SM 18x225 [2xM5] / N42 - magnetic separator
magnetic separator
Catalog no 130274
GTIN/EAN: 5906301812760
- Diameter Ø
- 18 mm [±1 mm]
- Height
- 225 mm [±1 mm]
- Weight
- 0.01 g
- Magnetic Flux
- ~ 5 400 Gauss [±5%]
How we measure these parameters — certificates and measurements
405.00 zł net / pcs
498.15 zł with VAT (23% VAT) / pcs
bulk discounts:
Need more?Frequently asked questions
Which rod should I choose for fine contamination?
Which rod pitch should I choose?
Why does efficiency drop after a few weeks of operation?
Call us now
+48 888 99 98 98
alternatively let us know using
contact form
the contact section.
Specifications and structure of a neodymium magnet can be estimated using our
power calculator.
Order by 14:00 and we’ll ship today!
Technical specification - SM 18x225 [2xM5] / N42 - magnetic separator
Specification / characteristics - SM 18x225 [2xM5] / N42 - magnetic separator
| properties | values |
|---|---|
| Cat. no. | 130274 |
| GTIN/EAN | 5906301812760 |
| Production/Distribution | Dhit sp. z o.o. |
| Country of origin | Poland / China / Germany |
| Customs code | 85059029 |
| Diameter Ø | 18 mm [±1 mm] |
| Height | 225 mm [±1 mm] |
| Weight | 0.01 g |
| Material Type | Stainless steel AISI 304 / A2 |
| Magnetic Flux | ~ 5 400 Gauss [±5%] |
| Size/Mount Quantity | 2xM5 |
| Polarity | circumferential - 10 poles |
| Casing Tube Thickness | 1 mm |
| Manufacturing Tolerance | ±1 mm |
Magnetic properties of material N42
| properties | values | units |
|---|---|---|
| Remanence Br ? | 12.9-13.2 | kGs |
| Remanence Br ? | 1290-1320 | mT |
| Coercivity bHc ? | 10.8-12.0 | kOe |
| Coercivity bHc ? | 860-955 | kA/m |
| Intrinsic coercivity iHc | ≥ 12 | kOe |
| Intrinsic coercivity iHc | ≥ 955 | kA/m |
| Energy product BHmax ? | 40-42 | BH max MGOe |
| Energy product BHmax ? | 318-334 | BH max KJ/m |
| Maximum working temperature ? | ≤ 80 | °C |
Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C
| properties | values | units |
|---|---|---|
| Vickers hardness | ≥550 | Hv |
| Density | ≥7.4 | g/cm3 |
| Curie Temperature TC | 310 | °C |
| Curie Temperature TF | 590 | °F |
| Specific resistance | 150 | μΩ⋅cm |
| Bending strength | 250 | MPa |
| Compressive strength | 1000~1100 | MPa |
| Thermal expansion parallel (∥) to orientation (M) | (3-4) x 10-6 | °C-1 |
| Thermal expansion perpendicular (⊥) to orientation (M) | -(1-3) x 10-6 | °C-1 |
| Young's modulus | 1.7 x 104 | kg/mm² |
Table 1: Rod construction
SM 18x225 [2xM5] / N42
| Parameter | Value | Description / Unit |
|---|---|---|
| Diameter (Ø) | 18 | mm |
| Total length | 225 | mm (L) |
| Active length | 189 | mm |
| Section count | 8 | modules |
| Dead zone | 36 | mm (2x 18mm starter) |
| Weight (est.) | ~435 | g |
| Active area | 107 | cm² (Area) |
| Housing material | AISI 304 | 1.4301 (Inox) |
| Surface finish | Ra < 0.8 µm | Polished |
| Temp. class | 80°C | Standard (N) |
| Force loss (at max °C) | -12.8% | Reversible loss (physics) |
| Force (calculated) | 3.8 | kg (theor.) |
| Induction (surface) | ~5 400 | Gauss (Max) |
Chart 2: Field profile (8 sections)
Chart 3: Temperature performance
Material specification
| iron (Fe) | 64% – 68% |
| neodymium (Nd) | 29% – 32% |
| boron (B) | 1.1% – 1.2% |
| dysprosium (Dy) | 0.5% – 2.0% |
| coating (Ni-Cu-Ni) | < 0.05% |
Environmental data
| recyclability (EoL) | 100% |
| recycled raw materials | ~10% (pre-cons) |
| carbon footprint | low / zredukowany |
| waste code (EWC) | 16 02 16 |
Other deals
Pros as well as cons of rare earth magnets.
Strengths
- They virtually do not lose power, because even after 10 years the decline in efficiency is only ~1% (based on calculations),
- They are extremely resistant to demagnetization induced by external magnetic fields,
- By using a reflective coating of nickel, the element acquires an proper look,
- Magnets are characterized by extremely high magnetic induction on the outer side,
- Neodymium magnets are characterized by very high magnetic induction on the magnet surface and can work (depending on the shape) even at a temperature of 230°C or more...
- In view of the ability of accurate forming and adaptation to specialized needs, magnetic components can be manufactured in a broad palette of geometric configurations, which amplifies use scope,
- Universal use in innovative solutions – they are commonly used in hard drives, electric motors, precision medical tools, and multitasking production systems.
- Thanks to efficiency per cm³, small magnets offer high operating force, with minimal size,
Cons
- They are prone to damage upon too strong impacts. To avoid cracks, it is worth securing magnets in special housings. Such protection not only shields the magnet but also improves its resistance to damage
- Neodymium magnets decrease their power under the influence of heating. As soon as 80°C is exceeded, many of them start losing their force. Therefore, we recommend our special magnets marked [AH], which maintain stability even at temperatures up to 230°C
- They rust in a humid environment. For use outdoors we advise using waterproof magnets e.g. in rubber, plastic
- Due to limitations in creating nuts and complex forms in magnets, we propose using a housing - magnetic mount.
- Potential hazard related to microscopic parts of magnets pose a threat, when accidentally swallowed, which becomes key in the aspect of protecting the youngest. Furthermore, small components of these products can disrupt the diagnostic process medical after entering the body.
- Due to complex production process, their price is higher than average,
Holding force characteristics
Maximum lifting capacity of the magnet – what contributes to it?
- using a base made of high-permeability steel, functioning as a ideal flux conductor
- possessing a thickness of at least 10 mm to avoid saturation
- characterized by smoothness
- under conditions of gap-free contact (surface-to-surface)
- for force acting at a right angle (pull-off, not shear)
- in neutral thermal conditions
Determinants of practical lifting force of a magnet
- Gap (betwixt the magnet and the plate), since even a microscopic distance (e.g. 0.5 mm) can cause a reduction in force by up to 50% (this also applies to varnish, rust or dirt).
- Pull-off angle – note that the magnet has greatest strength perpendicularly. Under sliding down, the capacity drops significantly, often to levels of 20-30% of the maximum value.
- Substrate thickness – for full efficiency, the steel must be sufficiently thick. Paper-thin metal limits the lifting capacity (the magnet "punches through" it).
- Metal type – not every steel reacts the same. Alloy additives weaken the interaction with the magnet.
- Surface structure – the more even the surface, the better the adhesion and stronger the hold. Unevenness acts like micro-gaps.
- Temperature influence – hot environment reduces magnetic field. Exceeding the limit temperature can permanently demagnetize the magnet.
Lifting capacity was assessed using a smooth steel plate of optimal thickness (min. 20 mm), under vertically applied force, however under shearing force the lifting capacity is smaller. Moreover, even a small distance between the magnet and the plate decreases the holding force.
H&S for magnets
Nickel allergy
It is widely known that the nickel plating (standard magnet coating) is a common allergen. For allergy sufferers, refrain from direct skin contact or select versions in plastic housing.
Health Danger
Patients with a pacemaker have to maintain an large gap from magnets. The magnetic field can interfere with the functioning of the implant.
Handling guide
Before use, read the rules. Uncontrolled attraction can break the magnet or injure your hand. Be predictive.
Magnetic media
Avoid bringing magnets close to a wallet, laptop, or screen. The magnetism can irreversibly ruin these devices and erase data from cards.
Hand protection
Risk of injury: The attraction force is so immense that it can result in blood blisters, pinching, and even bone fractures. Use thick gloves.
Magnetic interference
Remember: neodymium magnets produce a field that interferes with precision electronics. Keep a separation from your phone, device, and navigation systems.
Heat warning
Do not overheat. Neodymium magnets are susceptible to temperature. If you need operation above 80°C, look for HT versions (H, SH, UH).
Machining danger
Machining of NdFeB material carries a risk of fire hazard. Magnetic powder oxidizes rapidly with oxygen and is hard to extinguish.
Protective goggles
Despite the nickel coating, the material is brittle and cannot withstand shocks. Avoid impacts, as the magnet may shatter into sharp, dangerous pieces.
Adults only
NdFeB magnets are not suitable for play. Swallowing multiple magnets can lead to them connecting inside the digestive tract, which poses a direct threat to life and requires urgent medical intervention.