SM 32x500 [2xM8] / N52 - magnetic separator
magnetic separator
Catalog no 130467
GTIN/EAN: 5906301813385
- Diameter Ø
- 32 mm [±1 mm]
- Height
- 500 mm [±1 mm]
- Weight
- 2770 g
- Magnetic Flux
- ~ 10 000 Gauss [±5%]
How we measure these parameters — certificates and measurements
1270.00 zł net / pcs
1562.10 zł with VAT (23% VAT) / pcs
bulk discounts:
Need more?Frequently asked questions
Which rod should I choose for fine contamination?
Which rod pitch should I choose?
Why does efficiency drop after a few weeks of operation?
Call us now
+48 888 99 98 98
alternatively let us know using
contact form
the contact section.
Specifications and structure of a neodymium magnet can be estimated using our
power calculator.
Order by 14:00 and we’ll ship today!
Product card - SM 32x500 [2xM8] / N52 - magnetic separator
Specification / characteristics - SM 32x500 [2xM8] / N52 - magnetic separator
| properties | values |
|---|---|
| Cat. no. | 130467 |
| GTIN/EAN | 5906301813385 |
| Production/Distribution | Dhit sp. z o.o. |
| Country of origin | Poland / China / Germany |
| Customs code | 85059029 |
| Diameter Ø | 32 mm [±1 mm] |
| Height | 500 mm [±1 mm] |
| Weight | 2770 g |
| Material Type | Stainless steel AISI 304 / A2 |
| Magnetic Flux | ~ 10 000 Gauss [±5%] |
| Size/Mount Quantity | 2xM8 |
| Polarity | circumferential - 19 poles |
| Casing Tube Thickness | 1 mm |
| Manufacturing Tolerance | ±1 mm |
Magnetic properties of material N52
| properties | values | units |
|---|---|---|
| Remanence Br ? | 14.2-14.7 | kGs |
| Remanence Br ? | 1420-1470 | mT |
| Coercivity bHc ? | 10.8-12.5 | kOe |
| Coercivity bHc ? | 860-995 | kA/m |
| Intrinsic coercivity iHc | ≥ 12 | kOe |
| Intrinsic coercivity iHc | ≥ 955 | kA/m |
| Energy product BHmax ? | 48-53 | BH max MGOe |
| Energy product BHmax ? | 380-422 | BH max KJ/m |
| Maximum working temperature ? | ≤ 80 | °C |
Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C
| properties | values | units |
|---|---|---|
| Vickers hardness | ≥550 | Hv |
| Density | ≥7.4 | g/cm3 |
| Curie Temperature TC | 310 | °C |
| Curie Temperature TF | 590 | °F |
| Specific resistance | 150 | μΩ⋅cm |
| Bending strength | 250 | MPa |
| Compressive strength | 1000~1100 | MPa |
| Thermal expansion parallel (∥) to orientation (M) | (3-4) x 10-6 | °C-1 |
| Thermal expansion perpendicular (⊥) to orientation (M) | -(1-3) x 10-6 | °C-1 |
| Young's modulus | 1.7 x 104 | kg/mm² |
Table 1: Rod construction
SM 32x500 [2xM8] / N52
| Parameter | Value | Description / Unit |
|---|---|---|
| Diameter (Ø) | 32 | mm |
| Total length | 500 | mm (L) |
| Active length | 464 | mm |
| Section count | 20 | modules |
| Dead zone | 36 | mm (2x 18mm starter) |
| Weight (est.) | ~3056 | g |
| Active area | 466 | cm² (Area) |
| Housing material | AISI 304 | 1.4301 (Inox) |
| Surface finish | Ra < 0.8 µm | Polished |
| Temp. class | 80°C | Standard (N) |
| Force loss (at max °C) | -12.8% | Reversible loss (physics) |
| Force (calculated) | 41 | kg (theor.) |
| Induction (surface) | ~10 000 | Gauss (Max) |
Chart 2: Field profile (20 sections)
Chart 3: Temperature performance
Elemental analysis
| iron (Fe) | 64% – 68% |
| neodymium (Nd) | 29% – 32% |
| boron (B) | 1.1% – 1.2% |
| dysprosium (Dy) | 0.5% – 2.0% |
| coating (Ni-Cu-Ni) | < 0.05% |
Ecology and recycling (GPSR)
| recyclability (EoL) | 100% |
| recycled raw materials | ~10% (pre-cons) |
| carbon footprint | low / zredukowany |
| waste code (EWC) | 16 02 16 |
Check out more offers
Strengths and weaknesses of rare earth magnets.
Pros
- Their magnetic field is maintained, and after approximately ten years it decreases only by ~1% (according to research),
- Magnets perfectly resist against loss of magnetization caused by external fields,
- Thanks to the reflective finish, the plating of nickel, gold, or silver-plated gives an aesthetic appearance,
- Magnets exhibit very high magnetic induction on the working surface,
- Thanks to resistance to high temperature, they are able to function (depending on the shape) even at temperatures up to 230°C and higher...
- Thanks to versatility in shaping and the capacity to customize to complex applications,
- Key role in electronics industry – they are commonly used in data components, drive modules, precision medical tools, and technologically advanced constructions.
- Thanks to their power density, small magnets offer high operating force, in miniature format,
Disadvantages
- To avoid cracks upon strong impacts, we recommend using special steel holders. Such a solution protects the magnet and simultaneously increases its durability.
- We warn that neodymium magnets can reduce their strength at high temperatures. To prevent this, we advise our specialized [AH] magnets, which work effectively even at 230°C.
- Due to the susceptibility of magnets to corrosion in a humid environment, we suggest using waterproof magnets made of rubber, plastic or other material immune to moisture, when using outdoors
- We suggest a housing - magnetic holder, due to difficulties in producing threads inside the magnet and complicated shapes.
- Health risk to health – tiny shards of magnets are risky, when accidentally swallowed, which becomes key in the context of child safety. Furthermore, small elements of these magnets can complicate diagnosis medical after entering the body.
- Due to complex production process, their price exceeds standard values,
Holding force characteristics
Maximum holding power of the magnet – what it depends on?
- with the use of a yoke made of special test steel, guaranteeing maximum field concentration
- possessing a massiveness of at least 10 mm to avoid saturation
- with an ideally smooth contact surface
- under conditions of no distance (metal-to-metal)
- under axial force direction (90-degree angle)
- at temperature approx. 20 degrees Celsius
Magnet lifting force in use – key factors
- Distance (between the magnet and the plate), as even a microscopic distance (e.g. 0.5 mm) leads to a decrease in lifting capacity by up to 50% (this also applies to paint, corrosion or dirt).
- Load vector – maximum parameter is reached only during perpendicular pulling. The force required to slide of the magnet along the plate is typically several times smaller (approx. 1/5 of the lifting capacity).
- Metal thickness – thin material does not allow full use of the magnet. Magnetic flux passes through the material instead of converting into lifting capacity.
- Chemical composition of the base – low-carbon steel attracts best. Alloy steels lower magnetic permeability and lifting capacity.
- Surface finish – full contact is obtained only on polished steel. Rough texture create air cushions, reducing force.
- Thermal environment – temperature increase causes a temporary drop of induction. Check the maximum operating temperature for a given model.
Holding force was tested on a smooth steel plate of 20 mm thickness, when a perpendicular force was applied, whereas under attempts to slide the magnet the lifting capacity is smaller. In addition, even a minimal clearance between the magnet’s surface and the plate decreases the holding force.
Warnings
Magnetic interference
A powerful magnetic field interferes with the functioning of magnetometers in phones and navigation systems. Maintain magnets close to a device to avoid breaking the sensors.
Immense force
Handle magnets with awareness. Their powerful strength can surprise even experienced users. Stay alert and do not underestimate their power.
Permanent damage
Avoid heat. NdFeB magnets are sensitive to heat. If you need operation above 80°C, ask us about special high-temperature series (H, SH, UH).
Bone fractures
Pinching hazard: The pulling power is so great that it can cause hematomas, crushing, and broken bones. Protective gloves are recommended.
Do not give to children
These products are not toys. Eating multiple magnets may result in them connecting inside the digestive tract, which constitutes a critical condition and necessitates immediate surgery.
Fire risk
Drilling and cutting of NdFeB material poses a fire risk. Neodymium dust reacts violently with oxygen and is hard to extinguish.
Risk of cracking
Beware of splinters. Magnets can explode upon uncontrolled impact, ejecting sharp fragments into the air. Eye protection is mandatory.
Implant safety
Patients with a ICD should keep an large gap from magnets. The magnetism can disrupt the operation of the implant.
Nickel coating and allergies
A percentage of the population have a sensitization to nickel, which is the common plating for neodymium magnets. Extended handling might lead to skin redness. We strongly advise use safety gloves.
Threat to electronics
Do not bring magnets close to a wallet, laptop, or TV. The magnetic field can irreversibly ruin these devices and wipe information from cards.