SM 32x225 [2xM8] / N42 - magnetic separator
magnetic separator
Catalog no 130375
GTIN/EAN: 5906301813231
- Diameter Ø
- 32 mm [±1 mm]
- Height
- 225 mm [±1 mm]
- Weight
- 1245 g
- Magnetic Flux
- ~ 8 000 Gauss [±5%]
How we measure these parameters — certificates and measurements
690.00 zł net / pcs
848.70 zł with VAT (23% VAT) / pcs
bulk discounts:
Need more?Frequently asked questions
Which rod should I choose for fine contamination?
Which rod pitch should I choose?
Why does efficiency drop after a few weeks of operation?
Call us now
+48 888 99 98 98
alternatively let us know using
contact form
the contact section.
Specifications and structure of a neodymium magnet can be estimated using our
power calculator.
Order by 14:00 and we’ll ship today!
Product card - SM 32x225 [2xM8] / N42 - magnetic separator
Specification / characteristics - SM 32x225 [2xM8] / N42 - magnetic separator
| properties | values |
|---|---|
| Cat. no. | 130375 |
| GTIN/EAN | 5906301813231 |
| Production/Distribution | Dhit sp. z o.o. |
| Country of origin | Poland / China / Germany |
| Customs code | 85059029 |
| Diameter Ø | 32 mm [±1 mm] |
| Height | 225 mm [±1 mm] |
| Weight | 1245 g |
| Material Type | Stainless steel AISI 304 / A2 |
| Magnetic Flux | ~ 8 000 Gauss [±5%] |
| Size/Mount Quantity | 2xM8 |
| Polarity | circumferential - 8 poles |
| Casing Tube Thickness | 1 mm |
| Manufacturing Tolerance | ±1 mm |
Magnetic properties of material N42
| properties | values | units |
|---|---|---|
| Remanence Br ? | 12.9-13.2 | kGs |
| Remanence Br ? | 1290-1320 | mT |
| Coercivity bHc ? | 10.8-12.0 | kOe |
| Coercivity bHc ? | 860-955 | kA/m |
| Intrinsic coercivity iHc | ≥ 12 | kOe |
| Intrinsic coercivity iHc | ≥ 955 | kA/m |
| Energy product BHmax ? | 40-42 | BH max MGOe |
| Energy product BHmax ? | 318-334 | BH max KJ/m |
| Maximum working temperature ? | ≤ 80 | °C |
Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C
| properties | values | units |
|---|---|---|
| Vickers hardness | ≥550 | Hv |
| Density | ≥7.4 | g/cm3 |
| Curie Temperature TC | 310 | °C |
| Curie Temperature TF | 590 | °F |
| Specific resistance | 150 | μΩ⋅cm |
| Bending strength | 250 | MPa |
| Compressive strength | 1000~1100 | MPa |
| Thermal expansion parallel (∥) to orientation (M) | (3-4) x 10-6 | °C-1 |
| Thermal expansion perpendicular (⊥) to orientation (M) | -(1-3) x 10-6 | °C-1 |
| Young's modulus | 1.7 x 104 | kg/mm² |
Table 1: Rod construction
SM 32x225 [2xM8] / N42
| Parameter | Value | Description / Unit |
|---|---|---|
| Diameter (Ø) | 32 | mm |
| Total length | 225 | mm (L) |
| Active length | 189 | mm |
| Section count | 8 | modules |
| Dead zone | 36 | mm (2x 18mm starter) |
| Weight (est.) | ~1375 | g |
| Active area | 190 | cm² (Area) |
| Housing material | AISI 304 | 1.4301 (Inox) |
| Surface finish | Ra < 0.8 µm | Polished |
| Temp. class | 80°C | Standard (N) |
| Force loss (at max °C) | -12.8% | Reversible loss (physics) |
| Force (calculated) | 26.2 | kg (theor.) |
| Induction (surface) | ~8 000 | Gauss (Max) |
Chart 2: Field profile (8 sections)
Chart 3: Temperature performance
Material specification
| iron (Fe) | 64% – 68% |
| neodymium (Nd) | 29% – 32% |
| boron (B) | 1.1% – 1.2% |
| dysprosium (Dy) | 0.5% – 2.0% |
| coating (Ni-Cu-Ni) | < 0.05% |
Environmental data
| recyclability (EoL) | 100% |
| recycled raw materials | ~10% (pre-cons) |
| carbon footprint | low / zredukowany |
| waste code (EWC) | 16 02 16 |
Other offers
Advantages as well as disadvantages of neodymium magnets.
Benefits
- They have constant strength, and over around 10 years their attraction force decreases symbolically – ~1% (in testing),
- Magnets perfectly defend themselves against demagnetization caused by external fields,
- In other words, due to the smooth layer of nickel, the element looks attractive,
- Neodymium magnets generate maximum magnetic induction on a small area, which allows for strong attraction,
- Through (appropriate) combination of ingredients, they can achieve high thermal resistance, allowing for functioning at temperatures reaching 230°C and above...
- Possibility of exact machining as well as adapting to defined applications,
- Key role in modern industrial fields – they are used in magnetic memories, brushless drives, medical equipment, and modern systems.
- Compactness – despite small sizes they provide effective action, making them ideal for precision applications
Weaknesses
- They are prone to damage upon too strong impacts. To avoid cracks, it is worth securing magnets using a steel holder. Such protection not only shields the magnet but also improves its resistance to damage
- Neodymium magnets demagnetize when exposed to high temperatures. After reaching 80°C, many of them experience permanent drop of power (a factor is the shape as well as dimensions of the magnet). We offer magnets specially adapted to work at temperatures up to 230°C marked [AH], which are very resistant to heat
- When exposed to humidity, magnets usually rust. For applications outside, it is recommended to use protective magnets, such as those in rubber or plastics, which prevent oxidation and corrosion.
- Limited possibility of making nuts in the magnet and complex forms - preferred is a housing - magnetic holder.
- Health risk resulting from small fragments of magnets are risky, in case of ingestion, which is particularly important in the aspect of protecting the youngest. Additionally, small components of these products are able to complicate diagnosis medical in case of swallowing.
- Higher cost of purchase is a significant factor to consider compared to ceramic magnets, especially in budget applications
Pull force analysis
Highest magnetic holding force – what affects it?
- with the use of a yoke made of special test steel, ensuring maximum field concentration
- whose thickness is min. 10 mm
- characterized by lack of roughness
- with zero gap (without impurities)
- during pulling in a direction vertical to the plane
- in temp. approx. 20°C
Lifting capacity in real conditions – factors
- Gap (betwixt the magnet and the plate), since even a tiny distance (e.g. 0.5 mm) can cause a decrease in force by up to 50% (this also applies to paint, rust or dirt).
- Angle of force application – maximum parameter is reached only during pulling at a 90° angle. The shear force of the magnet along the plate is standardly many times smaller (approx. 1/5 of the lifting capacity).
- Substrate thickness – for full efficiency, the steel must be sufficiently thick. Paper-thin metal restricts the lifting capacity (the magnet "punches through" it).
- Material composition – different alloys reacts the same. Alloy additives worsen the interaction with the magnet.
- Base smoothness – the more even the plate, the better the adhesion and stronger the hold. Roughness acts like micro-gaps.
- Temperature influence – high temperature reduces pulling force. Exceeding the limit temperature can permanently demagnetize the magnet.
Lifting capacity testing was performed on a smooth plate of optimal thickness, under perpendicular forces, however under attempts to slide the magnet the load capacity is reduced by as much as fivefold. Additionally, even a minimal clearance between the magnet and the plate reduces the holding force.
Safe handling of NdFeB magnets
Do not drill into magnets
Powder generated during machining of magnets is self-igniting. Avoid drilling into magnets unless you are an expert.
Protective goggles
Despite metallic appearance, the material is delicate and cannot withstand shocks. Avoid impacts, as the magnet may shatter into sharp, dangerous pieces.
Choking Hazard
Always keep magnets away from children. Risk of swallowing is significant, and the consequences of magnets clamping inside the body are tragic.
GPS and phone interference
A powerful magnetic field negatively affects the operation of magnetometers in phones and GPS navigation. Maintain magnets near a smartphone to prevent damaging the sensors.
Cards and drives
Data protection: Neodymium magnets can ruin payment cards and sensitive devices (pacemakers, medical aids, timepieces).
Immense force
Exercise caution. Rare earth magnets attract from a distance and snap with huge force, often quicker than you can move away.
ICD Warning
Life threat: Neodymium magnets can turn off heart devices and defibrillators. Stay away if you have medical devices.
Heat warning
Watch the temperature. Heating the magnet above 80 degrees Celsius will permanently weaken its magnetic structure and strength.
Crushing force
Pinching hazard: The attraction force is so immense that it can cause blood blisters, pinching, and even bone fractures. Protective gloves are recommended.
Sensitization to coating
A percentage of the population suffer from a sensitization to Ni, which is the typical protective layer for NdFeB magnets. Extended handling may cause a rash. We strongly advise use protective gloves.