UMGZ 48x24x11.5 [M8] GZ / N38 - magnetic holder external thread
magnetic holder external thread
Catalog no 190415
GTIN/EAN: 5906301813866
- Diameter Ø
- 48 mm [±1 mm]
- Height
- 24 mm [±1 mm]
- Height
- 11.5 mm [±1 mm]
- Weight
- 140 g
- Magnetization Direction
- ↑ axial
- Coating
- [NiCuNi] Nickel
How we measure these parameters — certificates and measurements
48.70 zł net / pcs
59.90 zł with VAT (23% VAT) / pcs
bulk discounts:
Need more?Frequently asked questions
Which magnetic holder is suitable for moving metal parts in a workshop?
How do I choose a holder for hanging a heavy item and check its real grip?
Which magnetic holders can be used outdoors?
How should I choose a strong threaded holder for field work?
Call us now
+48 888 99 98 98
alternatively let us know using
contact form
the contact section.
Specifications and structure of a neodymium magnet can be estimated using our
power calculator.
Order by 14:00 and we’ll ship today!
Physical properties - UMGZ 48x24x11.5 [M8] GZ / N38 - magnetic holder external thread
Specification / characteristics - UMGZ 48x24x11.5 [M8] GZ / N38 - magnetic holder external thread
| properties | values |
|---|---|
| Cat. no. | 190415 |
| GTIN/EAN | 5906301813866 |
| Distributor | Dhit sp. z o.o. |
| Country of origin | Poland / China / Germany |
| Customs code | 85059029 |
| Diameter Ø | 48 mm [±1 mm] |
| Height | 24 mm [±1 mm] |
| Height | 11.5 mm [±1 mm] |
| Weight | 140 g |
| Magnetization Direction | ↑ axial |
| Load capacity ~ ? | 80.00 kg / 784.53 N |
| Coating | [NiCuNi] Nickel |
| Manufacturing Tolerance | ±1 mm |
Magnetic properties of material N38
| properties | values | units |
|---|---|---|
| Remanence Br ? | 12.2-12.6 | kGs |
| Remanence Br ? | 1220-1260 | mT |
| Coercivity bHc ? | 10.8-11.5 | kOe |
| Coercivity bHc ? | 860-915 | kA/m |
| Intrinsic coercivity iHc | ≥ 12 | kOe |
| Intrinsic coercivity iHc | ≥ 955 | kA/m |
| Energy product BHmax ? | 36-38 | BH max MGOe |
| Energy product BHmax ? | 287-303 | BH max KJ/m |
| Maximum working temperature ? | ≤ 80 | °C |
Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C
| properties | values | units |
|---|---|---|
| Vickers hardness | ≥550 | Hv |
| Density | ≥7.4 | g/cm3 |
| Curie Temperature TC | 310 | °C |
| Curie Temperature TF | 590 | °F |
| Specific resistance | 150 | μΩ⋅cm |
| Bending strength | 250 | MPa |
| Compressive strength | 1000~1100 | MPa |
| Thermal expansion parallel (∥) to orientation (M) | (3-4) x 10-6 | °C-1 |
| Thermal expansion perpendicular (⊥) to orientation (M) | -(1-3) x 10-6 | °C-1 |
| Young's modulus | 1.7 x 104 | kg/mm² |
Elemental analysis
| iron (Fe) | 64% – 68% |
| neodymium (Nd) | 29% – 32% |
| boron (B) | 1.1% – 1.2% |
| dysprosium (Dy) | 0.5% – 2.0% |
| coating (Ni-Cu-Ni) | < 0.05% |
Environmental data
| recyclability (EoL) | 100% |
| recycled raw materials | ~10% (pre-cons) |
| carbon footprint | low / zredukowany |
| waste code (EWC) | 16 02 16 |
View more deals
Pros as well as cons of neodymium magnets.
Benefits
- They retain full power for nearly ten years – the loss is just ~1% (according to analyses),
- They are resistant to demagnetization induced by external field influence,
- By using a smooth layer of gold, the element gains an aesthetic look,
- Magnets are distinguished by very high magnetic induction on the outer side,
- Thanks to resistance to high temperature, they are capable of working (depending on the shape) even at temperatures up to 230°C and higher...
- Thanks to versatility in constructing and the ability to customize to individual projects,
- Fundamental importance in future technologies – they are commonly used in magnetic memories, motor assemblies, diagnostic systems, also other advanced devices.
- Relatively small size with high pulling force – neodymium magnets offer high power in compact dimensions, which enables their usage in compact constructions
Limitations
- Susceptibility to cracking is one of their disadvantages. Upon intense impact they can break. We recommend keeping them in a special holder, which not only secures them against impacts but also raises their durability
- Do not exceed this material temperature limit: 80°C. Overheating may permanently weaken the magnet.
- When exposed to humidity, magnets start to rust. To use them in conditions outside, it is recommended to use protective magnets, such as magnets in rubber or plastics, which secure oxidation as well as corrosion.
- Due to limitations in realizing nuts and complex forms in magnets, we recommend using casing - magnetic mount.
- Health risk to health – tiny shards of magnets are risky, when accidentally swallowed, which gains importance in the aspect of protecting the youngest. It is also worth noting that small components of these devices are able to complicate diagnosis medical in case of swallowing.
- Due to expensive raw materials, their price is relatively high,
Pull force analysis
Maximum lifting force for a neodymium magnet – what contributes to it?
- using a sheet made of mild steel, functioning as a magnetic yoke
- with a thickness minimum 10 mm
- with a surface free of scratches
- with zero gap (no impurities)
- for force applied at a right angle (pull-off, not shear)
- at ambient temperature room level
Determinants of lifting force in real conditions
- Clearance – existence of any layer (paint, tape, gap) acts as an insulator, which lowers power steeply (even by 50% at 0.5 mm).
- Force direction – catalog parameter refers to pulling vertically. When attempting to slide, the magnet exhibits significantly lower power (often approx. 20-30% of nominal force).
- Substrate thickness – for full efficiency, the steel must be sufficiently thick. Thin sheet limits the attraction force (the magnet "punches through" it).
- Plate material – low-carbon steel attracts best. Alloy admixtures reduce magnetic properties and holding force.
- Surface quality – the smoother and more polished the surface, the larger the contact zone and stronger the hold. Unevenness creates an air distance.
- Thermal environment – heating the magnet results in weakening of induction. It is worth remembering the thermal limit for a given model.
Lifting capacity was assessed using a smooth steel plate of suitable thickness (min. 20 mm), under perpendicular pulling force, however under parallel forces the holding force is lower. Additionally, even a slight gap between the magnet’s surface and the plate lowers the load capacity.
H&S for magnets
Permanent damage
Do not exceed the maximum operating temperature stated in the specifications of the particular product. The limit depends on the material, geometry and operating arrangement; there is no single threshold for all neodymium magnets. Overheating can permanently weaken a magnet.
Choking Hazard
These products are not intended for children. Eating a few magnets can lead to them pinching intestinal walls, which poses a direct threat to life and necessitates urgent medical intervention.
Compass and GPS
A strong magnetic field disrupts the operation of compasses in smartphones and navigation systems. Keep magnets close to a smartphone to avoid damaging the sensors.
Combustion hazard
Dust created during cutting of magnets is flammable. Avoid drilling into magnets without proper cooling and knowledge.
Threat to electronics
Data protection: Strong magnets can damage payment cards and sensitive devices (pacemakers, medical aids, mechanical watches).
Skin irritation risks
Allergy Notice: The nickel-copper-nickel coating consists of nickel. If skin irritation appears, immediately stop handling magnets and use protective gear.
Caution required
Handle magnets with awareness. Their powerful strength can surprise even professionals. Be vigilant and respect their force.
Magnets are brittle
Despite metallic appearance, the material is brittle and not impact-resistant. Avoid impacts, as the magnet may crumble into hazardous fragments.
Bodily injuries
Risk of injury: The pulling power is so immense that it can result in blood blisters, pinching, and even bone fractures. Protective gloves are recommended.
Health Danger
Warning for patients: Strong magnetic fields affect medical devices. Maintain minimum 30 cm distance or request help to handle the magnets.
