SM 18x275 [2xM5] / N42 - magnetic separator
magnetic separator
Catalog no 130276
GTIN/EAN: 5906301812784
- Diameter Ø
- 18 mm [±1 mm]
- Height
- 275 mm [±1 mm]
- Weight
- 0.01 g
- Magnetic Flux
- ~ 5 400 Gauss [±5%]
How we measure these parameters — certificates and measurements
495.00 zł net / pcs
608.85 zł with VAT (23% VAT) / pcs
bulk discounts:
Need more?Frequently asked questions
Which rod should I choose for fine contamination?
Which rod pitch should I choose?
Why does efficiency drop after a few weeks of operation?
Call us now
+48 888 99 98 98
alternatively let us know using
contact form
the contact section.
Specifications and structure of a neodymium magnet can be estimated using our
power calculator.
Order by 14:00 and we’ll ship today!
Technical specification - SM 18x275 [2xM5] / N42 - magnetic separator
Specification / characteristics - SM 18x275 [2xM5] / N42 - magnetic separator
| properties | values |
|---|---|
| Cat. no. | 130276 |
| GTIN/EAN | 5906301812784 |
| Production/Distribution | Dhit sp. z o.o. |
| Country of origin | Poland / China / Germany |
| Customs code | 85059029 |
| Diameter Ø | 18 mm [±1 mm] |
| Height | 275 mm [±1 mm] |
| Weight | 0.01 g |
| Material Type | Stainless steel AISI 304 / A2 |
| Magnetic Flux | ~ 5 400 Gauss [±5%] |
| Size/Mount Quantity | 2xM5 |
| Polarity | circumferential - 12 poles |
| Casing Tube Thickness | 1 mm |
| Manufacturing Tolerance | ±1 mm |
Magnetic properties of material N42
| properties | values | units |
|---|---|---|
| Remanence Br ? | 12.9-13.2 | kGs |
| Remanence Br ? | 1290-1320 | mT |
| Coercivity bHc ? | 10.8-12.0 | kOe |
| Coercivity bHc ? | 860-955 | kA/m |
| Intrinsic coercivity iHc | ≥ 12 | kOe |
| Intrinsic coercivity iHc | ≥ 955 | kA/m |
| Energy product BHmax ? | 40-42 | BH max MGOe |
| Energy product BHmax ? | 318-334 | BH max KJ/m |
| Maximum working temperature ? | ≤ 80 | °C |
Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C
| properties | values | units |
|---|---|---|
| Vickers hardness | ≥550 | Hv |
| Density | ≥7.4 | g/cm3 |
| Curie Temperature TC | 310 | °C |
| Curie Temperature TF | 590 | °F |
| Specific resistance | 150 | μΩ⋅cm |
| Bending strength | 250 | MPa |
| Compressive strength | 1000~1100 | MPa |
| Thermal expansion parallel (∥) to orientation (M) | (3-4) x 10-6 | °C-1 |
| Thermal expansion perpendicular (⊥) to orientation (M) | -(1-3) x 10-6 | °C-1 |
| Young's modulus | 1.7 x 104 | kg/mm² |
Table 1: Rod construction
SM 18x275 [2xM5] / N42
| Parameter | Value | Description / Unit |
|---|---|---|
| Diameter (Ø) | 18 | mm |
| Total length | 275 | mm (L) |
| Active length | 239 | mm |
| Section count | 10 | modules |
| Dead zone | 36 | mm (2x 18mm starter) |
| Weight (est.) | ~532 | g |
| Active area | 135 | cm² (Area) |
| Housing material | AISI 304 | 1.4301 (Inox) |
| Surface finish | Ra < 0.8 µm | Polished |
| Temp. class | 80°C | Standard (N) |
| Force loss (at max °C) | -12.8% | Reversible loss (physics) |
| Force (calculated) | 3.8 | kg (theor.) |
| Induction (surface) | ~5 400 | Gauss (Max) |
Chart 2: Field profile (10 sections)
Chart 3: Temperature performance
Elemental analysis
| iron (Fe) | 64% – 68% |
| neodymium (Nd) | 29% – 32% |
| boron (B) | 1.1% – 1.2% |
| dysprosium (Dy) | 0.5% – 2.0% |
| coating (Ni-Cu-Ni) | < 0.05% |
Sustainability
| recyclability (EoL) | 100% |
| recycled raw materials | ~10% (pre-cons) |
| carbon footprint | low / zredukowany |
| waste code (EWC) | 16 02 16 |
Other products
Strengths as well as weaknesses of rare earth magnets.
Strengths
- They virtually do not lose strength, because even after 10 years the decline in efficiency is only ~1% (in laboratory conditions),
- They are extremely resistant to demagnetization induced by external magnetic fields,
- A magnet with a shiny nickel surface is more attractive,
- Magnetic induction on the top side of the magnet turns out to be exceptional,
- Made from properly selected components, these magnets show impressive resistance to high heat, enabling them to function (depending on their shape) at temperatures up to 230°C and above...
- In view of the ability of precise forming and adaptation to specialized needs, neodymium magnets can be manufactured in a variety of geometric configurations, which amplifies use scope,
- Fundamental importance in modern technologies – they serve a role in hard drives, electric drive systems, medical devices, as well as industrial machines.
- Relatively small size with high pulling force – neodymium magnets offer strong magnetic field in tiny dimensions, which makes them useful in miniature devices
Cons
- They are fragile upon too strong impacts. To avoid cracks, it is worth protecting magnets in special housings. Such protection not only shields the magnet but also improves its resistance to damage
- When exposed to high temperature, neodymium magnets suffer a drop in power. Often, when the temperature exceeds 80°C, their power decreases (depending on the size and shape of the magnet). For those who need magnets for extreme conditions, we offer [AH] versions withstanding up to 230°C
- Magnets exposed to a humid environment can corrode. Therefore during using outdoors, we advise using waterproof magnets made of rubber, plastic or other material protecting against moisture
- Due to limitations in realizing threads and complicated shapes in magnets, we recommend using a housing - magnetic mechanism.
- Health risk resulting from small fragments of magnets are risky, when accidentally swallowed, which is particularly important in the context of child safety. Additionally, tiny parts of these products are able to be problematic in diagnostics medical in case of swallowing.
- Higher cost of purchase is one of the disadvantages compared to ceramic magnets, especially in budget applications
Pull force analysis
Breakaway strength of the magnet in ideal conditions – what contributes to it?
- using a base made of high-permeability steel, serving as a magnetic yoke
- whose transverse dimension reaches at least 10 mm
- with an ideally smooth contact surface
- under conditions of no distance (surface-to-surface)
- for force acting at a right angle (pull-off, not shear)
- in neutral thermal conditions
Lifting capacity in real conditions – factors
- Gap (between the magnet and the metal), because even a microscopic distance (e.g. 0.5 mm) results in a drastic drop in lifting capacity by up to 50% (this also applies to paint, rust or debris).
- Force direction – remember that the magnet holds strongest perpendicularly. Under sliding down, the holding force drops significantly, often to levels of 20-30% of the nominal value.
- Metal thickness – the thinner the sheet, the weaker the hold. Part of the magnetic field passes through the material instead of generating force.
- Metal type – not every steel reacts the same. High carbon content worsen the interaction with the magnet.
- Smoothness – ideal contact is obtained only on polished steel. Rough texture create air cushions, reducing force.
- Temperature influence – hot environment weakens pulling force. Too high temperature can permanently demagnetize the magnet.
Lifting capacity was determined using a polished steel plate of suitable thickness (min. 20 mm), under perpendicular pulling force, whereas under parallel forces the lifting capacity is smaller. Moreover, even a small distance between the magnet’s surface and the plate reduces the load capacity.
Safety rules for work with neodymium magnets
Dust is flammable
Fire hazard: Neodymium dust is explosive. Do not process magnets in home conditions as this may cause fire.
Swallowing risk
Neodymium magnets are not suitable for play. Swallowing multiple magnets can lead to them pinching intestinal walls, which constitutes a critical condition and necessitates immediate surgery.
GPS and phone interference
GPS units and mobile phones are highly susceptible to magnetic fields. Direct contact with a powerful NdFeB magnet can decalibrate the sensors in your phone.
Metal Allergy
Medical facts indicate that nickel (standard magnet coating) is a potent allergen. If your skin reacts to metals, avoid direct skin contact and select encased magnets.
Warning for heart patients
Individuals with a pacemaker have to keep an large gap from magnets. The magnetic field can disrupt the operation of the life-saving device.
Electronic hazard
Device Safety: Neodymium magnets can damage data carriers and sensitive devices (pacemakers, medical aids, mechanical watches).
Bone fractures
Pinching hazard: The pulling power is so great that it can cause blood blisters, crushing, and broken bones. Protective gloves are recommended.
Shattering risk
Despite the nickel coating, neodymium is delicate and cannot withstand shocks. Do not hit, as the magnet may crumble into hazardous fragments.
Thermal limits
Keep cool. NdFeB magnets are susceptible to heat. If you need resistance above 80°C, inquire about HT versions (H, SH, UH).
Conscious usage
Handle magnets with awareness. Their immense force can shock even professionals. Plan your moves and do not underestimate their power.