Product available Ships today (order by 14:00) CO2 GPSR PPWR REACH

SM 32x225 [2xM8] / N42 - magnetic separator

magnetic separator

Catalog no 130375

GTIN/EAN: 5906301813231

Diameter Ø
32 mm [±1 mm]
Height
225 mm [±1 mm]
Weight
1245 g
Magnetic Flux
~ 8 000 Gauss [±5%]

How we measure these parameters — certificates and measurements

690.00net / pcs

848.70 zł with VAT (23% VAT) / pcs

price for transport

bulk discounts:

Need more?

Quantity
Net
Gross
price from 1 pcs
690.00 zł
848.70 zł
price from 5 pcs
655.50 zł
806.27 zł
price from 10 pcs
621.00 zł
763.83 zł

Frequently asked questions

Which rod should I choose for fine contamination?
For particles below 0.5 mm — a Ø32 mm rod in grade N52, with surface induction of about 10,000 Gs. A Ø25 rod in grade N42 gives about 6,500 Gs and is chosen for contamination above 1 mm: bolts, washers, pieces of wire.
Which rod pitch should I choose?
The narrow pitch, 40 mm centre to centre, for fine free-flowing fractions — it gives denser coverage of the cross-section. The wide pitch, 50 mm, for granulates and for damp, greasy or sticky materials, where a narrow pitch risks the material bridging above the rods.
Why does efficiency drop after a few weeks of operation?
Almost always because the separator has not been cleaned. The layer of captured particles shields the field, and further particles settle on that layer rather than on the rod surface, where the gradient is far stronger. The magnets themselves do not weaken at that rate.
Want to talk magnets?

Call us now +48 888 99 98 98 alternatively let us know using contact form the contact section.
Specifications and structure of a neodymium magnet can be estimated using our power calculator.

Order by 14:00 and we’ll ship today!

Product card - SM 32x225 [2xM8] / N42 - magnetic separator

Specification / characteristics - SM 32x225 [2xM8] / N42 - magnetic separator

properties
properties values
Cat. no. 130375
GTIN/EAN 5906301813231
Production/Distribution Dhit sp. z o.o.
ul. Zielona 14 05-850 Ożarów Mazowiecki PL
Country of origin Poland / China / Germany
Customs code 85059029
Diameter Ø 32 mm [±1 mm]
Height 225 mm [±1 mm]
Weight 1245 g
Material Type Stainless steel AISI 304 / A2
Magnetic Flux ~ 8 000 Gauss [±5%]
Size/Mount Quantity 2xM8
Polarity circumferential - 8 poles
Casing Tube Thickness 1 mm
Manufacturing Tolerance ±1 mm

Magnetic properties of material N42

Specification / characteristics SM 32x225 [2xM8] / N42 - magnetic separator
properties values units
Remanence Br ? 12.9-13.2 kGs
Remanence Br ? 1290-1320 mT
Coercivity bHc ? 10.8-12.0 kOe
Coercivity bHc ? 860-955 kA/m
Intrinsic coercivity iHc ≥ 12 kOe
Intrinsic coercivity iHc ≥ 955 kA/m
Energy product BHmax ? 40-42 BH max MGOe
Energy product BHmax ? 318-334 BH max KJ/m
Maximum working temperature ? ≤ 80 °C

Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C

Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C
properties values units
Vickers hardness ≥550 Hv
Density ≥7.4 g/cm3
Curie Temperature TC 310 °C
Curie Temperature TF 590 °F
Specific resistance 150 μΩ⋅cm
Bending strength 250 MPa
Compressive strength 1000~1100 MPa
Thermal expansion parallel (∥) to orientation (M) (3-4) x 10-6 °C-1
Thermal expansion perpendicular (⊥) to orientation (M) -(1-3) x 10-6 °C-1
Young's modulus 1.7 x 104 kg/mm²

Table 1: Rod construction
SM 32x225 [2xM8] / N42

Parameter Value Description / Unit
Diameter (Ø) 32 mm
Total length 225 mm (L)
Active length 189 mm
Section count 8 modules
Dead zone 36 mm (2x 18mm starter)
Weight (est.) ~1375 g
Active area 190 cm² (Area)
Housing material AISI 304 1.4301 (Inox)
Surface finish Ra < 0.8 µm Polished
Temp. class 80°C Standard (N)
Force loss (at max °C) -12.8% Reversible loss (physics)
Force (calculated) 26.2 kg (theor.)
Induction (surface) ~8 000 Gauss (Max)

Chart 2: Field profile (8 sections)

Chart 3: Temperature performance

Technical specification and ecology

Material specification

iron (Fe) 64% – 68%
neodymium (Nd) 29% – 32%
boron (B) 1.1% – 1.2%
dysprosium (Dy) 0.5% – 2.0%
coating (Ni-Cu-Ni) < 0.05%

Environmental data

recyclability (EoL) 100%
recycled raw materials ~10% (pre-cons)
carbon footprint low / zredukowany
waste code (EWC) 16 02 16
Safety card (GPSR)
responsible entity
Dhit sp. z o.o.
ul. Kościuszki 6A, 05-850 Ożarów Mazowiecki
tel: +48 22 499 98 98 | e-mail: bok@dhit.pl
batch number/type
id: 130375-2026
Quick Unit Converter

Magnet pull force


Field Strength

Other offers

This product serves to effectively catch ferromagnetic contaminants from bulk and liquid products. It is mounted in chutes, hoppers, and pipelines to protect production machines from failure. Thanks to the use of strong neodymium magnets, the rod catches even metallic dust.
The rod consists of a cover tube made of high-quality acid-resistant steel (AISI 304 or 316). Inside there is a stack of strong neodymium magnets arranged in a special configuration (magnetic circuit). Such construction ensures full resistance to corrosion, water, oils, and acids.
Metal contaminants are strongly attracted, so removing them with a bare hand or glove can be difficult. We recommend sticking packing tape to the cluster of filings and tearing it off together with the contaminants. For easier operation, it is worth considering ordering a rod in a version with a cleaning sleeve.
The more Gauss, the smaller and more weakly magnetic particles will be effectively caught. The economical version (8kGs) handles large pieces of metal perfectly. For the food and precision industry, we recommend the highest induction parameters.
Yes, as a manufacturer, we make rods of any length and diameter (standard is dia 25mm and 32mm). We offer various tip options: threaded holes (e.g., M8, M10), protruding screws, flat pivots, mills, or handles. We ensure fast realization of special orders and technical advice.

Advantages as well as disadvantages of neodymium magnets.

Benefits

In addition to their magnetic capacity, neodymium magnets provide the following advantages:
  • They have constant strength, and over around 10 years their attraction force decreases symbolically – ~1% (in testing),
  • Magnets perfectly defend themselves against demagnetization caused by external fields,
  • In other words, due to the smooth layer of nickel, the element looks attractive,
  • Neodymium magnets generate maximum magnetic induction on a small area, which allows for strong attraction,
  • Through (appropriate) combination of ingredients, they can achieve high thermal resistance, allowing for functioning at temperatures reaching 230°C and above...
  • Possibility of exact machining as well as adapting to defined applications,
  • Key role in modern industrial fields – they are used in magnetic memories, brushless drives, medical equipment, and modern systems.
  • Compactness – despite small sizes they provide effective action, making them ideal for precision applications

Weaknesses

Drawbacks and weaknesses of neodymium magnets: application proposals
  • They are prone to damage upon too strong impacts. To avoid cracks, it is worth securing magnets using a steel holder. Such protection not only shields the magnet but also improves its resistance to damage
  • Neodymium magnets demagnetize when exposed to high temperatures. After reaching 80°C, many of them experience permanent drop of power (a factor is the shape as well as dimensions of the magnet). We offer magnets specially adapted to work at temperatures up to 230°C marked [AH], which are very resistant to heat
  • When exposed to humidity, magnets usually rust. For applications outside, it is recommended to use protective magnets, such as those in rubber or plastics, which prevent oxidation and corrosion.
  • Limited possibility of making nuts in the magnet and complex forms - preferred is a housing - magnetic holder.
  • Health risk resulting from small fragments of magnets are risky, in case of ingestion, which is particularly important in the aspect of protecting the youngest. Additionally, small components of these products are able to complicate diagnosis medical in case of swallowing.
  • Higher cost of purchase is a significant factor to consider compared to ceramic magnets, especially in budget applications

Pull force analysis

Highest magnetic holding forcewhat affects it?

Information about lifting capacity was determined for the most favorable conditions, including:
  • with the use of a yoke made of special test steel, ensuring maximum field concentration
  • whose thickness is min. 10 mm
  • characterized by lack of roughness
  • with zero gap (without impurities)
  • during pulling in a direction vertical to the plane
  • in temp. approx. 20°C

Lifting capacity in real conditions – factors

In practice, the actual holding force results from several key aspects, listed from most significant:
  • Gap (betwixt the magnet and the plate), since even a tiny distance (e.g. 0.5 mm) can cause a decrease in force by up to 50% (this also applies to paint, rust or dirt).
  • Angle of force application – maximum parameter is reached only during pulling at a 90° angle. The shear force of the magnet along the plate is standardly many times smaller (approx. 1/5 of the lifting capacity).
  • Substrate thickness – for full efficiency, the steel must be sufficiently thick. Paper-thin metal restricts the lifting capacity (the magnet "punches through" it).
  • Material composition – different alloys reacts the same. Alloy additives worsen the interaction with the magnet.
  • Base smoothness – the more even the plate, the better the adhesion and stronger the hold. Roughness acts like micro-gaps.
  • Temperature influence – high temperature reduces pulling force. Exceeding the limit temperature can permanently demagnetize the magnet.

Lifting capacity testing was performed on a smooth plate of optimal thickness, under perpendicular forces, however under attempts to slide the magnet the load capacity is reduced by as much as fivefold. Additionally, even a minimal clearance between the magnet and the plate reduces the holding force.

Safe handling of NdFeB magnets
Do not drill into magnets

Powder generated during machining of magnets is self-igniting. Avoid drilling into magnets unless you are an expert.

Protective goggles

Despite metallic appearance, the material is delicate and cannot withstand shocks. Avoid impacts, as the magnet may shatter into sharp, dangerous pieces.

Choking Hazard

Always keep magnets away from children. Risk of swallowing is significant, and the consequences of magnets clamping inside the body are tragic.

GPS and phone interference

A powerful magnetic field negatively affects the operation of magnetometers in phones and GPS navigation. Maintain magnets near a smartphone to prevent damaging the sensors.

Cards and drives

Data protection: Neodymium magnets can ruin payment cards and sensitive devices (pacemakers, medical aids, timepieces).

Immense force

Exercise caution. Rare earth magnets attract from a distance and snap with huge force, often quicker than you can move away.

ICD Warning

Life threat: Neodymium magnets can turn off heart devices and defibrillators. Stay away if you have medical devices.

Heat warning

Watch the temperature. Heating the magnet above 80 degrees Celsius will permanently weaken its magnetic structure and strength.

Crushing force

Pinching hazard: The attraction force is so immense that it can cause blood blisters, pinching, and even bone fractures. Protective gloves are recommended.

Sensitization to coating

A percentage of the population suffer from a sensitization to Ni, which is the typical protective layer for NdFeB magnets. Extended handling may cause a rash. We strongly advise use protective gloves.

Security! Looking for details? Read our article: Why are neodymium magnets dangerous?