REACH

SM 19x225 [2xM6] / N50 - magnetic separator

magnetic separator

Catalog no 130241

GTIN/EAN: 5906301812708

5.00
Diameter Ø
19 mm [±1 mm]
Height
225 mm [±1 mm]
Weight
0.01 g
Magnetic Flux
~ 8 500 Gauss [±5%]

How we measure these parameters — certificates and measurements

430.00net / pcs

528.90 zł with VAT (23% VAT) / pcs

price for transport

bulk discounts:

Need more?

Quantity
Net
Gross
price from 1 pcs
430.00 zł
528.90 zł
price from 10 pcs
408.50 zł
502.46 zł
price from 15 pcs
387.00 zł
476.01 zł

Frequently asked questions

Which rod should I choose for fine contamination?
For particles below 0.5 mm — a Ø32 mm rod in grade N52, with surface induction of about 10,000 Gs. A Ø25 rod in grade N42 gives about 6,500 Gs and is chosen for contamination above 1 mm: bolts, washers, pieces of wire.
Which rod pitch should I choose?
The narrow pitch, 40 mm centre to centre, for fine free-flowing fractions — it gives denser coverage of the cross-section. The wide pitch, 50 mm, for granulates and for damp, greasy or sticky materials, where a narrow pitch risks the material bridging above the rods.
Why does efficiency drop after a few weeks of operation?
Almost always because the separator has not been cleaned. The layer of captured particles shields the field, and further particles settle on that layer rather than on the rod surface, where the gradient is far stronger. The magnets themselves do not weaken at that rate.
Want to talk magnets?

Call us now +48 888 99 98 98 alternatively let us know using contact form the contact section.
Specifications and structure of a neodymium magnet can be estimated using our power calculator.

Order by 14:00 and we’ll ship today!

Technical of the product - SM 19x225 [2xM6] / N50 - magnetic separator

Specification / characteristics - SM 19x225 [2xM6] / N50 - magnetic separator

properties
properties values
Cat. no. 130241
GTIN/EAN 5906301812708
Production/Distribution Dhit sp. z o.o.
ul. Zielona 14 05-850 Ożarów Mazowiecki PL
Country of origin Poland / China / Germany
Customs code 85059029
Diameter Ø 19 mm [±1 mm]
Height 225 mm [±1 mm]
Weight 0.01 g
Material Type Stainless steel AISI 304 / A2
Magnetic Flux ~ 8 500 Gauss [±5%]
Size/Mount Quantity 2xM6
Polarity circumferential - 12 poles
Casing Tube Thickness 0.5 mm
Manufacturing Tolerance ±1 mm

Magnetic properties of material N50

Specification / characteristics SM 19x225 [2xM6] / N50 - magnetic separator
properties values units
Remanence Br ? 14-14.6 kGs
Remanence Br ? 1400-1460 mT
Coercivity bHc ? 10.8-12.5 kOe
Coercivity bHc ? 860-995 kA/m
Intrinsic coercivity iHc ≥ 12 kOe
Intrinsic coercivity iHc ≥ 955 kA/m
Energy product BHmax ? 47-51 BH max MGOe
Energy product BHmax ? 374-406 BH max KJ/m
Maximum working temperature ? ≤ 80 °C

Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C

Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C
properties values units
Vickers hardness ≥550 Hv
Density ≥7.4 g/cm3
Curie Temperature TC 310 °C
Curie Temperature TF 590 °F
Specific resistance 150 μΩ⋅cm
Bending strength 250 MPa
Compressive strength 1000~1100 MPa
Thermal expansion parallel (∥) to orientation (M) (3-4) x 10-6 °C-1
Thermal expansion perpendicular (⊥) to orientation (M) -(1-3) x 10-6 °C-1
Young's modulus 1.7 x 104 kg/mm²

Table 1: Rod construction
SM 19x225 [2xM6] / N50

Parameter Value Description / Unit
Diameter (Ø) 19 mm
Total length 225 mm (L)
Active length 189 mm
Section count 8 modules
Dead zone 36 mm (2x 18mm starter)
Weight (est.) ~485 g
Active area 113 cm² (Area)
Housing material AISI 304 1.4301 (Inox)
Surface finish Ra < 0.8 µm Polished
Temp. class 80°C Standard (N)
Force loss (at max °C) -12.8% Reversible loss (physics)
Force (calculated) 10.4 kg (theor.)
Induction (surface) ~8 500 Gauss (Max)

Chart 2: Field profile (8 sections)

Chart 3: Temperature performance

Technical specification and ecology

Material specification

iron (Fe) 64% – 68%
neodymium (Nd) 29% – 32%
boron (B) 1.1% – 1.2%
dysprosium (Dy) 0.5% – 2.0%
coating (Ni-Cu-Ni) < 0.05%

Environmental data

recyclability (EoL) 100%
recycled raw materials ~10% (pre-cons)
carbon footprint low / zredukowany
waste code (EWC) 16 02 16
Safety card (GPSR)
responsible entity
Dhit sp. z o.o.
ul. Kościuszki 6A, 05-850 Ożarów Mazowiecki
tel: +48 22 499 98 98 | e-mail: bok@dhit.pl
batch number/type
id: 130241-2026
Quick Unit Converter

Magnet pull force


Magnetic Induction

See also proposals

A magnetic rod is the basic element of building grate separators and magnetic filters. Its task is separation (separation) of metal filings from the transported material. High magnetic induction on the surface allows catching the finest iron particles.
The outer layer is hygienic acid-resistant steel, approved for food contact. The core is a precise magnetic system generating high induction (Gauss). Thanks to this, the rod is durable, hygienic, and easy to keep clean.
Metal contaminants are strongly attracted, so removing them with a bare hand or glove can be difficult. You can use compressed air or special non-magnetic strippers (rings). In industry, cover tubes (so-called Easy Clean system) are used, from which the magnetic insert slides out.
The more Gauss, the smaller and more weakly magnetic particles will be effectively caught. Standard rods (~8000 Gs) are sufficient for catching screws, nails, and steel shavings. For the food and precision industry, we recommend the highest induction parameters.
Yes, as a manufacturer, we make rods of any length and diameter (standard is dia 25mm and 32mm). The rod end is strictly adapted to the fastening system in your device. We ensure fast realization of special orders and technical advice.

Advantages and disadvantages of rare earth magnets.

Strengths

Apart from their superior holding force, neodymium magnets have these key benefits:
  • They do not lose power, even after approximately 10 years – the decrease in strength is only ~1% (theoretically),
  • They retain their magnetic properties even under strong external field,
  • In other words, due to the glossy finish of nickel, the element gains visual value,
  • Magnets possess excellent magnetic induction on the active area,
  • Thanks to resistance to high temperature, they are able to function (depending on the shape) even at temperatures up to 230°C and higher...
  • Thanks to the possibility of precise shaping and adaptation to specialized projects, magnetic components can be modeled in a variety of forms and dimensions, which expands the range of possible applications,
  • Key role in advanced technology sectors – they serve a role in mass storage devices, drive modules, precision medical tools, and other advanced devices.
  • Compactness – despite small sizes they generate large force, making them ideal for precision applications

Cons

Disadvantages of NdFeB magnets:
  • To avoid cracks under impact, we recommend using special steel housings. Such a solution secures the magnet and simultaneously improves its durability.
  • Neodymium magnets decrease their power under the influence of heating. As soon as 80°C is exceeded, many of them start losing their power. Therefore, we recommend our special magnets marked [AH], which maintain durability even at temperatures up to 230°C
  • When exposed to humidity, magnets usually rust. For applications outside, it is recommended to use protective magnets, such as magnets in rubber or plastics, which prevent oxidation and corrosion.
  • We suggest a housing - magnetic mount, due to difficulties in creating nuts inside the magnet and complicated forms.
  • Potential hazard to health – tiny shards of magnets can be dangerous, when accidentally swallowed, which becomes key in the context of child health protection. Additionally, tiny parts of these magnets can complicate diagnosis medical in case of swallowing.
  • Higher cost of purchase is one of the disadvantages compared to ceramic magnets, especially in budget applications

Holding force characteristics

Detachment force of the magnet in optimal conditionswhat affects it?

Breakaway force is the result of a measurement for the most favorable conditions, assuming:
  • with the contact of a sheet made of low-carbon steel, ensuring maximum field concentration
  • possessing a thickness of min. 10 mm to ensure full flux closure
  • with an ground contact surface
  • with direct contact (no paint)
  • during detachment in a direction vertical to the plane
  • at conditions approx. 20°C

Lifting capacity in practice – influencing factors

Bear in mind that the working load may be lower influenced by the following factors, in order of importance:
  • Clearance – the presence of foreign body (rust, dirt, air) interrupts the magnetic circuit, which reduces capacity steeply (even by 50% at 0.5 mm).
  • Load vector – maximum parameter is reached only during pulling at a 90° angle. The shear force of the magnet along the surface is typically many times lower (approx. 1/5 of the lifting capacity).
  • Substrate thickness – for full efficiency, the steel must be sufficiently thick. Paper-thin metal limits the attraction force (the magnet "punches through" it).
  • Material composition – not every steel reacts the same. Alloy additives weaken the interaction with the magnet.
  • Surface finish – full contact is possible only on polished steel. Any scratches and bumps create air cushions, weakening the magnet.
  • Thermal environment – heating the magnet results in weakening of induction. It is worth remembering the thermal limit for a given model.

Holding force was tested on a smooth steel plate of 20 mm thickness, when a perpendicular force was applied, whereas under shearing force the load capacity is reduced by as much as 75%. In addition, even a slight gap between the magnet and the plate lowers the load capacity.

Safe handling of NdFeB magnets
Powerful field

Be careful. Neodymium magnets act from a distance and snap with massive power, often faster than you can move away.

Danger to pacemakers

Health Alert: Strong magnets can deactivate heart devices and defibrillators. Do not approach if you have medical devices.

Power loss in heat

Keep cool. Neodymium magnets are susceptible to heat. If you need operation above 80°C, inquire about special high-temperature series (H, SH, UH).

Nickel coating and allergies

It is widely known that nickel (standard magnet coating) is a common allergen. For allergy sufferers, prevent direct skin contact and select versions in plastic housing.

Threat to electronics

Device Safety: Neodymium magnets can damage payment cards and sensitive devices (pacemakers, medical aids, mechanical watches).

Risk of cracking

Neodymium magnets are ceramic materials, which means they are very brittle. Impact of two magnets will cause them cracking into shards.

Fire warning

Drilling and cutting of NdFeB material carries a risk of fire hazard. Magnetic powder oxidizes rapidly with oxygen and is hard to extinguish.

Crushing force

Big blocks can break fingers instantly. Never place your hand betwixt two strong magnets.

Threat to navigation

A powerful magnetic field interferes with the operation of magnetometers in phones and GPS navigation. Maintain magnets close to a device to avoid breaking the sensors.

Do not give to children

Neodymium magnets are not toys. Eating multiple magnets can lead to them attracting across intestines, which poses a severe health hazard and requires immediate surgery.

Safety First! Need more info? Check our post: Are neodymium magnets dangerous?