SM 28x250 [2xM8] / N52 - magnetic separator
magnetic separator
Catalog no 130522
- Diameter Ø
- 28 mm [±1 mm]
- Height
- 250 mm [±1 mm]
- Weight
- 1204.22 g
- Magnetic Flux
- ~ 8 500 Gauss [±5%]
How we measure these parameters — certificates and measurements
650.00 zł net / pcs
799.50 zł with VAT (23% VAT) / pcs
bulk discounts:
Need more?Frequently asked questions
Which rod should I choose for fine contamination?
Which rod pitch should I choose?
Why does efficiency drop after a few weeks of operation?
Call us now
+48 888 99 98 98
alternatively let us know using
contact form
the contact section.
Specifications and structure of a neodymium magnet can be estimated using our
power calculator.
Order by 14:00 and we’ll ship today!
Technical of the product - SM 28x250 [2xM8] / N52 - magnetic separator
Specification / characteristics - SM 28x250 [2xM8] / N52 - magnetic separator
| properties | values |
|---|---|
| Cat. no. | 130522 |
| Production/Distribution | Dhit sp. z o.o. |
| Country of origin | Poland / China / Germany |
| Customs code | 85059029 |
| Diameter Ø | 28 mm [±1 mm] |
| Height | 250 mm [±1 mm] |
| Weight | 1204.22 g |
| Material Type | Stainless steel AISI 304 / A2 |
| Magnetic Flux | ~ 8 500 Gauss [±5%] |
| Size/Mount Quantity | M8x2 |
| Polarity | circumferential - 9 poles |
| Casing Tube Thickness | 1 mm |
| Manufacturing Tolerance | ±1 mm |
Magnetic properties of material N52
| properties | values | units |
|---|---|---|
| Remanence Br ? | 14.2-14.7 | kGs |
| Remanence Br ? | 1420-1470 | mT |
| Coercivity bHc ? | 10.8-12.5 | kOe |
| Coercivity bHc ? | 860-995 | kA/m |
| Intrinsic coercivity iHc | ≥ 12 | kOe |
| Intrinsic coercivity iHc | ≥ 955 | kA/m |
| Energy product BHmax ? | 48-53 | BH max MGOe |
| Energy product BHmax ? | 380-422 | BH max KJ/m |
| Maximum working temperature ? | ≤ 80 | °C |
Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C
| properties | values | units |
|---|---|---|
| Vickers hardness | ≥550 | Hv |
| Density | ≥7.4 | g/cm3 |
| Curie Temperature TC | 310 | °C |
| Curie Temperature TF | 590 | °F |
| Specific resistance | 150 | μΩ⋅cm |
| Bending strength | 250 | MPa |
| Compressive strength | 1000~1100 | MPa |
| Thermal expansion parallel (∥) to orientation (M) | (3-4) x 10-6 | °C-1 |
| Thermal expansion perpendicular (⊥) to orientation (M) | -(1-3) x 10-6 | °C-1 |
| Young's modulus | 1.7 x 104 | kg/mm² |
Table 1: Rod construction
SM 28x250 [2xM8] / N52
| Parameter | Value | Description / Unit |
|---|---|---|
| Diameter (Ø) | 28 | mm |
| Total length | 250 | mm (L) |
| Active length | 214 | mm |
| Section count | 9 | modules |
| Dead zone | 36 | mm (2x 18mm starter) |
| Weight (est.) | ~1170 | g |
| Active area | 188 | cm² (Area) |
| Housing material | AISI 304 | 1.4301 (Inox) |
| Surface finish | Ra < 0.8 µm | Polished |
| Temp. class | 80°C | Standard (N) |
| Force loss (at max °C) | -12.8% | Reversible loss (physics) |
| Force (calculated) | 22.7 | kg (theor.) |
| Induction (surface) | ~8 500 | Gauss (Max) |
Chart 2: Field profile (9 sections)
Chart 3: Temperature performance
Material specification
| iron (Fe) | 64% – 68% |
| neodymium (Nd) | 29% – 32% |
| boron (B) | 1.1% – 1.2% |
| dysprosium (Dy) | 0.5% – 2.0% |
| coating (Ni-Cu-Ni) | < 0.05% |
Sustainability
| recyclability (EoL) | 100% |
| recycled raw materials | ~10% (pre-cons) |
| carbon footprint | low / zredukowany |
| waste code (EWC) | 16 02 16 |
See more products
Pros as well as cons of Nd2Fe14B magnets.
Advantages
- They retain attractive force for around 10 years – the drop is just ~1% (in theory),
- Magnets very well protect themselves against demagnetization caused by foreign field sources,
- By covering with a reflective layer of gold, the element gains an elegant look,
- They feature high magnetic induction at the operating surface, making them more effective,
- Due to their durability and thermal resistance, neodymium magnets can operate (depending on the form) even at high temperatures reaching 230°C or more...
- Considering the potential of flexible shaping and customization to custom projects, neodymium magnets can be modeled in a wide range of forms and dimensions, which expands the range of possible applications,
- Key role in innovative solutions – they serve a role in computer drives, motor assemblies, advanced medical instruments, and modern systems.
- Thanks to efficiency per cm³, small magnets offer high operating force, occupying minimum space,
Disadvantages
- Brittleness is one of their disadvantages. Upon intense impact they can fracture. We advise keeping them in a steel housing, which not only protects them against impacts but also increases their durability
- Neodymium magnets lose their strength under the influence of heating. As soon as 80°C is exceeded, many of them start losing their power. Therefore, we recommend our special magnets marked [AH], which maintain stability even at temperatures up to 230°C
- Magnets exposed to a humid environment can corrode. Therefore during using outdoors, we recommend using waterproof magnets made of rubber, plastic or other material resistant to moisture
- Due to limitations in producing nuts and complex forms in magnets, we propose using cover - magnetic mount.
- Health risk resulting from small fragments of magnets are risky, if swallowed, which is particularly important in the aspect of protecting the youngest. Furthermore, small components of these devices can be problematic in diagnostics medical when they are in the body.
- Higher cost of purchase is one of the disadvantages compared to ceramic magnets, especially in budget applications
Pull force analysis
Magnetic strength at its maximum – what contributes to it?
- on a base made of mild steel, effectively closing the magnetic field
- with a cross-section minimum 10 mm
- characterized by even structure
- under conditions of no distance (metal-to-metal)
- under axial force direction (90-degree angle)
- in temp. approx. 20°C
Key elements affecting lifting force
- Gap between surfaces – every millimeter of distance (caused e.g. by varnish or unevenness) diminishes the magnet efficiency, often by half at just 0.5 mm.
- Direction of force – highest force is obtained only during pulling at a 90° angle. The shear force of the magnet along the surface is usually several times lower (approx. 1/5 of the lifting capacity).
- Element thickness – to utilize 100% power, the steel must be adequately massive. Paper-thin metal limits the lifting capacity (the magnet "punches through" it).
- Material type – the best choice is pure iron steel. Cast iron may generate lower lifting capacity.
- Smoothness – full contact is possible only on smooth steel. Rough texture create air cushions, reducing force.
- Temperature – heating the magnet causes a temporary drop of force. Check the maximum operating temperature for a given model.
Lifting capacity testing was conducted on a smooth plate of suitable thickness, under a perpendicular pulling force, in contrast under shearing force the lifting capacity is smaller. Moreover, even a small distance between the magnet’s surface and the plate reduces the lifting capacity.
Safety rules for work with NdFeB magnets
Pacemakers
Health Alert: Strong magnets can deactivate pacemakers and defibrillators. Stay away if you have electronic implants.
Fire risk
Fire hazard: Rare earth powder is explosive. Avoid machining magnets in home conditions as this may cause fire.
Protective goggles
Watch out for shards. Magnets can explode upon violent connection, launching sharp fragments into the air. Eye protection is mandatory.
Compass and GPS
Note: rare earth magnets generate a field that confuses sensitive sensors. Keep a separation from your phone, device, and GPS.
Immense force
Before starting, read the rules. Sudden snapping can break the magnet or injure your hand. Be predictive.
Serious injuries
Large magnets can smash fingers in a fraction of a second. Never place your hand between two strong magnets.
Danger to the youngest
Always store magnets away from children. Ingestion danger is significant, and the consequences of magnets connecting inside the body are fatal.
Electronic hazard
Data protection: Strong magnets can ruin data carriers and delicate electronics (heart implants, hearing aids, timepieces).
Allergic reactions
Medical facts indicate that the nickel plating (standard magnet coating) is a potent allergen. If you have an allergy, avoid touching magnets with bare hands and opt for encased magnets.
Heat sensitivity
Standard neodymium magnets (grade N) undergo demagnetization when the temperature surpasses 80°C. Damage is permanent.