Product available Ships today (order by 14:00) CO2 GPSR PPWR REACH

SM 28x250 [2xM8] / N52 - magnetic separator

magnetic separator

Catalog no 130522

GTIN/EAN: 5906301815068

Diameter Ø
28 mm [±1 mm]
Height
250 mm [±1 mm]
Weight
1204.22 g
Magnetic Flux
~ 8 500 Gauss [±5%]

How we measure these parameters — certificates and measurements

650.00 zł net / pcs

799.50 zł with VAT (23% VAT) / pcs

price for transport

bulk discounts:

Need more?

Quantity
Net
Gross
price from 1 pcs
650.00 zł
799.50 zł
price from 5 pcs
617.50 zł
759.53 zł
price from 10 pcs
585.00 zł
719.55 zł

Frequently asked questions

How do I choose a separator for fine contamination and check availability?
Start with the size and type of contaminant, the material flow and the working surface. Compare the magnetic-field data and dimensions stated on the selected product card, and check current availability there.
Where can I order a separator for a production line, and what should I check?
Match the device to the installation dimensions, material flow, cleaning method and housing requirements. A drawing or the dimensions of the transfer point help determine whether a catalogue model fits or a custom version is needed.
How can I verify a separator's declared magnetic parameters before purchase?
Ask for the measured value, the point of measurement and the method or instrument used. A field-strength figure without its measurement conditions cannot be compared reliably with another product.
Can a magnetic beam withstand continuous work on a production line?
Check the construction, mounting and cleaning procedure for the chosen beam. Captured metal must be removed regularly; a layer of particles can reduce effective separation even when the magnets themselves are sound.
What roller design is suitable for a dusty environment?
Check the bearing protection, surface finish and cleaning access of the selected model. Dust accumulation and abrasion depend on the installation, so specify the actual process conditions before choosing a version.
How do I choose the size of a hand-held separator?
Match the rod diameter and length to the container and material depth, and consider the tool's weight for repeated manual work. Use the dimensions and magnetic data on the current product card.
What is a hand-held separator for, and how is it different from a built-in rod?
A built-in rod stays in the process line. A hand-held separator is moved through a material sample or container and then cleaned. It is useful for spot checks or occasional cleanup when permanent installation is not required.
Which separator type suits a small production plant?
Choose by the point in the process: a grate at a hopper, a beam over a conveyor, a built-in rod in a chute or pipe, or a hand-held tool for spot checks. A magnetic gripper handles steel parts rather than separating contamination.
Want to talk magnets?

Call us now +48 888 99 98 98 alternatively let us know using contact form the contact section.
Specifications and structure of a neodymium magnet can be estimated using our power calculator.

Order by 14:00 and we’ll ship today!

Technical of the product - SM 28x250 [2xM8] / N52 - magnetic separator

Specification / characteristics - SM 28x250 [2xM8] / N52 - magnetic separator

properties
properties values
Cat. no. 130522
GTIN/EAN 5906301815068
Production/Distribution Dhit sp. z o.o.
ul. Zielona 14 05-850 Ożarów Mazowiecki PL
Country of origin Poland / China / Germany
Customs code 85059029
Diameter Ø 28 mm [±1 mm]
Height 250 mm [±1 mm]
Weight 1204.22 g
Material Type Stainless steel AISI 304 / A2
Magnetic Flux ~ 8 500 Gauss [±5%]
Size/Mount Quantity M8x2
Polarity circumferential - 9 poles
Casing Tube Thickness 1 mm
Manufacturing Tolerance ±1 mm

Magnetic properties of material N52

Specification / characteristics SM 28x250 [2xM8] / N52 - magnetic separator
properties values units
Remanence Br ? 14.2-14.7 kGs
Remanence Br ? 1420-1470 mT
Coercivity bHc ? 10.8-12.5 kOe
Coercivity bHc ? 860-995 kA/m
Intrinsic coercivity iHc ≥ 12 kOe
Intrinsic coercivity iHc ≥ 955 kA/m
Energy product BHmax ? 48-53 BH max MGOe
Energy product BHmax ? 380-422 BH max KJ/m
Maximum working temperature ? ≤ 60 °C

Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C

Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C
properties values units
Vickers hardness ≥550 Hv
Density ≥7.4 g/cm3
Curie Temperature TC 310 °C
Curie Temperature TF 590 °F
Specific resistance 150 μΩ⋅cm
Bending strength 250 MPa
Compressive strength 1000~1100 MPa
Thermal expansion parallel (∥) to orientation (M) (3-4) x 10-6 °C-1
Thermal expansion perpendicular (⊥) to orientation (M) -(1-3) x 10-6 °C-1
Young's modulus 1.7 x 104 kg/mm²

Table 1: Rod construction
SM 28x250 [2xM8] / N52

Parameter Value Description / Unit
Diameter (Ø) 28 mm
Total length 250 mm (L)
Active length 214 mm
Section count 9 modules
Dead zone 36 mm (2x 18mm starter)
Weight (est.) ~1170 g
Active area 188 cm² (Area)
Housing material AISI 304 1.4301 (Inox)
Surface finish Ra < 0.8 µm Polished
Temp. class 60°C N52
Force loss (at max °C) -8.6% Reversible loss (physics)
Force (calculated) 22.7 kg (theor.)
Induction (surface) ~8 500 Gauss (Max)

Chart 2: Field profile (9 sections)

Chart 3: Temperature performance

Technical and environmental data

Material specification

iron (Fe) 64% – 68%
neodymium (Nd) 29% – 32%
boron (B) 1.1% – 1.2%
dysprosium (Dy) 0.5% – 2.0%
coating (Ni-Cu-Ni) < 0.05%

Sustainability

recyclability (EoL) 100%
recycled raw materials ~10% (pre-cons)
carbon footprint low / zredukowany
waste code (EWC) 16 02 16
Safety card (GPSR)
responsible entity
Dhit sp. z o.o.
ul. Kościuszki 6A, 05-850 Ożarów Mazowiecki
tel: +48 22 499 98 98 | e-mail: bok@dhit.pl
batch number/type
id: 130522-2026
Magnet Unit Converter

Pulling force


Magnetic Induction

See more products

A magnetic rod is the basic element of building grate separators and magnetic filters. It is commonly used for cleaning flour, sugar, plastic granules, as well as oils and coolants. Thanks to the use of strong neodymium magnets, the rod catches even metallic dust.
The outer layer is hygienic acid-resistant steel, approved for food contact. The center is filled with NdFeB magnets and pole pieces, arranged to maximize the field on the tube surface. Such construction ensures full resistance to corrosion, water, oils, and acids.
Metal filings stick to the surface very strongly, so cleaning requires strength or cleverness. You can use compressed air or special non-magnetic strippers (rings). For easier operation, it is worth considering ordering a rod in a version with a cleaning sleeve.
The Gauss value tells us how effectively and deeply the magnet will catch contaminants. Standard rods (~8000 Gs) are sufficient for catching screws, nails, and steel shavings. For the food and precision industry, we recommend the highest induction parameters.
We fulfill individual orders for bars perfectly matched to your machine or separator. The rod end is strictly adapted to the fastening system in your device. We ensure fast realization of special orders and technical advice.

Pros as well as cons of Nd2Fe14B magnets.

Advantages

In addition to their magnetic efficiency, neodymium magnets provide the following advantages:
  • They retain attractive force for around 10 years – the drop is just ~1% (in theory),
  • Magnets very well protect themselves against demagnetization caused by foreign field sources,
  • By covering with a reflective layer of gold, the element gains an elegant look,
  • They feature high magnetic induction at the operating surface, making them more effective,
  • Due to their durability and thermal resistance, neodymium magnets can operate (depending on the form) even at high temperatures reaching 230°C or more...
  • Considering the potential of flexible shaping and customization to custom projects, neodymium magnets can be modeled in a wide range of forms and dimensions, which expands the range of possible applications,
  • Key role in innovative solutions – they serve a role in computer drives, motor assemblies, advanced medical instruments, and modern systems.
  • Thanks to efficiency per cm³, small magnets offer high operating force, occupying minimum space,

Disadvantages

Characteristics of disadvantages of neodymium magnets: tips and applications.
  • Brittleness is one of their disadvantages. Upon intense impact they can fracture. We advise keeping them in a steel housing, which not only protects them against impacts but also increases their durability
  • Do not exceed this material temperature limit: 60°C. Overheating may permanently weaken the magnet.
  • Magnets exposed to a humid environment can corrode. Therefore during using outdoors, we recommend using waterproof magnets made of rubber, plastic or other material resistant to moisture
  • Due to limitations in producing nuts and complex forms in magnets, we propose using cover - magnetic mount.
  • Health risk resulting from small fragments of magnets are risky, if swallowed, which is particularly important in the aspect of protecting the youngest. Furthermore, small components of these devices can be problematic in diagnostics medical when they are in the body.
  • Higher cost of purchase is one of the disadvantages compared to ceramic magnets, especially in budget applications

Pull force analysis

Magnetic strength at its maximum – what contributes to it?

Information about lifting capacity was determined for optimal configuration, including:
  • on a base made of mild steel, effectively closing the magnetic field
  • with a cross-section minimum 10 mm
  • characterized by even structure
  • under conditions of no distance (metal-to-metal)
  • under axial force direction (90-degree angle)
  • in temp. approx. 20°C

Key elements affecting lifting force

Please note that the application force will differ depending on elements below, starting with the most relevant:
  • Gap between surfaces – every millimeter of distance (caused e.g. by varnish or unevenness) diminishes the magnet efficiency, often by half at just 0.5 mm.
  • Direction of force – highest force is obtained only during pulling at a 90° angle. The shear force of the magnet along the surface is usually several times lower (approx. 1/5 of the lifting capacity).
  • Element thickness – to utilize 100% power, the steel must be adequately massive. Paper-thin metal limits the lifting capacity (the magnet "punches through" it).
  • Material type – the best choice is pure iron steel. Cast iron may generate lower lifting capacity.
  • Smoothness – full contact is possible only on smooth steel. Rough texture create air cushions, reducing force.
  • Temperature – heating the magnet causes a temporary drop of force. Check the maximum operating temperature for a given model.

Lifting capacity testing was conducted on a smooth plate of suitable thickness, under a perpendicular pulling force, in contrast under shearing force the lifting capacity is smaller. Moreover, even a small distance between the magnet’s surface and the plate reduces the lifting capacity.

Safety rules for work with NdFeB magnets
Serious injuries

Large magnets can smash fingers in a fraction of a second. Never place your hand between two strong magnets.

Immense force

Before starting, read the rules. Sudden snapping can break the magnet or injure your hand. Be predictive.

Electronic hazard

Data protection: Strong magnets can ruin data carriers and delicate electronics (heart implants, hearing aids, timepieces).

Allergic reactions

Medical facts indicate that the nickel plating (standard magnet coating) is a potent allergen. If you have an allergy, avoid touching magnets with bare hands and opt for encased magnets.

Fire risk

Fire hazard: Rare earth powder is explosive. Avoid machining magnets in home conditions as this may cause fire.

Danger to the youngest

Always store magnets away from children. Ingestion danger is significant, and the consequences of magnets connecting inside the body are fatal.

Compass and GPS

Note: rare earth magnets generate a field that confuses sensitive sensors. Keep a separation from your phone, device, and GPS.

Protective goggles

Watch out for shards. Magnets can explode upon violent connection, launching sharp fragments into the air. Eye protection is mandatory.

Pacemakers

Health Alert: Strong magnets can deactivate pacemakers and defibrillators. Stay away if you have electronic implants.

Heat sensitivity

Standard neodymium magnets (grade N) undergo demagnetization when the temperature surpasses 80°C. Damage is permanent.

Attention! More info about risks in the article: Safety of working with magnets.