SM 25x150 [2xM8] / N52 - magnetic separator
magnetic separator
Catalog no 130368
GTIN/EAN: 5906301813163
- Diameter Ø
- 25 mm [±1 mm]
- Height
- 150 mm [±1 mm]
- Weight
- 560 g
- Magnetic Flux
- ~ 8 500 Gauss [±5%]
How we measure these parameters — certificates and measurements
400.00 zł net / pcs
492.00 zł with VAT (23% VAT) / pcs
bulk discounts:
Need more?Frequently asked questions
Which rod should I choose for fine contamination?
Which rod pitch should I choose?
Why does efficiency drop after a few weeks of operation?
Call us now
+48 888 99 98 98
alternatively let us know using
contact form
the contact section.
Specifications and structure of a neodymium magnet can be estimated using our
power calculator.
Order by 14:00 and we’ll ship today!
Technical specification - SM 25x150 [2xM8] / N52 - magnetic separator
Specification / characteristics - SM 25x150 [2xM8] / N52 - magnetic separator
| properties | values |
|---|---|
| Cat. no. | 130368 |
| GTIN/EAN | 5906301813163 |
| Production/Distribution | Dhit sp. z o.o. |
| Country of origin | Poland / China / Germany |
| Customs code | 85059029 |
| Diameter Ø | 25 mm [±1 mm] |
| Height | 150 mm [±1 mm] |
| Weight | 560 g |
| Material Type | Stainless steel AISI 304 / A2 |
| Magnetic Flux | ~ 8 500 Gauss [±5%] |
| Size/Mount Quantity | M8x2 |
| Polarity | circumferential - 5 poles |
| Casing Tube Thickness | 1 mm |
| Manufacturing Tolerance | ±1 mm |
Magnetic properties of material N52
| properties | values | units |
|---|---|---|
| Remanence Br ? | 14.2-14.7 | kGs |
| Remanence Br ? | 1420-1470 | mT |
| Coercivity bHc ? | 10.8-12.5 | kOe |
| Coercivity bHc ? | 860-995 | kA/m |
| Intrinsic coercivity iHc | ≥ 12 | kOe |
| Intrinsic coercivity iHc | ≥ 955 | kA/m |
| Energy product BHmax ? | 48-53 | BH max MGOe |
| Energy product BHmax ? | 380-422 | BH max KJ/m |
| Maximum working temperature ? | ≤ 80 | °C |
Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C
| properties | values | units |
|---|---|---|
| Vickers hardness | ≥550 | Hv |
| Density | ≥7.4 | g/cm3 |
| Curie Temperature TC | 310 | °C |
| Curie Temperature TF | 590 | °F |
| Specific resistance | 150 | μΩ⋅cm |
| Bending strength | 250 | MPa |
| Compressive strength | 1000~1100 | MPa |
| Thermal expansion parallel (∥) to orientation (M) | (3-4) x 10-6 | °C-1 |
| Thermal expansion perpendicular (⊥) to orientation (M) | -(1-3) x 10-6 | °C-1 |
| Young's modulus | 1.7 x 104 | kg/mm² |
Table 1: Rod construction
SM 25x150 [2xM8] / N52
| Parameter | Value | Description / Unit |
|---|---|---|
| Diameter (Ø) | 25 | mm |
| Total length | 150 | mm (L) |
| Active length | 114 | mm |
| Section count | 4 | modules |
| Dead zone | 36 | mm (2x 18mm starter) |
| Weight (est.) | ~560 | g |
| Active area | 90 | cm² (Area) |
| Housing material | AISI 304 | 1.4301 (Inox) |
| Surface finish | Ra < 0.8 µm | Polished |
| Temp. class | 80°C | Standard (N) |
| Force loss (at max °C) | -12.8% | Reversible loss (physics) |
| Force (calculated) | 18.1 | kg (theor.) |
| Induction (surface) | ~8 500 | Gauss (Max) |
Chart 2: Field profile (4 sections)
Chart 3: Temperature performance
Material specification
| iron (Fe) | 64% – 68% |
| neodymium (Nd) | 29% – 32% |
| boron (B) | 1.1% – 1.2% |
| dysprosium (Dy) | 0.5% – 2.0% |
| coating (Ni-Cu-Ni) | < 0.05% |
Ecology and recycling (GPSR)
| recyclability (EoL) | 100% |
| recycled raw materials | ~10% (pre-cons) |
| carbon footprint | low / zredukowany |
| waste code (EWC) | 16 02 16 |
Other proposals
Advantages as well as disadvantages of rare earth magnets.
Strengths
- They retain magnetic properties for nearly 10 years – the loss is just ~1% (based on simulations),
- They feature excellent resistance to magnetic field loss when exposed to external magnetic sources,
- Thanks to the shiny finish, the coating of Ni-Cu-Ni, gold, or silver gives an visually attractive appearance,
- Magnetic induction on the surface of the magnet turns out to be impressive,
- Thanks to resistance to high temperature, they can operate (depending on the shape) even at temperatures up to 230°C and higher...
- Possibility of detailed machining as well as adjusting to atypical requirements,
- Universal use in electronics industry – they serve a role in computer drives, electric drive systems, medical equipment, as well as complex engineering applications.
- Relatively small size with high pulling force – neodymium magnets offer high power in small dimensions, which allows their use in compact constructions
Weaknesses
- At very strong impacts they can crack, therefore we advise placing them in steel cases. A metal housing provides additional protection against damage and increases the magnet's durability.
- We warn that neodymium magnets can lose their strength at high temperatures. To prevent this, we suggest our specialized [AH] magnets, which work effectively even at 230°C.
- Due to the susceptibility of magnets to corrosion in a humid environment, we recommend using waterproof magnets made of rubber, plastic or other material stable to moisture, in case of application outdoors
- Limited ability of producing nuts in the magnet and complicated forms - recommended is casing - magnetic holder.
- Health risk related to microscopic parts of magnets are risky, in case of ingestion, which is particularly important in the context of child health protection. Furthermore, tiny parts of these magnets are able to complicate diagnosis medical in case of swallowing.
- Higher cost of purchase is one of the disadvantages compared to ceramic magnets, especially in budget applications
Lifting parameters
Breakaway strength of the magnet in ideal conditions – what affects it?
- with the application of a sheet made of low-carbon steel, guaranteeing full magnetic saturation
- whose thickness equals approx. 10 mm
- characterized by smoothness
- without any clearance between the magnet and steel
- for force applied at a right angle (pull-off, not shear)
- at temperature room level
Key elements affecting lifting force
- Clearance – existence of any layer (rust, dirt, air) interrupts the magnetic circuit, which reduces capacity steeply (even by 50% at 0.5 mm).
- Force direction – note that the magnet has greatest strength perpendicularly. Under shear forces, the capacity drops drastically, often to levels of 20-30% of the nominal value.
- Plate thickness – too thin sheet causes magnetic saturation, causing part of the power to be escaped into the air.
- Metal type – not every steel reacts the same. High carbon content weaken the attraction effect.
- Surface condition – ground elements ensure maximum contact, which improves force. Rough surfaces weaken the grip.
- Thermal conditions – neodymium magnets have a sensitivity to temperature. When it is hot they lose power, and at low temperatures gain strength (up to a certain limit).
Lifting capacity testing was conducted on a smooth plate of optimal thickness, under a perpendicular pulling force, however under attempts to slide the magnet the holding force is lower. Moreover, even a small distance between the magnet and the plate lowers the holding force.
H&S for magnets
Sensitization to coating
Allergy Notice: The Ni-Cu-Ni coating contains nickel. If an allergic reaction appears, immediately stop handling magnets and wear gloves.
Precision electronics
GPS units and mobile phones are highly sensitive to magnetism. Direct contact with a strong magnet can permanently damage the sensors in your phone.
Respect the power
Before use, read the rules. Uncontrolled attraction can destroy the magnet or injure your hand. Think ahead.
Implant safety
For implant holders: Powerful magnets disrupt electronics. Maintain minimum 30 cm distance or request help to handle the magnets.
Magnetic media
Device Safety: Neodymium magnets can damage data carriers and delicate electronics (pacemakers, medical aids, timepieces).
Protective goggles
NdFeB magnets are sintered ceramics, which means they are fragile like glass. Impact of two magnets will cause them shattering into shards.
Heat sensitivity
Monitor thermal conditions. Heating the magnet to high heat will ruin its properties and pulling force.
Serious injuries
Pinching hazard: The pulling power is so great that it can result in blood blisters, pinching, and even bone fractures. Use thick gloves.
Dust is flammable
Dust produced during machining of magnets is combustible. Avoid drilling into magnets without proper cooling and knowledge.
Keep away from children
Strictly keep magnets out of reach of children. Ingestion danger is significant, and the effects of magnets clamping inside the body are tragic.