Product available Ships today (order by 14:00) CO2 GPSR PPWR REACH

SM 25x225 [2xM8] / N52 - magnetic separator

magnetic separator

Catalog no 130354

GTIN/EAN: 5906301813026

5.00
Diameter Ø
25 mm [±1 mm]
Height
225 mm [±1 mm]
Weight
860 g
Magnetic Flux
~ 8 500 Gauss [±5%]

How we measure these parameters — certificates and measurements

560.00net / pcs

688.80 zł with VAT (23% VAT) / pcs

price for transport

bulk discounts:

Need more?

Quantity
Net
Gross
price from 1 pcs
560.00 zł
688.80 zł
price from 5 pcs
532.00 zł
654.36 zł
price from 10 pcs
504.00 zł
619.92 zł

Frequently asked questions

Which rod should I choose for fine contamination?
For particles below 0.5 mm — a Ø32 mm rod in grade N52, with surface induction of about 10,000 Gs. A Ø25 rod in grade N42 gives about 6,500 Gs and is chosen for contamination above 1 mm: bolts, washers, pieces of wire.
Which rod pitch should I choose?
The narrow pitch, 40 mm centre to centre, for fine free-flowing fractions — it gives denser coverage of the cross-section. The wide pitch, 50 mm, for granulates and for damp, greasy or sticky materials, where a narrow pitch risks the material bridging above the rods.
Why does efficiency drop after a few weeks of operation?
Almost always because the separator has not been cleaned. The layer of captured particles shields the field, and further particles settle on that layer rather than on the rod surface, where the gradient is far stronger. The magnets themselves do not weaken at that rate.
Want to talk magnets?

Call us now +48 888 99 98 98 alternatively let us know using contact form the contact section.
Specifications and structure of a neodymium magnet can be estimated using our power calculator.

Order by 14:00 and we’ll ship today!

Technical specification of the product - SM 25x225 [2xM8] / N52 - magnetic separator

Specification / characteristics - SM 25x225 [2xM8] / N52 - magnetic separator

properties
properties values
Cat. no. 130354
GTIN/EAN 5906301813026
Production/Distribution Dhit sp. z o.o.
ul. Zielona 14 05-850 Ożarów Mazowiecki PL
Country of origin Poland / China / Germany
Customs code 85059029
Diameter Ø 25 mm [±1 mm]
Height 225 mm [±1 mm]
Weight 860 g
Material Type Stainless steel AISI 304 / A2
Magnetic Flux ~ 8 500 Gauss [±5%]
Size/Mount Quantity M8x2
Polarity circumferential - 8 poles
Casing Tube Thickness 1 mm
Manufacturing Tolerance ±1 mm

Magnetic properties of material N52

Specification / characteristics SM 25x225 [2xM8] / N52 - magnetic separator
properties values units
Remanence Br ? 14.2-14.7 kGs
Remanence Br ? 1420-1470 mT
Coercivity bHc ? 10.8-12.5 kOe
Coercivity bHc ? 860-995 kA/m
Intrinsic coercivity iHc ≥ 12 kOe
Intrinsic coercivity iHc ≥ 955 kA/m
Energy product BHmax ? 48-53 BH max MGOe
Energy product BHmax ? 380-422 BH max KJ/m
Maximum working temperature ? ≤ 80 °C

Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C

Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C
properties values units
Vickers hardness ≥550 Hv
Density ≥7.4 g/cm3
Curie Temperature TC 310 °C
Curie Temperature TF 590 °F
Specific resistance 150 μΩ⋅cm
Bending strength 250 MPa
Compressive strength 1000~1100 MPa
Thermal expansion parallel (∥) to orientation (M) (3-4) x 10-6 °C-1
Thermal expansion perpendicular (⊥) to orientation (M) -(1-3) x 10-6 °C-1
Young's modulus 1.7 x 104 kg/mm²

Table 1: Rod construction
SM 25x225 [2xM8] / N52

Parameter Value Description / Unit
Diameter (Ø) 25 mm
Total length 225 mm (L)
Active length 189 mm
Section count 8 modules
Dead zone 36 mm (2x 18mm starter)
Weight (est.) ~839 g
Active area 148 cm² (Area)
Housing material AISI 304 1.4301 (Inox)
Surface finish Ra < 0.8 µm Polished
Temp. class 80°C Standard (N)
Force loss (at max °C) -12.8% Reversible loss (physics)
Force (calculated) 18.1 kg (theor.)
Induction (surface) ~8 500 Gauss (Max)

Chart 2: Field profile (8 sections)

Chart 3: Temperature performance

Engineering data and GPSR

Chemical composition

iron (Fe) 64% – 68%
neodymium (Nd) 29% – 32%
boron (B) 1.1% – 1.2%
dysprosium (Dy) 0.5% – 2.0%
coating (Ni-Cu-Ni) < 0.05%

Environmental data

recyclability (EoL) 100%
recycled raw materials ~10% (pre-cons)
carbon footprint low / zredukowany
waste code (EWC) 16 02 16
Safety card (GPSR)
responsible entity
Dhit sp. z o.o.
ul. Kościuszki 6A, 05-850 Ożarów Mazowiecki
tel: +48 22 499 98 98 | e-mail: bok@dhit.pl
batch number/type
id: 130354-2026
Magnet Unit Converter

Force (pull)


Magnetic Induction

View also proposals

This product serves to effectively catch ferromagnetic contaminants from bulk and liquid products. It is mounted in chutes, hoppers, and pipelines to protect production machines from failure. High magnetic induction on the surface allows catching the finest iron particles.
The rod consists of a cover tube made of high-quality acid-resistant steel (AISI 304 or 316). The core is a precise magnetic system generating high induction (Gauss). Such construction ensures full resistance to corrosion, water, oils, and acids.
Due to the high power of the magnet, direct removal of filings can be troublesome and time-consuming. We recommend sticking packing tape to the cluster of filings and tearing it off together with the contaminants. For easier operation, it is worth considering ordering a rod in a version with a cleaning sleeve.
The Gauss value tells us how effectively and deeply the magnet will catch contaminants. For basic machine protection against pieces of iron, standard power is sufficient. High induction is necessary when contaminants are microscopic or weakly magnetic.
We can produce a rod of non-standard length with any mounting termination. The rod end is strictly adapted to the fastening system in your device. We ensure fast realization of special orders and technical advice.

Pros and cons of Nd2Fe14B magnets.

Pros

Apart from their strong holding force, neodymium magnets have these key benefits:
  • They virtually do not lose power, because even after 10 years the performance loss is only ~1% (according to literature),
  • Magnets very well resist against demagnetization caused by foreign field sources,
  • The use of an elegant coating of noble metals (nickel, gold, silver) causes the element to look better,
  • Magnets have very high magnetic induction on the surface,
  • Neodymium magnets are characterized by very high magnetic induction on the magnet surface and can work (depending on the form) even at a temperature of 230°C or more...
  • Possibility of detailed forming as well as adjusting to defined requirements,
  • Huge importance in electronics industry – they are utilized in magnetic memories, drive modules, medical devices, and technologically advanced constructions.
  • Compactness – despite small sizes they provide effective action, making them ideal for precision applications

Limitations

Characteristics of disadvantages of neodymium magnets and proposals for their use:
  • At strong impacts they can crack, therefore we advise placing them in steel cases. A metal housing provides additional protection against damage and increases the magnet's durability.
  • Neodymium magnets lose strength when exposed to high temperatures. After reaching 80°C, many of them experience permanent drop of power (a factor is the shape as well as dimensions of the magnet). We offer magnets specially adapted to work at temperatures up to 230°C marked [AH], which are very resistant to heat
  • When exposed to humidity, magnets start to rust. To use them in conditions outside, it is recommended to use protective magnets, such as those in rubber or plastics, which prevent oxidation and corrosion.
  • We suggest a housing - magnetic mount, due to difficulties in creating nuts inside the magnet and complicated forms.
  • Possible danger to health – tiny shards of magnets are risky, when accidentally swallowed, which becomes key in the context of child health protection. It is also worth noting that tiny parts of these magnets can be problematic in diagnostics medical in case of swallowing.
  • Due to neodymium price, their price is relatively high,

Pull force analysis

Optimal lifting capacity of a neodymium magnetwhat affects it?

Information about lifting capacity was defined for the most favorable conditions, including:
  • on a plate made of structural steel, perfectly concentrating the magnetic field
  • whose thickness equals approx. 10 mm
  • with a plane cleaned and smooth
  • without the slightest air gap between the magnet and steel
  • for force acting at a right angle (in the magnet axis)
  • in neutral thermal conditions

What influences lifting capacity in practice

In practice, the actual lifting capacity results from a number of factors, listed from crucial:
  • Space between magnet and steel – even a fraction of a millimeter of distance (caused e.g. by varnish or dirt) significantly weakens the magnet efficiency, often by half at just 0.5 mm.
  • Angle of force application – highest force is reached only during pulling at a 90° angle. The force required to slide of the magnet along the plate is standardly several times smaller (approx. 1/5 of the lifting capacity).
  • Metal thickness – thin material does not allow full use of the magnet. Part of the magnetic field penetrates through instead of converting into lifting capacity.
  • Steel grade – the best choice is high-permeability steel. Stainless steels may attract less.
  • Surface finish – full contact is possible only on polished steel. Rough texture reduce the real contact area, reducing force.
  • Thermal factor – high temperature weakens magnetic field. Too high temperature can permanently damage the magnet.

Holding force was tested on a smooth steel plate of 20 mm thickness, when the force acted perpendicularly, in contrast under shearing force the load capacity is reduced by as much as 5 times. In addition, even a small distance between the magnet and the plate lowers the lifting capacity.

H&S for magnets
Pacemakers

For implant holders: Strong magnetic fields disrupt electronics. Keep minimum 30 cm distance or request help to handle the magnets.

Compass and GPS

GPS units and mobile phones are extremely sensitive to magnetism. Close proximity with a powerful NdFeB magnet can decalibrate the internal compass in your phone.

Caution required

Before use, check safety instructions. Sudden snapping can destroy the magnet or hurt your hand. Think ahead.

Finger safety

Large magnets can crush fingers in a fraction of a second. Never place your hand betwixt two attracting surfaces.

Nickel allergy

Certain individuals suffer from a hypersensitivity to Ni, which is the standard coating for neodymium magnets. Prolonged contact may cause skin redness. It is best to use safety gloves.

Mechanical processing

Machining of NdFeB material poses a fire risk. Neodymium dust reacts violently with oxygen and is difficult to extinguish.

Danger to the youngest

Only for adults. Tiny parts can be swallowed, causing severe trauma. Store away from children and animals.

Material brittleness

Beware of splinters. Magnets can fracture upon violent connection, launching shards into the air. Wear goggles.

Permanent damage

Regular neodymium magnets (N-type) lose magnetization when the temperature surpasses 80°C. This process is irreversible.

Keep away from computers

Device Safety: Strong magnets can damage data carriers and sensitive devices (heart implants, hearing aids, timepieces).

Safety First! Want to know more? Check our post: Are neodymium magnets dangerous?