Product available Ships today (order by 14:00) CO2 GPSR PPWR REACH

SM 28x225 [2xM8] / N52 - magnetic separator

magnetic separator

Catalog no 130514

GTIN/EAN: 5906301815051

Diameter Ø
28 mm [±1 mm]
Height
225 mm [±1 mm]
Weight
1078.78 g
Magnetic Flux
~ 8 500 Gauss [±5%]

How we measure these parameters — certificates and measurements

590.00 zł net / pcs

725.70 zł with VAT (23% VAT) / pcs

price for transport

bulk discounts:

Need more?

Quantity
Net
Gross
price from 1 pcs
590.00 zł
725.70 zł
price from 5 pcs
560.50 zł
689.42 zł
price from 10 pcs
531.00 zł
653.13 zł

Frequently asked questions

How do I choose a separator for fine contamination and check availability?
Start with the size and type of contaminant, the material flow and the working surface. Compare the magnetic-field data and dimensions stated on the selected product card, and check current availability there.
Where can I order a separator for a production line, and what should I check?
Match the device to the installation dimensions, material flow, cleaning method and housing requirements. A drawing or the dimensions of the transfer point help determine whether a catalogue model fits or a custom version is needed.
How can I verify a separator's declared magnetic parameters before purchase?
Ask for the measured value, the point of measurement and the method or instrument used. A field-strength figure without its measurement conditions cannot be compared reliably with another product.
Can a magnetic beam withstand continuous work on a production line?
Check the construction, mounting and cleaning procedure for the chosen beam. Captured metal must be removed regularly; a layer of particles can reduce effective separation even when the magnets themselves are sound.
What roller design is suitable for a dusty environment?
Check the bearing protection, surface finish and cleaning access of the selected model. Dust accumulation and abrasion depend on the installation, so specify the actual process conditions before choosing a version.
How do I choose the size of a hand-held separator?
Match the rod diameter and length to the container and material depth, and consider the tool's weight for repeated manual work. Use the dimensions and magnetic data on the current product card.
What is a hand-held separator for, and how is it different from a built-in rod?
A built-in rod stays in the process line. A hand-held separator is moved through a material sample or container and then cleaned. It is useful for spot checks or occasional cleanup when permanent installation is not required.
Which separator type suits a small production plant?
Choose by the point in the process: a grate at a hopper, a beam over a conveyor, a built-in rod in a chute or pipe, or a hand-held tool for spot checks. A magnetic gripper handles steel parts rather than separating contamination.
Want to talk magnets?

Call us now +48 888 99 98 98 alternatively let us know using contact form the contact section.
Specifications and structure of a neodymium magnet can be estimated using our power calculator.

Order by 14:00 and we’ll ship today!

Physical properties - SM 28x225 [2xM8] / N52 - magnetic separator

Specification / characteristics - SM 28x225 [2xM8] / N52 - magnetic separator

properties
properties values
Cat. no. 130514
GTIN/EAN 5906301815051
Production/Distribution Dhit sp. z o.o.
ul. Zielona 14 05-850 Ożarów Mazowiecki PL
Country of origin Poland / China / Germany
Customs code 85059029
Diameter Ø 28 mm [±1 mm]
Height 225 mm [±1 mm]
Weight 1078.78 g
Material Type Stainless steel AISI 304 / A2
Magnetic Flux ~ 8 500 Gauss [±5%]
Size/Mount Quantity M8x2
Polarity circumferential - 8 poles
Casing Tube Thickness 1 mm
Manufacturing Tolerance ±1 mm

Magnetic properties of material N52

Specification / characteristics SM 28x225 [2xM8] / N52 - magnetic separator
properties values units
Remanence Br ? 14.2-14.7 kGs
Remanence Br ? 1420-1470 mT
Coercivity bHc ? 10.8-12.5 kOe
Coercivity bHc ? 860-995 kA/m
Intrinsic coercivity iHc ≥ 12 kOe
Intrinsic coercivity iHc ≥ 955 kA/m
Energy product BHmax ? 48-53 BH max MGOe
Energy product BHmax ? 380-422 BH max KJ/m
Maximum working temperature ? ≤ 60 °C

Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C

Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C
properties values units
Vickers hardness ≥550 Hv
Density ≥7.4 g/cm3
Curie Temperature TC 310 °C
Curie Temperature TF 590 °F
Specific resistance 150 μΩ⋅cm
Bending strength 250 MPa
Compressive strength 1000~1100 MPa
Thermal expansion parallel (∥) to orientation (M) (3-4) x 10-6 °C-1
Thermal expansion perpendicular (⊥) to orientation (M) -(1-3) x 10-6 °C-1
Young's modulus 1.7 x 104 kg/mm²

Table 1: Rod construction
SM 28x225 [2xM8] / N52

Parameter Value Description / Unit
Diameter (Ø) 28 mm
Total length 225 mm (L)
Active length 189 mm
Section count 8 modules
Dead zone 36 mm (2x 18mm starter)
Weight (est.) ~1053 g
Active area 166 cm² (Area)
Housing material AISI 304 1.4301 (Inox)
Surface finish Ra < 0.8 µm Polished
Temp. class 60°C N52
Force loss (at max °C) -8.6% Reversible loss (physics)
Force (calculated) 22.7 kg (theor.)
Induction (surface) ~8 500 Gauss (Max)

Chart 2: Field profile (8 sections)

Chart 3: Temperature performance

Engineering data and GPSR

Elemental analysis

iron (Fe) 64% – 68%
neodymium (Nd) 29% – 32%
boron (B) 1.1% – 1.2%
dysprosium (Dy) 0.5% – 2.0%
coating (Ni-Cu-Ni) < 0.05%

Sustainability

recyclability (EoL) 100%
recycled raw materials ~10% (pre-cons)
carbon footprint low / zredukowany
waste code (EWC) 16 02 16
Safety card (GPSR)
responsible entity
Dhit sp. z o.o.
ul. Kościuszki 6A, 05-850 Ożarów Mazowiecki
tel: +48 22 499 98 98 | e-mail: bok@dhit.pl
batch number/type
id: 130514-2026
Quick Unit Converter

Magnet pull force


Field Strength

Other proposals

This product serves to effectively catch ferromagnetic contaminants from bulk and liquid products. It is commonly used for cleaning flour, sugar, plastic granules, as well as oils and coolants. High magnetic induction on the surface allows catching the finest iron particles.
The construction relies on a sealed, welded stainless steel housing, polished smooth. The core is a precise magnetic system generating high induction (Gauss). Thanks to this, the rod is durable, hygienic, and easy to keep clean.
Metal filings stick to the surface very strongly, so cleaning requires strength or cleverness. The most effective home method is using adhesive tape, which we wrap around the dirt and peel off. For easier operation, it is worth considering ordering a rod in a version with a cleaning sleeve.
The Gauss value tells us how effectively and deeply the magnet will catch contaminants. The economical version (8kGs) handles large pieces of metal perfectly. High Power versions (~12000-14000 Gs) are necessary for catching metallic dust, oxides, and stainless steel after processing.
We fulfill individual orders for bars perfectly matched to your machine or separator. You can choose a mounting method consistent with your technical design. Contact us for a quote on a non-standard dimension.

Strengths and weaknesses of Nd2Fe14B magnets.

Strengths

Apart from their superior magnetic energy, neodymium magnets have these key benefits:
  • They virtually do not lose strength, because even after ten years the performance loss is only ~1% (according to literature),
  • They do not lose their magnetic properties even under close interference source,
  • In other words, due to the glossy finish of silver, the element gains visual value,
  • Neodymium magnets generate maximum magnetic induction on a contact point, which allows for strong attraction,
  • Thanks to resistance to high temperature, they are capable of working (depending on the form) even at temperatures up to 230°C and higher...
  • Thanks to the potential of accurate molding and customization to specialized needs, NdFeB magnets can be manufactured in a wide range of geometric configurations, which expands the range of possible applications,
  • Universal use in future technologies – they are used in magnetic memories, electric motors, precision medical tools, also complex engineering applications.
  • Relatively small size with high pulling force – neodymium magnets offer high power in tiny dimensions, which allows their use in miniature devices

Cons

Cons of neodymium magnets: application proposals
  • To avoid cracks upon strong impacts, we suggest using special steel holders. Such a solution protects the magnet and simultaneously improves its durability.
  • Do not exceed this material temperature limit: 60°C. Overheating may permanently weaken the magnet.
  • When exposed to humidity, magnets start to rust. For applications outside, it is recommended to use protective magnets, such as those in rubber or plastics, which secure oxidation as well as corrosion.
  • We recommend casing - magnetic mechanism, due to difficulties in realizing threads inside the magnet and complex shapes.
  • Potential hazard to health – tiny shards of magnets are risky, in case of ingestion, which is particularly important in the context of child health protection. Furthermore, small components of these magnets can be problematic in diagnostics medical after entering the body.
  • Due to neodymium price, their price is higher than average,

Pull force analysis

Maximum magnetic pulling force – what it depends on?

The lifting capacity listed is a result of laboratory testing conducted under standard conditions:
  • with the application of a sheet made of special test steel, ensuring full magnetic saturation
  • with a cross-section no less than 10 mm
  • with an ideally smooth touching surface
  • under conditions of ideal adhesion (surface-to-surface)
  • for force acting at a right angle (pull-off, not shear)
  • in neutral thermal conditions

Lifting capacity in real conditions – factors

Effective lifting capacity is influenced by specific conditions, including (from priority):
  • Gap (betwixt the magnet and the metal), as even a tiny clearance (e.g. 0.5 mm) leads to a drastic drop in lifting capacity by up to 50% (this also applies to varnish, corrosion or debris).
  • Direction of force – maximum parameter is available only during pulling at a 90° angle. The resistance to sliding of the magnet along the surface is standardly many times lower (approx. 1/5 of the lifting capacity).
  • Wall thickness – thin material does not allow full use of the magnet. Magnetic flux penetrates through instead of generating force.
  • Plate material – low-carbon steel gives the best results. Higher carbon content reduce magnetic properties and holding force.
  • Smoothness – full contact is obtained only on smooth steel. Any scratches and bumps create air cushions, weakening the magnet.
  • Temperature influence – high temperature reduces magnetic field. Too high temperature can permanently damage the magnet.

Lifting capacity was measured by applying a smooth steel plate of optimal thickness (min. 20 mm), under perpendicular detachment force, whereas under parallel forces the holding force is lower. Additionally, even a slight gap between the magnet and the plate lowers the lifting capacity.

Warnings
Operating temperature

Do not overheat. Neodymium magnets are sensitive to heat. If you require operation above 80°C, look for HT versions (H, SH, UH).

Powerful field

Use magnets consciously. Their immense force can surprise even professionals. Stay alert and respect their force.

Data carriers

Do not bring magnets close to a wallet, computer, or screen. The magnetism can destroy these devices and wipe information from cards.

Medical interference

Individuals with a pacemaker have to maintain an large gap from magnets. The magnetism can disrupt the functioning of the life-saving device.

Compass and GPS

A strong magnetic field interferes with the functioning of compasses in smartphones and GPS navigation. Keep magnets near a smartphone to prevent damaging the sensors.

Nickel coating and allergies

Medical facts indicate that the nickel plating (standard magnet coating) is a potent allergen. If you have an allergy, prevent direct skin contact and choose versions in plastic housing.

Fire warning

Dust produced during grinding of magnets is combustible. Avoid drilling into magnets unless you are an expert.

Hand protection

Risk of injury: The attraction force is so immense that it can result in blood blisters, crushing, and even bone fractures. Use thick gloves.

Choking Hazard

These products are not toys. Swallowing a few magnets may result in them pinching intestinal walls, which poses a severe health hazard and requires immediate surgery.

Beware of splinters

Despite the nickel coating, neodymium is brittle and cannot withstand shocks. Avoid impacts, as the magnet may shatter into sharp, dangerous pieces.

Caution! More info about risks in the article: Magnet Safety Guide.