Product available Ships today (order by 14:00) CO2 GPSR PPWR REACH

SM 28x325 [2xM8] / N52 - magnetic separator

magnetic separator

Catalog no 130521

GTIN/EAN: 5906301815099

Diameter Ø
28 mm [±1 mm]
Height
325 mm [±1 mm]
Weight
1580.54 g
Magnetic Flux
~ 8 500 Gauss [±5%]

How we measure these parameters — certificates and measurements

920.00 zł net / pcs

1131.60 zł with VAT (23% VAT) / pcs

price for transport

bulk discounts:

Need more?

Quantity
Net
Gross
price from 1 pcs
920.00 zł
1131.60 zł
price from 5 pcs
828.00 zł
1018.44 zł

Frequently asked questions

How do I choose a separator for fine contamination and check availability?
Start with the size and type of contaminant, the material flow and the working surface. Compare the magnetic-field data and dimensions stated on the selected product card, and check current availability there.
Where can I order a separator for a production line, and what should I check?
Match the device to the installation dimensions, material flow, cleaning method and housing requirements. A drawing or the dimensions of the transfer point help determine whether a catalogue model fits or a custom version is needed.
How can I verify a separator's declared magnetic parameters before purchase?
Ask for the measured value, the point of measurement and the method or instrument used. A field-strength figure without its measurement conditions cannot be compared reliably with another product.
Can a magnetic beam withstand continuous work on a production line?
Check the construction, mounting and cleaning procedure for the chosen beam. Captured metal must be removed regularly; a layer of particles can reduce effective separation even when the magnets themselves are sound.
What roller design is suitable for a dusty environment?
Check the bearing protection, surface finish and cleaning access of the selected model. Dust accumulation and abrasion depend on the installation, so specify the actual process conditions before choosing a version.
How do I choose the size of a hand-held separator?
Match the rod diameter and length to the container and material depth, and consider the tool's weight for repeated manual work. Use the dimensions and magnetic data on the current product card.
What is a hand-held separator for, and how is it different from a built-in rod?
A built-in rod stays in the process line. A hand-held separator is moved through a material sample or container and then cleaned. It is useful for spot checks or occasional cleanup when permanent installation is not required.
Which separator type suits a small production plant?
Choose by the point in the process: a grate at a hopper, a beam over a conveyor, a built-in rod in a chute or pipe, or a hand-held tool for spot checks. A magnetic gripper handles steel parts rather than separating contamination.
Want to talk magnets?

Call us now +48 888 99 98 98 alternatively let us know using contact form the contact section.
Specifications and structure of a neodymium magnet can be estimated using our power calculator.

Order by 14:00 and we’ll ship today!

Product card - SM 28x325 [2xM8] / N52 - magnetic separator

Specification / characteristics - SM 28x325 [2xM8] / N52 - magnetic separator

properties
properties values
Cat. no. 130521
GTIN/EAN 5906301815099
Production/Distribution Dhit sp. z o.o.
ul. Zielona 14 05-850 Ożarów Mazowiecki PL
Country of origin Poland / China / Germany
Customs code 85059029
Diameter Ø 28 mm [±1 mm]
Height 325 mm [±1 mm]
Weight 1580.54 g
Material Type Stainless steel AISI 304 / A2
Magnetic Flux ~ 8 500 Gauss [±5%]
Size/Mount Quantity M8x2
Polarity circumferential - 12 poles
Casing Tube Thickness 1 mm
Manufacturing Tolerance ±1 mm

Magnetic properties of material N52

Specification / characteristics SM 28x325 [2xM8] / N52 - magnetic separator
properties values units
Remanence Br ? 14.2-14.7 kGs
Remanence Br ? 1420-1470 mT
Coercivity bHc ? 10.8-12.5 kOe
Coercivity bHc ? 860-995 kA/m
Intrinsic coercivity iHc ≥ 12 kOe
Intrinsic coercivity iHc ≥ 955 kA/m
Energy product BHmax ? 48-53 BH max MGOe
Energy product BHmax ? 380-422 BH max KJ/m
Maximum working temperature ? ≤ 60 °C

Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C

Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C
properties values units
Vickers hardness ≥550 Hv
Density ≥7.4 g/cm3
Curie Temperature TC 310 °C
Curie Temperature TF 590 °F
Specific resistance 150 μΩ⋅cm
Bending strength 250 MPa
Compressive strength 1000~1100 MPa
Thermal expansion parallel (∥) to orientation (M) (3-4) x 10-6 °C-1
Thermal expansion perpendicular (⊥) to orientation (M) -(1-3) x 10-6 °C-1
Young's modulus 1.7 x 104 kg/mm²

Table 1: Rod construction
SM 28x325 [2xM8] / N52

Parameter Value Description / Unit
Diameter (Ø) 28 mm
Total length 325 mm (L)
Active length 289 mm
Section count 12 modules
Dead zone 36 mm (2x 18mm starter)
Weight (est.) ~1521 g
Active area 254 cm² (Area)
Housing material AISI 304 1.4301 (Inox)
Surface finish Ra < 0.8 µm Polished
Temp. class 60°C N52
Force loss (at max °C) -8.6% Reversible loss (physics)
Force (calculated) 22.7 kg (theor.)
Induction (surface) ~8 500 Gauss (Max)

Chart 2: Field profile (12 sections)

Chart 3: Temperature performance

Technical and environmental data

Chemical composition

iron (Fe) 64% – 68%
neodymium (Nd) 29% – 32%
boron (B) 1.1% – 1.2%
dysprosium (Dy) 0.5% – 2.0%
coating (Ni-Cu-Ni) < 0.05%

Sustainability

recyclability (EoL) 100%
recycled raw materials ~10% (pre-cons)
carbon footprint low / zredukowany
waste code (EWC) 16 02 16
Safety card (GPSR)
responsible entity
Dhit sp. z o.o.
ul. Kościuszki 6A, 05-850 Ożarów Mazowiecki
tel: +48 22 499 98 98 | e-mail: bok@dhit.pl
batch number/type
id: 130521-2026
Magnet Unit Converter

Pulling force


Magnetic Induction

See more proposals

This product serves to effectively catch ferromagnetic contaminants from bulk and liquid products. It is commonly used for cleaning flour, sugar, plastic granules, as well as oils and coolants. Thanks to the use of strong neodymium magnets, the rod catches even metallic dust.
The construction relies on a sealed, welded stainless steel housing, polished smooth. The center is filled with NdFeB magnets and pole pieces, arranged to maximize the field on the tube surface. Thanks to this, the rod is durable, hygienic, and easy to keep clean.
Metal contaminants are strongly attracted, so removing them with a bare hand or glove can be difficult. You can use compressed air or special non-magnetic strippers (rings). In industry, cover tubes (so-called Easy Clean system) are used, from which the magnetic insert slides out.
Magnetic induction measured in Gauss (Gs) determines the density of magnetic flux on the rod surface. Standard rods (~8000 Gs) are sufficient for catching screws, nails, and steel shavings. High Power versions (~12000-14000 Gs) are necessary for catching metallic dust, oxides, and stainless steel after processing.
We can produce a rod of non-standard length with any mounting termination. We offer various tip options: threaded holes (e.g., M8, M10), protruding screws, flat pivots, mills, or handles. Contact us for a quote on a non-standard dimension.

Advantages and disadvantages of Nd2Fe14B magnets.

Benefits

Besides their exceptional field intensity, neodymium magnets offer the following advantages:
  • Their magnetic field remains stable, and after approximately ten years it decreases only by ~1% (according to research),
  • Neodymium magnets are exceptionally resistant to loss of magnetic properties caused by external interference,
  • A magnet with a shiny nickel surface looks better,
  • Magnetic induction on the top side of the magnet turns out to be maximum,
  • Due to their durability and thermal resistance, neodymium magnets are capable of operate (depending on the form) even at high temperatures reaching 230°C or more...
  • Thanks to versatility in forming and the ability to customize to unusual requirements,
  • Significant place in modern technologies – they serve a role in HDD drives, electric motors, diagnostic systems, also industrial machines.
  • Relatively small size with high pulling force – neodymium magnets offer impressive pulling force in tiny dimensions, which enables their usage in miniature devices

Limitations

Cons of neodymium magnets: application proposals
  • To avoid cracks upon strong impacts, we suggest using special steel housings. Such a solution secures the magnet and simultaneously increases its durability.
  • Do not exceed this material temperature limit: 60°C. Overheating may permanently weaken the magnet.
  • Magnets exposed to a humid environment can corrode. Therefore when using outdoors, we advise using water-impermeable magnets made of rubber, plastic or other material protecting against moisture
  • Due to limitations in realizing threads and complex shapes in magnets, we recommend using a housing - magnetic mechanism.
  • Health risk related to microscopic parts of magnets can be dangerous, in case of ingestion, which becomes key in the context of child safety. Additionally, tiny parts of these products are able to disrupt the diagnostic process medical after entering the body.
  • High unit price – neodymium magnets are more expensive than other types of magnets (e.g. ferrite), which hinders application in large quantities

Pull force analysis

Maximum magnetic pulling force – what it depends on?

The load parameter shown represents the maximum value, recorded under laboratory conditions, meaning:
  • with the contact of a yoke made of special test steel, ensuring full magnetic saturation
  • possessing a thickness of minimum 10 mm to avoid saturation
  • with a surface free of scratches
  • without any clearance between the magnet and steel
  • under vertical force direction (90-degree angle)
  • in neutral thermal conditions

Lifting capacity in practice – influencing factors

Effective lifting capacity is influenced by specific conditions, such as (from most important):
  • Distance (betwixt the magnet and the plate), since even a tiny clearance (e.g. 0.5 mm) can cause a drastic drop in force by up to 50% (this also applies to paint, corrosion or dirt).
  • Pull-off angle – remember that the magnet holds strongest perpendicularly. Under shear forces, the capacity drops drastically, often to levels of 20-30% of the maximum value.
  • Steel thickness – insufficiently thick sheet does not close the flux, causing part of the flux to be escaped to the other side.
  • Metal type – not every steel reacts the same. High carbon content worsen the attraction effect.
  • Surface quality – the smoother and more polished the plate, the better the adhesion and higher the lifting capacity. Unevenness creates an air distance.
  • Temperature influence – hot environment reduces pulling force. Exceeding the limit temperature can permanently damage the magnet.

Lifting capacity testing was carried out on plates with a smooth surface of optimal thickness, under a perpendicular pulling force, in contrast under attempts to slide the magnet the load capacity is reduced by as much as 75%. In addition, even a small distance between the magnet’s surface and the plate reduces the holding force.

Safe handling of neodymium magnets
Mechanical processing

Powder produced during cutting of magnets is combustible. Do not drill into magnets unless you are an expert.

Magnet fragility

NdFeB magnets are sintered ceramics, meaning they are prone to chipping. Clashing of two magnets leads to them cracking into small pieces.

Nickel coating and allergies

Certain individuals have a sensitization to nickel, which is the typical protective layer for NdFeB magnets. Frequent touching can result in a rash. It is best to use protective gloves.

Serious injuries

Watch your fingers. Two large magnets will join instantly with a force of massive weight, destroying everything in their path. Exercise extreme caution!

Do not underestimate power

Handle with care. Rare earth magnets attract from a distance and connect with huge force, often faster than you can move away.

Implant safety

Medical warning: Neodymium magnets can turn off pacemakers and defibrillators. Do not approach if you have medical devices.

Magnetic interference

A powerful magnetic field negatively affects the functioning of magnetometers in smartphones and navigation systems. Keep magnets near a smartphone to prevent damaging the sensors.

Data carriers

Avoid bringing magnets near a wallet, computer, or TV. The magnetic field can permanently damage these devices and erase data from cards.

No play value

Strictly keep magnets out of reach of children. Choking hazard is high, and the consequences of magnets clamping inside the body are very dangerous.

Power loss in heat

Regular neodymium magnets (grade N) lose power when the temperature surpasses 80°C. This process is irreversible.

Security! Want to know more? Read our article: Are neodymium magnets dangerous?