SM 25x400 [2xM8] / N52 - magnetic separator
magnetic separator
Catalog no 130470
GTIN/EAN: 5906301813132
- Diameter Ø
- 25 mm [±1 mm]
- Height
- 400 mm [±1 mm]
- Weight
- 1560 g
- Magnetic Flux
- ~ 8 500 Gauss [±5%]
How we measure these parameters — certificates and measurements
980.00 zł net / pcs
1205.40 zł with VAT (23% VAT) / pcs
bulk discounts:
Need more?Frequently asked questions
Which rod should I choose for fine contamination?
Which rod pitch should I choose?
Why does efficiency drop after a few weeks of operation?
Call us now
+48 888 99 98 98
alternatively let us know using
contact form
the contact section.
Specifications and structure of a neodymium magnet can be estimated using our
power calculator.
Order by 14:00 and we’ll ship today!
Technical details - SM 25x400 [2xM8] / N52 - magnetic separator
Specification / characteristics - SM 25x400 [2xM8] / N52 - magnetic separator
| properties | values |
|---|---|
| Cat. no. | 130470 |
| GTIN/EAN | 5906301813132 |
| Production/Distribution | Dhit sp. z o.o. |
| Country of origin | Poland / China / Germany |
| Customs code | 85059029 |
| Diameter Ø | 25 mm [±1 mm] |
| Height | 400 mm [±1 mm] |
| Weight | 1560 g |
| Material Type | Stainless steel AISI 304 / A2 |
| Magnetic Flux | ~ 8 500 Gauss [±5%] |
| Size/Mount Quantity | M8x2 |
| Polarity | circumferential - 15 poles |
| Casing Tube Thickness | 1 mm |
| Manufacturing Tolerance | ±1 mm |
Magnetic properties of material N52
| properties | values | units |
|---|---|---|
| Remanence Br ? | 14.2-14.7 | kGs |
| Remanence Br ? | 1420-1470 | mT |
| Coercivity bHc ? | 10.8-12.5 | kOe |
| Coercivity bHc ? | 860-995 | kA/m |
| Intrinsic coercivity iHc | ≥ 12 | kOe |
| Intrinsic coercivity iHc | ≥ 955 | kA/m |
| Energy product BHmax ? | 48-53 | BH max MGOe |
| Energy product BHmax ? | 380-422 | BH max KJ/m |
| Maximum working temperature ? | ≤ 80 | °C |
Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C
| properties | values | units |
|---|---|---|
| Vickers hardness | ≥550 | Hv |
| Density | ≥7.4 | g/cm3 |
| Curie Temperature TC | 310 | °C |
| Curie Temperature TF | 590 | °F |
| Specific resistance | 150 | μΩ⋅cm |
| Bending strength | 250 | MPa |
| Compressive strength | 1000~1100 | MPa |
| Thermal expansion parallel (∥) to orientation (M) | (3-4) x 10-6 | °C-1 |
| Thermal expansion perpendicular (⊥) to orientation (M) | -(1-3) x 10-6 | °C-1 |
| Young's modulus | 1.7 x 104 | kg/mm² |
Table 1: Rod construction
SM 25x400 [2xM8] / N52
| Parameter | Value | Description / Unit |
|---|---|---|
| Diameter (Ø) | 25 | mm |
| Total length | 400 | mm (L) |
| Active length | 364 | mm |
| Section count | 15 | modules |
| Dead zone | 36 | mm (2x 18mm starter) |
| Weight (est.) | ~1492 | g |
| Active area | 286 | cm² (Area) |
| Housing material | AISI 304 | 1.4301 (Inox) |
| Surface finish | Ra < 0.8 µm | Polished |
| Temp. class | 80°C | Standard (N) |
| Force loss (at max °C) | -12.8% | Reversible loss (physics) |
| Force (calculated) | 18.1 | kg (theor.) |
| Induction (surface) | ~8 500 | Gauss (Max) |
Chart 2: Field profile (15 sections)
Chart 3: Temperature performance
Elemental analysis
| iron (Fe) | 64% – 68% |
| neodymium (Nd) | 29% – 32% |
| boron (B) | 1.1% – 1.2% |
| dysprosium (Dy) | 0.5% – 2.0% |
| coating (Ni-Cu-Ni) | < 0.05% |
Environmental data
| recyclability (EoL) | 100% |
| recycled raw materials | ~10% (pre-cons) |
| carbon footprint | low / zredukowany |
| waste code (EWC) | 16 02 16 |
Other products
Strengths as well as weaknesses of neodymium magnets.
Advantages
- They do not lose strength, even after approximately ten years – the decrease in power is only ~1% (according to tests),
- Neodymium magnets are characterized by extremely resistant to demagnetization caused by external field sources,
- A magnet with a smooth nickel surface has better aesthetics,
- Magnets are distinguished by huge magnetic induction on the active area,
- Made from properly selected components, these magnets show impressive resistance to high heat, enabling them to function (depending on their shape) at temperatures up to 230°C and above...
- Thanks to versatility in shaping and the ability to modify to individual projects,
- Key role in modern industrial fields – they are commonly used in computer drives, electric motors, medical devices, as well as complex engineering applications.
- Compactness – despite small sizes they provide effective action, making them ideal for precision applications
Weaknesses
- Susceptibility to cracking is one of their disadvantages. Upon intense impact they can fracture. We advise keeping them in a steel housing, which not only protects them against impacts but also increases their durability
- When exposed to high temperature, neodymium magnets suffer a drop in force. Often, when the temperature exceeds 80°C, their power decreases (depending on the size and shape of the magnet). For those who need magnets for extreme conditions, we offer [AH] versions withstanding up to 230°C
- Due to the susceptibility of magnets to corrosion in a humid environment, we recommend using waterproof magnets made of rubber, plastic or other material immune to moisture, in case of application outdoors
- Due to limitations in creating nuts and complex forms in magnets, we propose using casing - magnetic holder.
- Potential hazard related to microscopic parts of magnets are risky, when accidentally swallowed, which gains importance in the context of child safety. Additionally, tiny parts of these products can disrupt the diagnostic process medical when they are in the body.
- Higher cost of purchase is one of the disadvantages compared to ceramic magnets, especially in budget applications
Holding force characteristics
Maximum holding power of the magnet – what it depends on?
- on a block made of mild steel, perfectly concentrating the magnetic field
- whose thickness equals approx. 10 mm
- with an ideally smooth touching surface
- without the slightest air gap between the magnet and steel
- under axial force vector (90-degree angle)
- at room temperature
Magnet lifting force in use – key factors
- Gap between surfaces – even a fraction of a millimeter of separation (caused e.g. by veneer or dirt) significantly weakens the magnet efficiency, often by half at just 0.5 mm.
- Direction of force – highest force is available only during perpendicular pulling. The shear force of the magnet along the plate is standardly many times smaller (approx. 1/5 of the lifting capacity).
- Substrate thickness – to utilize 100% power, the steel must be sufficiently thick. Paper-thin metal restricts the lifting capacity (the magnet "punches through" it).
- Material type – the best choice is high-permeability steel. Cast iron may attract less.
- Surface condition – ground elements ensure maximum contact, which improves force. Uneven metal weaken the grip.
- Thermal factor – high temperature weakens pulling force. Too high temperature can permanently demagnetize the magnet.
Lifting capacity testing was performed on a smooth plate of suitable thickness, under perpendicular forces, whereas under shearing force the holding force is lower. In addition, even a minimal clearance between the magnet and the plate reduces the load capacity.
Safe handling of NdFeB magnets
Swallowing risk
NdFeB magnets are not intended for children. Swallowing a few magnets may result in them pinching intestinal walls, which poses a direct threat to life and necessitates immediate surgery.
Protect data
Data protection: Strong magnets can damage data carriers and delicate electronics (heart implants, hearing aids, timepieces).
Sensitization to coating
Allergy Notice: The Ni-Cu-Ni coating consists of nickel. If redness occurs, cease working with magnets and use protective gear.
Respect the power
Be careful. Rare earth magnets attract from a distance and connect with massive power, often quicker than you can move away.
Life threat
For implant holders: Powerful magnets affect electronics. Keep minimum 30 cm distance or ask another person to handle the magnets.
Magnet fragility
Protect your eyes. Magnets can fracture upon uncontrolled impact, ejecting shards into the air. Wear goggles.
Thermal limits
Keep cool. Neodymium magnets are susceptible to temperature. If you need operation above 80°C, look for HT versions (H, SH, UH).
Finger safety
Large magnets can smash fingers instantly. Never put your hand betwixt two attracting surfaces.
Fire risk
Powder generated during grinding of magnets is self-igniting. Do not drill into magnets without proper cooling and knowledge.
Magnetic interference
A powerful magnetic field interferes with the operation of compasses in phones and GPS navigation. Maintain magnets close to a smartphone to avoid damaging the sensors.