Product available Ships today (order by 14:00) CO2 GPSR PPWR REACH

SM 32x125 [2xM8] / N52 - magnetic separator

magnetic separator

Catalog no 130357

GTIN/EAN: 5906301813057

Diameter Ø
32 mm [±1 mm]
Height
125 mm [±1 mm]
Weight
690 g
Magnetic Flux
~ 10 000 Gauss [±5%]

How we measure these parameters — certificates and measurements

470.00net / pcs

578.10 zł with VAT (23% VAT) / pcs

price for transport

bulk discounts:

Need more?

Quantity
Net
Gross
price from 1 pcs
470.00 zł
578.10 zł
price from 10 pcs
423.00 zł
520.29 zł

Frequently asked questions

Which rod should I choose for fine contamination?
For particles below 0.5 mm — a Ø32 mm rod in grade N52, with surface induction of about 10,000 Gs. A Ø25 rod in grade N42 gives about 6,500 Gs and is chosen for contamination above 1 mm: bolts, washers, pieces of wire.
Which rod pitch should I choose?
The narrow pitch, 40 mm centre to centre, for fine free-flowing fractions — it gives denser coverage of the cross-section. The wide pitch, 50 mm, for granulates and for damp, greasy or sticky materials, where a narrow pitch risks the material bridging above the rods.
Why does efficiency drop after a few weeks of operation?
Almost always because the separator has not been cleaned. The layer of captured particles shields the field, and further particles settle on that layer rather than on the rod surface, where the gradient is far stronger. The magnets themselves do not weaken at that rate.
Want to talk magnets?

Call us now +48 888 99 98 98 alternatively let us know using contact form the contact section.
Specifications and structure of a neodymium magnet can be estimated using our power calculator.

Order by 14:00 and we’ll ship today!

Technical specification - SM 32x125 [2xM8] / N52 - magnetic separator

Specification / characteristics - SM 32x125 [2xM8] / N52 - magnetic separator

properties
properties values
Cat. no. 130357
GTIN/EAN 5906301813057
Production/Distribution Dhit sp. z o.o.
ul. Zielona 14 05-850 Ożarów Mazowiecki PL
Country of origin Poland / China / Germany
Customs code 85059029
Diameter Ø 32 mm [±1 mm]
Height 125 mm [±1 mm]
Weight 690 g
Material Type Stainless steel AISI 304 / A2
Magnetic Flux ~ 10 000 Gauss [±5%]
Size/Mount Quantity 2xM8
Polarity circumferential - 4 poles
Casing Tube Thickness 1 mm
Manufacturing Tolerance ±1 mm

Magnetic properties of material N52

Specification / characteristics SM 32x125 [2xM8] / N52 - magnetic separator
properties values units
Remanence Br ? 14.2-14.7 kGs
Remanence Br ? 1420-1470 mT
Coercivity bHc ? 10.8-12.5 kOe
Coercivity bHc ? 860-995 kA/m
Intrinsic coercivity iHc ≥ 12 kOe
Intrinsic coercivity iHc ≥ 955 kA/m
Energy product BHmax ? 48-53 BH max MGOe
Energy product BHmax ? 380-422 BH max KJ/m
Maximum working temperature ? ≤ 80 °C

Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C

Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C
properties values units
Vickers hardness ≥550 Hv
Density ≥7.4 g/cm3
Curie Temperature TC 310 °C
Curie Temperature TF 590 °F
Specific resistance 150 μΩ⋅cm
Bending strength 250 MPa
Compressive strength 1000~1100 MPa
Thermal expansion parallel (∥) to orientation (M) (3-4) x 10-6 °C-1
Thermal expansion perpendicular (⊥) to orientation (M) -(1-3) x 10-6 °C-1
Young's modulus 1.7 x 104 kg/mm²

Table 1: Rod construction
SM 32x125 [2xM8] / N52

Parameter Value Description / Unit
Diameter (Ø) 32 mm
Total length 125 mm (L)
Active length 89 mm
Section count 3 modules
Dead zone 36 mm (2x 18mm starter)
Weight (est.) ~764 g
Active area 89 cm² (Area)
Housing material AISI 304 1.4301 (Inox)
Surface finish Ra < 0.8 µm Polished
Temp. class 80°C Standard (N)
Force loss (at max °C) -12.8% Reversible loss (physics)
Force (calculated) 41 kg (theor.)
Induction (surface) ~10 000 Gauss (Max)

Chart 2: Field profile (3 sections)

Chart 3: Temperature performance

Engineering data and GPSR

Elemental analysis

iron (Fe) 64% – 68%
neodymium (Nd) 29% – 32%
boron (B) 1.1% – 1.2%
dysprosium (Dy) 0.5% – 2.0%
coating (Ni-Cu-Ni) < 0.05%

Environmental data

recyclability (EoL) 100%
recycled raw materials ~10% (pre-cons)
carbon footprint low / zredukowany
waste code (EWC) 16 02 16
Safety card (GPSR)
responsible entity
Dhit sp. z o.o.
ul. Kościuszki 6A, 05-850 Ożarów Mazowiecki
tel: +48 22 499 98 98 | e-mail: bok@dhit.pl
batch number/type
id: 130357-2026
Quick Unit Converter

Magnet pull force


Magnetic Field

Other offers

This product serves to effectively catch ferromagnetic contaminants from bulk and liquid products. It is commonly used for cleaning flour, sugar, plastic granules, as well as oils and coolants. High magnetic induction on the surface allows catching the finest iron particles.
The rod consists of a cover tube made of high-quality acid-resistant steel (AISI 304 or 316). Inside there is a stack of strong neodymium magnets arranged in a special configuration (magnetic circuit). Such construction ensures full resistance to corrosion, water, oils, and acids.
Due to the high power of the magnet, direct removal of filings can be troublesome and time-consuming. You can use compressed air or special non-magnetic strippers (rings). In industry, cover tubes (so-called Easy Clean system) are used, from which the magnetic insert slides out.
The more Gauss, the smaller and more weakly magnetic particles will be effectively caught. For basic machine protection against pieces of iron, standard power is sufficient. High induction is necessary when contaminants are microscopic or weakly magnetic.
Yes, as a manufacturer, we make rods of any length and diameter (standard is dia 25mm and 32mm). You can choose a mounting method consistent with your technical design. We ensure fast realization of special orders and technical advice.

Pros as well as cons of neodymium magnets.

Advantages

Apart from their superior power, neodymium magnets have these key benefits:
  • They have unchanged lifting capacity, and over nearly ten years their performance decreases symbolically – ~1% (in testing),
  • They are resistant to demagnetization induced by presence of other magnetic fields,
  • In other words, due to the smooth layer of nickel, the element is aesthetically pleasing,
  • Neodymium magnets ensure maximum magnetic induction on a small surface, which ensures high operational effectiveness,
  • Through (adequate) combination of ingredients, they can achieve high thermal resistance, allowing for action at temperatures approaching 230°C and above...
  • Thanks to freedom in shaping and the capacity to modify to unusual requirements,
  • Key role in advanced technology sectors – they are utilized in hard drives, drive modules, medical devices, also other advanced devices.
  • Compactness – despite small sizes they provide effective action, making them ideal for precision applications

Limitations

Disadvantages of NdFeB magnets:
  • Brittleness is one of their disadvantages. Upon strong impact they can break. We recommend keeping them in a steel housing, which not only protects them against impacts but also increases their durability
  • When exposed to high temperature, neodymium magnets experience a drop in strength. Often, when the temperature exceeds 80°C, their strength decreases (depending on the size, as well as shape of the magnet). For those who need magnets for extreme conditions, we offer [AH] versions withstanding up to 230°C
  • When exposed to humidity, magnets usually rust. To use them in conditions outside, it is recommended to use protective magnets, such as magnets in rubber or plastics, which prevent oxidation and corrosion.
  • Due to limitations in creating nuts and complex forms in magnets, we recommend using casing - magnetic mechanism.
  • Potential hazard resulting from small fragments of magnets pose a threat, if swallowed, which gains importance in the context of child safety. Additionally, small components of these products can be problematic in diagnostics medical when they are in the body.
  • Higher cost of purchase is one of the disadvantages compared to ceramic magnets, especially in budget applications

Pull force analysis

Detachment force of the magnet in optimal conditionswhat it depends on?

The declared magnet strength concerns the peak performance, measured under ideal test conditions, namely:
  • on a plate made of mild steel, effectively closing the magnetic flux
  • whose transverse dimension reaches at least 10 mm
  • with a plane cleaned and smooth
  • with direct contact (without coatings)
  • during detachment in a direction vertical to the plane
  • at standard ambient temperature

Magnet lifting force in use – key factors

In real-world applications, the actual lifting capacity depends on many variables, listed from most significant:
  • Clearance – existence of any layer (paint, dirt, air) acts as an insulator, which lowers power steeply (even by 50% at 0.5 mm).
  • Direction of force – maximum parameter is available only during pulling at a 90° angle. The resistance to sliding of the magnet along the plate is standardly several times smaller (approx. 1/5 of the lifting capacity).
  • Wall thickness – thin material does not allow full use of the magnet. Part of the magnetic field passes through the material instead of converting into lifting capacity.
  • Material composition – different alloys attracts identically. Alloy additives worsen the interaction with the magnet.
  • Surface structure – the smoother and more polished the plate, the larger the contact zone and stronger the hold. Unevenness creates an air distance.
  • Thermal factor – high temperature weakens magnetic field. Exceeding the limit temperature can permanently demagnetize the magnet.

Lifting capacity testing was carried out on plates with a smooth surface of suitable thickness, under a perpendicular pulling force, however under shearing force the lifting capacity is smaller. Additionally, even a slight gap between the magnet’s surface and the plate reduces the lifting capacity.

Precautions when working with neodymium magnets
Compass and GPS

Navigation devices and smartphones are highly sensitive to magnetic fields. Close proximity with a powerful NdFeB magnet can decalibrate the internal compass in your phone.

Conscious usage

Use magnets consciously. Their powerful strength can shock even professionals. Stay alert and respect their power.

Product not for children

Adult use only. Tiny parts pose a choking risk, causing intestinal necrosis. Keep away from children and animals.

Do not drill into magnets

Powder generated during machining of magnets is self-igniting. Avoid drilling into magnets without proper cooling and knowledge.

Warning for heart patients

Individuals with a pacemaker have to maintain an large gap from magnets. The magnetism can stop the functioning of the life-saving device.

Electronic devices

Data protection: Strong magnets can damage payment cards and delicate electronics (pacemakers, medical aids, mechanical watches).

Nickel allergy

Warning for allergy sufferers: The nickel-copper-nickel coating contains nickel. If redness occurs, cease working with magnets and use protective gear.

Material brittleness

Neodymium magnets are ceramic materials, which means they are prone to chipping. Clashing of two magnets will cause them cracking into shards.

Pinching danger

Big blocks can smash fingers in a fraction of a second. Under no circumstances put your hand between two attracting surfaces.

Maximum temperature

Control the heat. Heating the magnet to high heat will destroy its magnetic structure and pulling force.

Danger! Need more info? Check our post: Why are neodymium magnets dangerous?