SM 32x225 [2xM8] / N52 - magnetic separator
magnetic separator
Catalog no 130361
GTIN/EAN: 5906301813095
- Diameter Ø
- 32 mm [±1 mm]
- Height
- 225 mm [±1 mm]
- Weight
- 1205 g
- Magnetic Flux
- ~ 10 000 Gauss [±5%]
How we measure these parameters — certificates and measurements
650.00 zł net / pcs
799.50 zł with VAT (23% VAT) / pcs
bulk discounts:
Need more?Frequently asked questions
Which rod should I choose for fine contamination?
Which rod pitch should I choose?
Why does efficiency drop after a few weeks of operation?
Call us now
+48 888 99 98 98
alternatively let us know using
contact form
the contact section.
Specifications and structure of a neodymium magnet can be estimated using our
power calculator.
Order by 14:00 and we’ll ship today!
Technical details - SM 32x225 [2xM8] / N52 - magnetic separator
Specification / characteristics - SM 32x225 [2xM8] / N52 - magnetic separator
| properties | values |
|---|---|
| Cat. no. | 130361 |
| GTIN/EAN | 5906301813095 |
| Production/Distribution | Dhit sp. z o.o. |
| Country of origin | Poland / China / Germany |
| Customs code | 85059029 |
| Diameter Ø | 32 mm [±1 mm] |
| Height | 225 mm [±1 mm] |
| Weight | 1205 g |
| Material Type | Stainless steel AISI 304 / A2 |
| Magnetic Flux | ~ 10 000 Gauss [±5%] |
| Size/Mount Quantity | 2xM8 |
| Polarity | circumferential - 8 poles |
| Casing Tube Thickness | 1 mm |
| Manufacturing Tolerance | ±1 mm |
Magnetic properties of material N52
| properties | values | units |
|---|---|---|
| Remanence Br ? | 14.2-14.7 | kGs |
| Remanence Br ? | 1420-1470 | mT |
| Coercivity bHc ? | 10.8-12.5 | kOe |
| Coercivity bHc ? | 860-995 | kA/m |
| Intrinsic coercivity iHc | ≥ 12 | kOe |
| Intrinsic coercivity iHc | ≥ 955 | kA/m |
| Energy product BHmax ? | 48-53 | BH max MGOe |
| Energy product BHmax ? | 380-422 | BH max KJ/m |
| Maximum working temperature ? | ≤ 80 | °C |
Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C
| properties | values | units |
|---|---|---|
| Vickers hardness | ≥550 | Hv |
| Density | ≥7.4 | g/cm3 |
| Curie Temperature TC | 310 | °C |
| Curie Temperature TF | 590 | °F |
| Specific resistance | 150 | μΩ⋅cm |
| Bending strength | 250 | MPa |
| Compressive strength | 1000~1100 | MPa |
| Thermal expansion parallel (∥) to orientation (M) | (3-4) x 10-6 | °C-1 |
| Thermal expansion perpendicular (⊥) to orientation (M) | -(1-3) x 10-6 | °C-1 |
| Young's modulus | 1.7 x 104 | kg/mm² |
Table 1: Rod construction
SM 32x225 [2xM8] / N52
| Parameter | Value | Description / Unit |
|---|---|---|
| Diameter (Ø) | 32 | mm |
| Total length | 225 | mm (L) |
| Active length | 189 | mm |
| Section count | 8 | modules |
| Dead zone | 36 | mm (2x 18mm starter) |
| Weight (est.) | ~1375 | g |
| Active area | 190 | cm² (Area) |
| Housing material | AISI 304 | 1.4301 (Inox) |
| Surface finish | Ra < 0.8 µm | Polished |
| Temp. class | 80°C | Standard (N) |
| Force loss (at max °C) | -12.8% | Reversible loss (physics) |
| Force (calculated) | 41 | kg (theor.) |
| Induction (surface) | ~10 000 | Gauss (Max) |
Chart 2: Field profile (8 sections)
Chart 3: Temperature performance
Elemental analysis
| iron (Fe) | 64% – 68% |
| neodymium (Nd) | 29% – 32% |
| boron (B) | 1.1% – 1.2% |
| dysprosium (Dy) | 0.5% – 2.0% |
| coating (Ni-Cu-Ni) | < 0.05% |
Ecology and recycling (GPSR)
| recyclability (EoL) | 100% |
| recycled raw materials | ~10% (pre-cons) |
| carbon footprint | low / zredukowany |
| waste code (EWC) | 16 02 16 |
View more deals
Pros as well as cons of rare earth magnets.
Pros
- Their power remains stable, and after approximately 10 years it decreases only by ~1% (according to research),
- They show high resistance to demagnetization induced by external disturbances,
- Thanks to the reflective finish, the surface of nickel, gold-plated, or silver-plated gives an clean appearance,
- Magnetic induction on the working layer of the magnet is impressive,
- Due to their durability and thermal resistance, neodymium magnets are capable of operate (depending on the form) even at high temperatures reaching 230°C or more...
- Thanks to flexibility in constructing and the ability to modify to unusual requirements,
- Huge importance in modern industrial fields – they serve a role in hard drives, electromotive mechanisms, precision medical tools, also industrial machines.
- Compactness – despite small sizes they generate large force, making them ideal for precision applications
Limitations
- To avoid cracks upon strong impacts, we recommend using special steel holders. Such a solution protects the magnet and simultaneously improves its durability.
- When exposed to high temperature, neodymium magnets suffer a drop in power. Often, when the temperature exceeds 80°C, their strength decreases (depending on the size and shape of the magnet). For those who need magnets for extreme conditions, we offer [AH] versions withstanding up to 230°C
- They rust in a humid environment. For use outdoors we advise using waterproof magnets e.g. in rubber, plastic
- Limited possibility of creating threads in the magnet and complex shapes - recommended is a housing - magnet mounting.
- Health risk to health – tiny shards of magnets are risky, if swallowed, which gains importance in the context of child health protection. Furthermore, tiny parts of these magnets are able to complicate diagnosis medical in case of swallowing.
- Higher cost of purchase is a significant factor to consider compared to ceramic magnets, especially in budget applications
Pull force analysis
Breakaway strength of the magnet in ideal conditions – what contributes to it?
- with the use of a sheet made of low-carbon steel, ensuring full magnetic saturation
- possessing a thickness of minimum 10 mm to avoid saturation
- characterized by even structure
- without the slightest clearance between the magnet and steel
- for force acting at a right angle (in the magnet axis)
- at standard ambient temperature
Determinants of practical lifting force of a magnet
- Distance – existence of any layer (paint, tape, air) acts as an insulator, which reduces capacity steeply (even by 50% at 0.5 mm).
- Pull-off angle – remember that the magnet holds strongest perpendicularly. Under shear forces, the capacity drops drastically, often to levels of 20-30% of the nominal value.
- Wall thickness – the thinner the sheet, the weaker the hold. Magnetic flux penetrates through instead of converting into lifting capacity.
- Steel type – low-carbon steel attracts best. Higher carbon content reduce magnetic permeability and holding force.
- Surface condition – ground elements guarantee perfect abutment, which increases force. Rough surfaces weaken the grip.
- Heat – neodymium magnets have a sensitivity to temperature. At higher temperatures they lose power, and in frost gain strength (up to a certain limit).
Lifting capacity was measured by applying a smooth steel plate of suitable thickness (min. 20 mm), under perpendicular pulling force, in contrast under parallel forces the lifting capacity is smaller. In addition, even a slight gap between the magnet and the plate lowers the load capacity.
Safe handling of NdFeB magnets
Bodily injuries
Big blocks can crush fingers instantly. Never place your hand betwixt two strong magnets.
Permanent damage
Monitor thermal conditions. Heating the magnet above 80 degrees Celsius will permanently weaken its properties and strength.
Risk of cracking
Watch out for shards. Magnets can explode upon violent connection, launching shards into the air. Wear goggles.
This is not a toy
Absolutely store magnets out of reach of children. Choking hazard is high, and the effects of magnets clamping inside the body are life-threatening.
Magnetic media
Avoid bringing magnets close to a wallet, computer, or screen. The magnetic field can destroy these devices and erase data from cards.
Phone sensors
A strong magnetic field disrupts the functioning of magnetometers in phones and navigation systems. Keep magnets close to a smartphone to avoid damaging the sensors.
Do not underestimate power
Exercise caution. Neodymium magnets act from a distance and snap with huge force, often faster than you can react.
Fire risk
Dust created during machining of magnets is flammable. Avoid drilling into magnets without proper cooling and knowledge.
Implant safety
People with a ICD must keep an large gap from magnets. The magnetic field can disrupt the operation of the implant.
Allergic reactions
Allergy Notice: The Ni-Cu-Ni coating contains nickel. If an allergic reaction appears, immediately stop handling magnets and use protective gear.