SM 28x175 [2xM8] / N52 - magnetic separator

magnetic separator

Catalog no 130520

Diameter Ø
28 mm [±1 mm]
Height
175 mm [±1 mm]
Weight
827.9 g
Magnetic Flux
~ 8 500 Gauss [±5%]

How we measure these parameters — certificates and measurements

470.00net / pcs

578.10 zł with VAT (23% VAT) / pcs

price for transport

bulk discounts:

Need more?

Quantity
Net
Gross
price from 1 pcs
470.00 zł
578.10 zł
price from 10 pcs
423.00 zł
520.29 zł

Frequently asked questions

Which rod should I choose for fine contamination?
For particles below 0.5 mm — a Ø32 mm rod in grade N52, with surface induction of about 10,000 Gs. A Ø25 rod in grade N42 gives about 6,500 Gs and is chosen for contamination above 1 mm: bolts, washers, pieces of wire.
Which rod pitch should I choose?
The narrow pitch, 40 mm centre to centre, for fine free-flowing fractions — it gives denser coverage of the cross-section. The wide pitch, 50 mm, for granulates and for damp, greasy or sticky materials, where a narrow pitch risks the material bridging above the rods.
Why does efficiency drop after a few weeks of operation?
Almost always because the separator has not been cleaned. The layer of captured particles shields the field, and further particles settle on that layer rather than on the rod surface, where the gradient is far stronger. The magnets themselves do not weaken at that rate.
Want to talk magnets?

Call us now +48 888 99 98 98 alternatively let us know using contact form the contact section.
Specifications and structure of a neodymium magnet can be estimated using our power calculator.

Order by 14:00 and we’ll ship today!

Technical parameters of the product - SM 28x175 [2xM8] / N52 - magnetic separator

Specification / characteristics - SM 28x175 [2xM8] / N52 - magnetic separator

properties
properties values
Cat. no. 130520
Production/Distribution Dhit sp. z o.o.
ul. Zielona 14 05-850 Ożarów Mazowiecki PL
Country of origin Poland / China / Germany
Customs code 85059029
Diameter Ø 28 mm [±1 mm]
Height 175 mm [±1 mm]
Weight 827.9 g
Material Type Stainless steel AISI 304 / A2
Magnetic Flux ~ 8 500 Gauss [±5%]
Size/Mount Quantity M8x2
Polarity circumferential - 6 poles
Casing Tube Thickness 1 mm
Manufacturing Tolerance ±1 mm

Magnetic properties of material N52

Specification / characteristics SM 28x175 [2xM8] / N52 - magnetic separator
properties values units
remenance Br [min. - max.] ? 14.2-14.7 kGs
remenance Br [min. - max.] ? 1420-1470 mT
coercivity bHc ? 10.8-12.5 kOe
coercivity bHc ? 860-995 kA/m
actual internal force iHc ≥ 12 kOe
actual internal force iHc ≥ 955 kA/m
energy density [min. - max.] ? 48-53 BH max MGOe
energy density [min. - max.] ? 380-422 BH max KJ/m
max. temperature ? ≤ 80 °C

Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C

Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C
properties values units
Vickers hardness ≥550 Hv
Density ≥7.4 g/cm3
Curie Temperature TC 310 °C
Curie Temperature TF 590 °F
Specific resistance 150 μΩ⋅cm
Bending strength 250 MPa
Compressive strength 1000~1100 MPa
Thermal expansion parallel (∥) to orientation (M) (3-4) x 10-6 °C-1
Thermal expansion perpendicular (⊥) to orientation (M) -(1-3) x 10-6 °C-1
Young's modulus 1.7 x 104 kg/mm²

Table 1: Rod construction
SM 28x175 [2xM8] / N52

Parameter Value Description / Unit
Diameter (Ø) 28 mm
Total length 175 mm (L)
Active length 139 mm
Section count 6 modules
Dead zone 36 mm (2x 18mm starter)
Weight (est.) ~819 g
Active area 122 cm² (Area)
Housing material AISI 304 1.4301 (Inox)
Surface finish Ra < 0.8 µm Polished
Temp. class 80°C Standard (N)
Force loss (at max °C) -12.8% Reversible loss (physics)
Force (calculated) 22.7 kg (theor.)
Induction (surface) ~8 500 Gauss (Max)

Chart 2: Field profile (6 sections)

Chart 3: Temperature performance

Technical and environmental data

Elemental analysis

iron (Fe) 64% – 68%
neodymium (Nd) 29% – 32%
boron (B) 1.1% – 1.2%
dysprosium (Dy) 0.5% – 2.0%
coating (Ni-Cu-Ni) < 0.05%

Sustainability

recyclability (EoL) 100%
recycled raw materials ~10% (pre-cons)
carbon footprint low / zredukowany
waste code (EWC) 16 02 16
Safety card (GPSR)
responsible entity
Dhit sp. z o.o.
ul. Kościuszki 6A, 05-850 Ożarów Mazowiecki
tel: +48 22 499 98 98 | e-mail: bok@dhit.pl
batch number/type
id: 130520-2026
Magnet Unit Converter

Pulling force


Magnetic Field

Other proposals

It is the "heart" of every magnetic filter used in industry for cleaning raw materials. It is mounted in chutes, hoppers, and pipelines to protect production machines from failure. Thanks to the use of strong neodymium magnets, the rod catches even metallic dust.
The rod consists of a cover tube made of high-quality acid-resistant steel (AISI 304 or 316). The center is filled with NdFeB magnets and pole pieces, arranged to maximize the field on the tube surface. Thanks to this, the rod is durable, hygienic, and easy to keep clean.
Metal contaminants are strongly attracted, so removing them with a bare hand or glove can be difficult. We recommend sticking packing tape to the cluster of filings and tearing it off together with the contaminants. For easier operation, it is worth considering ordering a rod in a version with a cleaning sleeve.
The Gauss value tells us how effectively and deeply the magnet will catch contaminants. For basic machine protection against pieces of iron, standard power is sufficient. High induction is necessary when contaminants are microscopic or weakly magnetic.
We fulfill individual orders for bars perfectly matched to your machine or separator. We offer various tip options: threaded holes (e.g., M8, M10), protruding screws, flat pivots, mills, or handles. Contact us for a quote on a non-standard dimension.

Advantages and disadvantages of rare earth magnets.

Benefits

Besides their exceptional pulling force, neodymium magnets offer the following advantages:
  • They virtually do not lose strength, because even after ten years the performance loss is only ~1% (based on calculations),
  • Magnets very well protect themselves against demagnetization caused by external fields,
  • The use of an metallic finish of noble metals (nickel, gold, silver) causes the element to look better,
  • Neodymium magnets create maximum magnetic induction on a small area, which allows for strong attraction,
  • Neodymium magnets are characterized by extremely high magnetic induction on the magnet surface and are able to act (depending on the shape) even at a temperature of 230°C or more...
  • Thanks to modularity in constructing and the ability to adapt to specific needs,
  • Huge importance in future technologies – they are used in mass storage devices, electromotive mechanisms, precision medical tools, also modern systems.
  • Compactness – despite small sizes they generate large force, making them ideal for precision applications

Cons

What to avoid - cons of neodymium magnets: application proposals
  • To avoid cracks under impact, we suggest using special steel holders. Such a solution protects the magnet and simultaneously increases its durability.
  • NdFeB magnets lose strength when exposed to high temperatures. After reaching 80°C, many of them experience permanent weakening of strength (a factor is the shape and dimensions of the magnet). We offer magnets specially adapted to work at temperatures up to 230°C marked [AH], which are extremely resistant to heat
  • When exposed to humidity, magnets start to rust. To use them in conditions outside, it is recommended to use protective magnets, such as those in rubber or plastics, which secure oxidation as well as corrosion.
  • Limited possibility of producing threads in the magnet and complex shapes - preferred is a housing - magnetic holder.
  • Possible danger resulting from small fragments of magnets are risky, when accidentally swallowed, which becomes key in the aspect of protecting the youngest. Furthermore, small components of these magnets can complicate diagnosis medical in case of swallowing.
  • Due to expensive raw materials, their price is relatively high,

Pull force analysis

Highest magnetic holding forcewhat contributes to it?

Holding force of 0.00 kg is a result of laboratory testing conducted under specific, ideal conditions:
  • with the use of a yoke made of special test steel, ensuring full magnetic saturation
  • whose thickness reaches at least 10 mm
  • with an polished touching surface
  • without any air gap between the magnet and steel
  • under vertical force vector (90-degree angle)
  • at standard ambient temperature

Determinants of practical lifting force of a magnet

Please note that the magnet holding will differ depending on the following factors, starting with the most relevant:
  • Clearance – the presence of foreign body (rust, dirt, air) acts as an insulator, which lowers power rapidly (even by 50% at 0.5 mm).
  • Pull-off angle – remember that the magnet holds strongest perpendicularly. Under sliding down, the holding force drops significantly, often to levels of 20-30% of the maximum value.
  • Element thickness – for full efficiency, the steel must be adequately massive. Thin sheet restricts the lifting capacity (the magnet "punches through" it).
  • Material composition – different alloys attracts identically. Alloy additives worsen the interaction with the magnet.
  • Base smoothness – the more even the plate, the larger the contact zone and stronger the hold. Unevenness acts like micro-gaps.
  • Thermal factor – high temperature reduces pulling force. Exceeding the limit temperature can permanently demagnetize the magnet.

Lifting capacity testing was performed on a smooth plate of suitable thickness, under a perpendicular pulling force, however under attempts to slide the magnet the load capacity is reduced by as much as 75%. Moreover, even a small distance between the magnet’s surface and the plate decreases the holding force.

Precautions when working with NdFeB magnets
Compass and GPS

A powerful magnetic field negatively affects the functioning of compasses in smartphones and GPS navigation. Do not bring magnets near a smartphone to prevent damaging the sensors.

Keep away from computers

Do not bring magnets near a purse, computer, or TV. The magnetic field can permanently damage these devices and wipe information from cards.

Do not overheat magnets

Avoid heat. NdFeB magnets are sensitive to heat. If you need operation above 80°C, inquire about HT versions (H, SH, UH).

Conscious usage

Exercise caution. Rare earth magnets attract from a distance and connect with massive power, often quicker than you can move away.

Implant safety

Life threat: Strong magnets can deactivate heart devices and defibrillators. Stay away if you have electronic implants.

Mechanical processing

Powder created during machining of magnets is self-igniting. Do not drill into magnets unless you are an expert.

Pinching danger

Watch your fingers. Two powerful magnets will join immediately with a force of several hundred kilograms, destroying everything in their path. Exercise extreme caution!

Magnet fragility

Despite the nickel coating, neodymium is delicate and cannot withstand shocks. Avoid impacts, as the magnet may shatter into hazardous fragments.

Warning for allergy sufferers

Allergy Notice: The nickel-copper-nickel coating consists of nickel. If redness happens, immediately stop working with magnets and use protective gear.

This is not a toy

Adult use only. Tiny parts pose a choking risk, leading to intestinal necrosis. Keep away from kids and pets.

Danger! Want to know more? Read our article: Are neodymium magnets dangerous?