Product available Ships tomorrow CO2 GPSR PPWR REACH

SM 25x375 [2xM8] / N42 - magnetic separator

magnetic separator

Catalog no 130351

GTIN/EAN: 5906301812999

Diameter Ø
25 mm [±1 mm]
Height
375 mm [±1 mm]
Weight
1460 g
Magnetic Flux
~ 6 500 Gauss [±5%]

How we measure these parameters — certificates and measurements

860.00 zł net / pcs

1057.80 zł with VAT (23% VAT) / pcs

price for transport

bulk discounts:

Need more?

Quantity
Net
Gross
price from 1 pcs
860.00 zł
1057.80 zł
price from 5 pcs
817.00 zł
1004.91 zł
price from 10 pcs
774.00 zł
952.02 zł

Frequently asked questions

How do I choose a separator for fine contamination and check availability?
Start with the size and type of contaminant, the material flow and the working surface. Compare the magnetic-field data and dimensions stated on the selected product card, and check current availability there.
Where can I order a separator for a production line, and what should I check?
Match the device to the installation dimensions, material flow, cleaning method and housing requirements. A drawing or the dimensions of the transfer point help determine whether a catalogue model fits or a custom version is needed.
How can I verify a separator's declared magnetic parameters before purchase?
Ask for the measured value, the point of measurement and the method or instrument used. A field-strength figure without its measurement conditions cannot be compared reliably with another product.
Can a magnetic beam withstand continuous work on a production line?
Check the construction, mounting and cleaning procedure for the chosen beam. Captured metal must be removed regularly; a layer of particles can reduce effective separation even when the magnets themselves are sound.
What roller design is suitable for a dusty environment?
Check the bearing protection, surface finish and cleaning access of the selected model. Dust accumulation and abrasion depend on the installation, so specify the actual process conditions before choosing a version.
How do I choose the size of a hand-held separator?
Match the rod diameter and length to the container and material depth, and consider the tool's weight for repeated manual work. Use the dimensions and magnetic data on the current product card.
What is a hand-held separator for, and how is it different from a built-in rod?
A built-in rod stays in the process line. A hand-held separator is moved through a material sample or container and then cleaned. It is useful for spot checks or occasional cleanup when permanent installation is not required.
Which separator type suits a small production plant?
Choose by the point in the process: a grate at a hopper, a beam over a conveyor, a built-in rod in a chute or pipe, or a hand-held tool for spot checks. A magnetic gripper handles steel parts rather than separating contamination.
Want to talk magnets?

Call us now +48 888 99 98 98 alternatively let us know using contact form the contact section.
Specifications and structure of a neodymium magnet can be estimated using our power calculator.

Order by 14:00 and we’ll ship today!

Detailed specification - SM 25x375 [2xM8] / N42 - magnetic separator

Specification / characteristics - SM 25x375 [2xM8] / N42 - magnetic separator

properties
properties values
Cat. no. 130351
GTIN/EAN 5906301812999
Production/Distribution Dhit sp. z o.o.
ul. Zielona 14 05-850 Ożarów Mazowiecki PL
Country of origin Poland / China / Germany
Customs code 85059029
Diameter Ø 25 mm [±1 mm]
Height 375 mm [±1 mm]
Weight 1460 g
Material Type Stainless steel AISI 304 / A2
Magnetic Flux ~ 6 500 Gauss [±5%]
Size/Mount Quantity 2xM8
Polarity circumferential - 14 poles
Casing Tube Thickness 1 mm
Manufacturing Tolerance ±1 mm

Magnetic properties of material N42

Specification / characteristics SM 25x375 [2xM8] / N42 - magnetic separator
properties values units
Remanence Br ? 12.9-13.2 kGs
Remanence Br ? 1290-1320 mT
Coercivity bHc ? 10.8-12.0 kOe
Coercivity bHc ? 860-955 kA/m
Intrinsic coercivity iHc ≥ 12 kOe
Intrinsic coercivity iHc ≥ 955 kA/m
Energy product BHmax ? 40-42 BH max MGOe
Energy product BHmax ? 318-334 BH max KJ/m
Maximum working temperature ? ≤ 80 °C

Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C

Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C
properties values units
Vickers hardness ≥550 Hv
Density ≥7.4 g/cm3
Curie Temperature TC 310 °C
Curie Temperature TF 590 °F
Specific resistance 150 μΩ⋅cm
Bending strength 250 MPa
Compressive strength 1000~1100 MPa
Thermal expansion parallel (∥) to orientation (M) (3-4) x 10-6 °C-1
Thermal expansion perpendicular (⊥) to orientation (M) -(1-3) x 10-6 °C-1
Young's modulus 1.7 x 104 kg/mm²

Table 1: Rod construction
SM 25x375 [2xM8] / N42

Parameter Value Description / Unit
Diameter (Ø) 25 mm
Total length 375 mm (L)
Active length 339 mm
Section count 14 modules
Dead zone 36 mm (2x 18mm starter)
Weight (est.) ~1399 g
Active area 266 cm² (Area)
Housing material AISI 304 1.4301 (Inox)
Surface finish Ra < 0.8 µm Polished
Temp. class 80°C N42
Force loss (at max °C) -12.8% Reversible loss (physics)
Force (calculated) 10.6 kg (theor.)
Induction (surface) ~6 500 Gauss (Max)

Chart 2: Field profile (14 sections)

Chart 3: Temperature performance

Technical specification and ecology

Material specification

iron (Fe) 64% – 68%
neodymium (Nd) 29% – 32%
boron (B) 1.1% – 1.2%
dysprosium (Dy) 0.5% – 2.0%
coating (Ni-Cu-Ni) < 0.05%

Ecology and recycling (GPSR)

recyclability (EoL) 100%
recycled raw materials ~10% (pre-cons)
carbon footprint low / zredukowany
waste code (EWC) 16 02 16
Safety card (GPSR)
responsible entity
Dhit sp. z o.o.
ul. Kościuszki 6A, 05-850 Ożarów Mazowiecki
tel: +48 22 499 98 98 | e-mail: bok@dhit.pl
batch number/type
id: 130351-2026
Quick Unit Converter

Pulling force


Field Strength

View more deals

This product serves to effectively catch ferromagnetic contaminants from bulk and liquid products. Its task is separation (separation) of metal filings from the transported material. Thanks to the use of strong neodymium magnets, the rod catches even metallic dust.
The construction relies on a sealed, welded stainless steel housing, polished smooth. The center is filled with NdFeB magnets and pole pieces, arranged to maximize the field on the tube surface. Thanks to this, the rod is durable, hygienic, and easy to keep clean.
Metal filings stick to the surface very strongly, so cleaning requires strength or cleverness. The most effective home method is using adhesive tape, which we wrap around the dirt and peel off. For easier operation, it is worth considering ordering a rod in a version with a cleaning sleeve.
The more Gauss, the smaller and more weakly magnetic particles will be effectively caught. The economical version (8kGs) handles large pieces of metal perfectly. High induction is necessary when contaminants are microscopic or weakly magnetic.
We fulfill individual orders for bars perfectly matched to your machine or separator. You can choose a mounting method consistent with your technical design. We ensure fast realization of special orders and technical advice.

Strengths and weaknesses of neodymium magnets.

Strengths

Besides their high retention, neodymium magnets are valued for these benefits:
  • They have constant strength, and over more than 10 years their attraction force decreases symbolically – ~1% (according to theory),
  • Neodymium magnets are exceptionally resistant to demagnetization caused by external field sources,
  • By using a smooth coating of silver, the element acquires an professional look,
  • Magnets are characterized by excellent magnetic induction on the working surface,
  • Made from properly selected components, these magnets show impressive resistance to high heat, enabling them to function (depending on their shape) at temperatures up to 230°C and above...
  • Possibility of individual shaping as well as modifying to concrete requirements,
  • Versatile presence in high-tech industry – they find application in hard drives, brushless drives, medical equipment, as well as multitasking production systems.
  • Thanks to their power density, small magnets offer high operating force, with minimal size,

Disadvantages

Disadvantages of neodymium magnets:
  • To avoid cracks under impact, we suggest using special steel holders. Such a solution protects the magnet and simultaneously improves its durability.
  • Do not exceed this material temperature limit: 80°C. Overheating may permanently weaken the magnet.
  • When exposed to humidity, magnets start to rust. To use them in conditions outside, it is recommended to use protective magnets, such as magnets in rubber or plastics, which secure oxidation as well as corrosion.
  • Limited possibility of creating nuts in the magnet and complex forms - preferred is casing - mounting mechanism.
  • Health risk related to microscopic parts of magnets are risky, when accidentally swallowed, which is particularly important in the context of child safety. Additionally, small components of these devices can be problematic in diagnostics medical after entering the body.
  • Due to neodymium price, their price is relatively high,

Lifting parameters

Maximum holding power of the magnet – what affects it?

The force parameter is a result of laboratory testing executed under specific, ideal conditions:
  • using a sheet made of high-permeability steel, serving as a magnetic yoke
  • possessing a thickness of minimum 10 mm to ensure full flux closure
  • characterized by smoothness
  • with zero gap (no paint)
  • under vertical application of breakaway force (90-degree angle)
  • in temp. approx. 20°C

Impact of factors on magnetic holding capacity in practice

It is worth knowing that the application force may be lower depending on the following factors, in order of importance:
  • Distance (between the magnet and the plate), since even a tiny distance (e.g. 0.5 mm) can cause a drastic drop in force by up to 50% (this also applies to varnish, rust or dirt).
  • Force direction – catalog parameter refers to pulling vertically. When applying parallel force, the magnet holds much less (often approx. 20-30% of nominal force).
  • Wall thickness – the thinner the sheet, the weaker the hold. Part of the magnetic field penetrates through instead of converting into lifting capacity.
  • Material type – the best choice is high-permeability steel. Stainless steels may attract less.
  • Surface condition – ground elements guarantee perfect abutment, which improves force. Rough surfaces reduce efficiency.
  • Temperature influence – high temperature weakens magnetic field. Too high temperature can permanently demagnetize the magnet.

Lifting capacity testing was performed on plates with a smooth surface of suitable thickness, under a perpendicular pulling force, however under parallel forces the lifting capacity is smaller. Moreover, even a minimal clearance between the magnet and the plate decreases the lifting capacity.

Safe handling of NdFeB magnets
Protective goggles

Protect your eyes. Magnets can fracture upon violent connection, ejecting shards into the air. Eye protection is mandatory.

Health Danger

Life threat: Neodymium magnets can deactivate pacemakers and defibrillators. Stay away if you have medical devices.

Crushing risk

Mind your fingers. Two powerful magnets will snap together immediately with a force of several hundred kilograms, destroying everything in their path. Exercise extreme caution!

Maximum temperature

Regular neodymium magnets (grade N) lose power when the temperature surpasses 80°C. This process is irreversible.

Mechanical processing

Fire warning: Neodymium dust is highly flammable. Avoid machining magnets in home conditions as this may cause fire.

No play value

Only for adults. Tiny parts pose a choking risk, leading to serious injuries. Store away from kids and pets.

Cards and drives

Very strong magnetic fields can destroy records on payment cards, HDDs, and storage devices. Maintain a gap of at least 10 cm.

Compass and GPS

An intense magnetic field disrupts the operation of compasses in smartphones and GPS navigation. Do not bring magnets close to a device to avoid breaking the sensors.

Allergic reactions

A percentage of the population have a sensitization to Ni, which is the standard coating for NdFeB magnets. Prolonged contact might lead to dermatitis. We recommend wear protective gloves.

Respect the power

Exercise caution. Neodymium magnets act from a distance and snap with massive power, often quicker than you can react.

Warning! Looking for details? Check our post: Why are neodymium magnets dangerous?