MW 7x2 / N38 - cylindrical magnet
cylindrical magnet
Catalog no 010099
GTIN/EAN: 5906301810988
- Diameter Ø
- 7 mm [±0,1 mm]
- Height
- 2 mm [±0,1 mm]
- Weight
- 0.58 g
- Magnetization Direction
- ↑ axial
- Coating
- [NiCuNi] Nickel
How we measure these parameters — certificates and measurements
0.310 zł net / pcs
0.381 zł with VAT (23% VAT) / pcs
bulk discounts:
Need more?Frequently asked questions
What is the maximum working temperature of a disc magnet?
What is the difference between N38, N42 and N52?
What is the dimensional tolerance?
Engineering report for this magnet
Full PDF analysis: pull and shear force, effect of distance, temperature and plate thickness, safety distances and the demagnetization curve.
Call us now
+48 888 99 98 98
alternatively let us know using
contact form
the contact section.
Specifications and structure of a neodymium magnet can be estimated using our
power calculator.
Order by 14:00 and we’ll ship today!
Technical details - MW 7x2 / N38 - cylindrical magnet
Specification / characteristics - MW 7x2 / N38 - cylindrical magnet
| properties | values |
|---|---|
| Cat. no. | 010099 |
| GTIN/EAN | 5906301810988 |
| Production/Distribution | Dhit sp. z o.o. |
| Country of origin | Poland / China / Germany |
| Customs code | 85059029 |
| Diameter Ø | 7 mm [±0,1 mm] |
| Height | 2 mm [±0,1 mm] |
| Weight | 0.58 g |
| Magnetization Direction | ↑ axial |
| Load capacity ~ ? | 0.99 kg / 9.76 N |
| Magnetic Induction ~ ? | 307.23 mT / 3072 Gs |
| Coating | [NiCuNi] Nickel |
| Manufacturing Tolerance | ±0.1 mm |
Magnetic properties of material N38
| properties | values | units |
|---|---|---|
| Remanence Br ? | 12.2-12.6 | kGs |
| Remanence Br ? | 1220-1260 | mT |
| Coercivity bHc ? | 10.8-11.5 | kOe |
| Coercivity bHc ? | 860-915 | kA/m |
| Intrinsic coercivity iHc | ≥ 12 | kOe |
| Intrinsic coercivity iHc | ≥ 955 | kA/m |
| Energy product BHmax ? | 36-38 | BH max MGOe |
| Energy product BHmax ? | 287-303 | BH max KJ/m |
| Maximum working temperature ? | ≤ 80 | °C |
Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C
| properties | values | units |
|---|---|---|
| Vickers hardness | ≥550 | Hv |
| Density | ≥7.4 | g/cm3 |
| Curie Temperature TC | 310 | °C |
| Curie Temperature TF | 590 | °F |
| Specific resistance | 150 | μΩ⋅cm |
| Bending strength | 250 | MPa |
| Compressive strength | 1000~1100 | MPa |
| Thermal expansion parallel (∥) to orientation (M) | (3-4) x 10-6 | °C-1 |
| Thermal expansion perpendicular (⊥) to orientation (M) | -(1-3) x 10-6 | °C-1 |
| Young's modulus | 1.7 x 104 | kg/mm² |
Engineering simulation of the product - technical parameters
The following information represent the outcome of a engineering simulation. Values were calculated on algorithms for the material Nd2Fe14B. Operational performance may differ from theoretical values. Please consider these calculations as a preliminary roadmap during assembly planning.
Table 1: Static pull force (force vs gap) - characteristics
MW 7x2 / N38
| Distance (mm) | Induction (Gauss) / mT | Pull Force (kg/lbs/g/N) | Risk Status |
|---|---|---|---|
| 0 mm |
3070 Gs
307.0 mT
|
0.99 kg / 2.18 lbs
990.0 g / 9.7 N
|
weak grip |
| 1 mm |
2332 Gs
233.2 mT
|
0.57 kg / 1.26 lbs
571.1 g / 5.6 N
|
weak grip |
| 2 mm |
1590 Gs
159.0 mT
|
0.27 kg / 0.59 lbs
265.5 g / 2.6 N
|
weak grip |
| 3 mm |
1044 Gs
104.4 mT
|
0.11 kg / 0.25 lbs
114.6 g / 1.1 N
|
weak grip |
| 5 mm |
466 Gs
46.6 mT
|
0.02 kg / 0.05 lbs
22.8 g / 0.2 N
|
weak grip |
| 10 mm |
100 Gs
10.0 mT
|
0.00 kg / 0.00 lbs
1.1 g / 0.0 N
|
weak grip |
| 15 mm |
35 Gs
3.5 mT
|
0.00 kg / 0.00 lbs
0.1 g / 0.0 N
|
weak grip |
| 20 mm |
16 Gs
1.6 mT
|
0.00 kg / 0.00 lbs
0.0 g / 0.0 N
|
weak grip |
| 30 mm |
5 Gs
0.5 mT
|
0.00 kg / 0.00 lbs
0.0 g / 0.0 N
|
weak grip |
| 50 mm |
1 Gs
0.1 mT
|
0.00 kg / 0.00 lbs
0.0 g / 0.0 N
|
weak grip |
Table 2: Shear capacity (vertical surface)
MW 7x2 / N38
| Distance (mm) | Friction coefficient | Pull Force (kg/lbs/g/N) |
|---|---|---|
| 0 mm | Stal (~0.2) |
0.20 kg / 0.44 lbs
198.0 g / 1.9 N
|
| 1 mm | Stal (~0.2) |
0.11 kg / 0.25 lbs
114.0 g / 1.1 N
|
| 2 mm | Stal (~0.2) |
0.05 kg / 0.12 lbs
54.0 g / 0.5 N
|
| 3 mm | Stal (~0.2) |
0.02 kg / 0.05 lbs
22.0 g / 0.2 N
|
| 5 mm | Stal (~0.2) |
0.00 kg / 0.01 lbs
4.0 g / 0.0 N
|
| 10 mm | Stal (~0.2) |
0.00 kg / 0.00 lbs
0.0 g / 0.0 N
|
| 15 mm | Stal (~0.2) |
0.00 kg / 0.00 lbs
0.0 g / 0.0 N
|
| 20 mm | Stal (~0.2) |
0.00 kg / 0.00 lbs
0.0 g / 0.0 N
|
| 30 mm | Stal (~0.2) |
0.00 kg / 0.00 lbs
0.0 g / 0.0 N
|
| 50 mm | Stal (~0.2) |
0.00 kg / 0.00 lbs
0.0 g / 0.0 N
|
Table 3: Wall mounting (shearing) - vertical pull
MW 7x2 / N38
| Surface type | Friction coefficient / % Mocy | Max load (kg/lbs/g/N) |
|---|---|---|
| Raw steel |
µ = 0.3
30% Nominalnej Siły
|
0.30 kg / 0.65 lbs
297.0 g / 2.9 N
|
| Painted steel (standard) |
µ = 0.2
20% Nominalnej Siły
|
0.20 kg / 0.44 lbs
198.0 g / 1.9 N
|
| Oily/slippery steel |
µ = 0.1
10% Nominalnej Siły
|
0.10 kg / 0.22 lbs
99.0 g / 1.0 N
|
| Magnet with anti-slip rubber |
µ = 0.5
50% Nominalnej Siły
|
0.50 kg / 1.09 lbs
495.0 g / 4.9 N
|
Table 4: Material efficiency (saturation) - sheet metal selection
MW 7x2 / N38
| Steel thickness (mm) | % power | Real pull force (kg/lbs/g/N) |
|---|---|---|
| 0.5 mm |
|
0.10 kg / 0.22 lbs
99.0 g / 1.0 N
|
| 1 mm |
|
0.25 kg / 0.55 lbs
247.5 g / 2.4 N
|
| 2 mm |
|
0.50 kg / 1.09 lbs
495.0 g / 4.9 N
|
| 3 mm |
|
0.74 kg / 1.64 lbs
742.5 g / 7.3 N
|
| 5 mm |
|
0.99 kg / 2.18 lbs
990.0 g / 9.7 N
|
| 10 mm |
|
0.99 kg / 2.18 lbs
990.0 g / 9.7 N
|
| 11 mm |
|
0.99 kg / 2.18 lbs
990.0 g / 9.7 N
|
| 12 mm |
|
0.99 kg / 2.18 lbs
990.0 g / 9.7 N
|
Table 5: Thermal stability (stability) - thermal limit
MW 7x2 / N38
| Ambient temp. (°C) | Power loss | Remaining pull (kg/lbs/g/N) | Status |
|---|---|---|---|
| 20 °C | 0.0% |
0.99 kg / 2.18 lbs
990.0 g / 9.7 N
|
OK |
| 40 °C | -2.2% |
0.97 kg / 2.13 lbs
968.2 g / 9.5 N
|
OK |
| 60 °C | -4.4% |
0.95 kg / 2.09 lbs
946.4 g / 9.3 N
|
|
| 80 °C | -6.6% |
0.92 kg / 2.04 lbs
924.7 g / 9.1 N
|
|
| 100 °C | -28.8% |
0.70 kg / 1.55 lbs
704.9 g / 6.9 N
|
Table 6: Two magnets (repulsion) - forces in the system
MW 7x2 / N38
| Gap (mm) | Attraction (kg/lbs) (N-S) | Sliding Force (kg/lbs/g/N) | Repulsion (kg/lbs) (N-N) |
|---|---|---|---|
| 0 mm |
2.24 kg / 4.93 lbs
4 653 Gs
|
0.34 kg / 0.74 lbs
335 g / 3.3 N
|
N/A |
| 1 mm |
1.76 kg / 3.89 lbs
5 454 Gs
|
0.26 kg / 0.58 lbs
265 g / 2.6 N
|
1.59 kg / 3.50 lbs
~0 Gs
|
| 2 mm |
1.29 kg / 2.84 lbs
4 663 Gs
|
0.19 kg / 0.43 lbs
193 g / 1.9 N
|
1.16 kg / 2.56 lbs
~0 Gs
|
| 3 mm |
0.89 kg / 1.97 lbs
3 884 Gs
|
0.13 kg / 0.30 lbs
134 g / 1.3 N
|
0.81 kg / 1.77 lbs
~0 Gs
|
| 5 mm |
0.40 kg / 0.87 lbs
2 581 Gs
|
0.06 kg / 0.13 lbs
59 g / 0.6 N
|
0.36 kg / 0.78 lbs
~0 Gs
|
| 10 mm |
0.05 kg / 0.11 lbs
932 Gs
|
0.01 kg / 0.02 lbs
8 g / 0.1 N
|
0.05 kg / 0.10 lbs
~0 Gs
|
| 20 mm |
0.00 kg / 0.01 lbs
200 Gs
|
0.00 kg / 0.00 lbs
0 g / 0.0 N
|
0.00 kg / 0.00 lbs
~0 Gs
|
| 50 mm |
0.00 kg / 0.00 lbs
17 Gs
|
0.00 kg / 0.00 lbs
0 g / 0.0 N
|
0.00 kg / 0.00 lbs
~0 Gs
|
| 60 mm |
0.00 kg / 0.00 lbs
10 Gs
|
0.00 kg / 0.00 lbs
0 g / 0.0 N
|
0.00 kg / 0.00 lbs
~0 Gs
|
| 70 mm |
0.00 kg / 0.00 lbs
6 Gs
|
0.00 kg / 0.00 lbs
0 g / 0.0 N
|
0.00 kg / 0.00 lbs
~0 Gs
|
| 80 mm |
0.00 kg / 0.00 lbs
4 Gs
|
0.00 kg / 0.00 lbs
0 g / 0.0 N
|
0.00 kg / 0.00 lbs
~0 Gs
|
| 90 mm |
0.00 kg / 0.00 lbs
3 Gs
|
0.00 kg / 0.00 lbs
0 g / 0.0 N
|
0.00 kg / 0.00 lbs
~0 Gs
|
| 100 mm |
0.00 kg / 0.00 lbs
2 Gs
|
0.00 kg / 0.00 lbs
0 g / 0.0 N
|
0.00 kg / 0.00 lbs
~0 Gs
|
Table 7: Hazards (implants) - precautionary measures
MW 7x2 / N38
| Object / Device | Limit (Gauss) / mT | Safe distance |
|---|---|---|
| Pacemaker | 5 Gs (0.5 mT) | 3.5 cm |
| Hearing aid | 10 Gs (1.0 mT) | 2.5 cm |
| Timepiece | 20 Gs (2.0 mT) | 2.0 cm |
| Phone / Smartphone | 40 Gs (4.0 mT) | 1.5 cm |
| Car key | 50 Gs (5.0 mT) | 1.5 cm |
| Payment card | 400 Gs (40.0 mT) | 1.0 cm |
| HDD hard drive | 600 Gs (60.0 mT) | 0.5 cm |
Table 8: Dynamics (cracking risk) - warning
MW 7x2 / N38
| Start from (mm) | Speed (km/h) | Energy (J) | Predicted outcome |
|---|---|---|---|
| 10 mm |
25.73 km/h
(7.15 m/s)
|
0.01 J | |
| 30 mm |
25.75 km/h
(7.15 m/s)
|
0.01 J | |
| 50 mm |
25.75 km/h
(7.15 m/s)
|
0.01 J | |
| 100 mm |
25.75 km/h
(7.15 m/s)
|
0.01 J |
Table 9: Coating parameters (durability)
MW 7x2 / N38
| Technical parameter | Value / Description |
|---|---|
| Coating type | [NiCuNi] Nickel |
| Layer structure | Nickel - Copper - Nickel |
| Layer thickness | 10-20 µm |
| Salt spray test (SST) ? | 24 h |
| Recommended environment | Indoors only (dry) |
Table 10: Construction data (Flux)
MW 7x2 / N38
| Parameter | Value | SI Unit / Description |
|---|---|---|
| Magnetic Flux | 1 284 Mx | 12.8 µWb |
| Pc Coefficient | 0.39 | Low (Flat) |
Table 11: Underwater work (magnet fishing)
MW 7x2 / N38
| Environment | Effective steel pull | Effect |
|---|---|---|
| Air (land) | 0.99 kg | Standard |
| Water (riverbed) |
1.13 kg
(+0.14 kg buoyancy gain)
|
+14.5% |
1. Shear force
*Caution: On a vertical surface, the magnet retains just a fraction of its nominal pull.
2. Plate thickness effect
*Thin metal sheet (e.g. computer case) severely weakens the holding force.
3. Power loss vs temp
*For N38 material, the max working temp is 80°C.
4. Demagnetization curve and operating point (B-H)
chart generated for the permeance coefficient Pc (Permeance Coefficient) = 0.39
This simulation demonstrates the magnetic stability of the selected magnet under specific geometric conditions. The solid red line represents the demagnetization curve (material potential), while the dashed blue line is the load line based on the magnet's geometry. The Pc (Permeance Coefficient), also known as the load line slope, is a dimensionless value that describes the relationship between the magnet's shape and its magnetic stability. The intersection of these two lines (the black dot) is the operating point — it determines the actual magnetic flux density generated by the magnet in this specific configuration. A higher Pc value means the magnet is more 'slender' (tall relative to its area), resulting in a higher operating point and better resistance to irreversible demagnetization caused by external fields or temperature. A value of 0.42 is relatively low (typical for flat magnets), meaning the operating point is closer to the 'knee' of the curve — caution is advised when operating at temperatures near the maximum limit to avoid strength loss.
Elemental analysis
| iron (Fe) | 64% – 68% |
| neodymium (Nd) | 29% – 32% |
| boron (B) | 1.1% – 1.2% |
| dysprosium (Dy) | 0.5% – 2.0% |
| coating (Ni-Cu-Ni) | < 0.05% |
Environmental data
| recyclability (EoL) | 100% |
| recycled raw materials | ~10% (pre-cons) |
| carbon footprint | low / zredukowany |
| waste code (EWC) | 16 02 16 |
Other products
Advantages and disadvantages of neodymium magnets.
Benefits
- They do not lose magnetism, even over around 10 years – the drop in strength is only ~1% (theoretically),
- They possess excellent resistance to magnetic field loss due to external magnetic sources,
- Thanks to the shimmering finish, the plating of Ni-Cu-Ni, gold-plated, or silver-plated gives an modern appearance,
- They are known for high magnetic induction at the operating surface, making them more effective,
- Thanks to resistance to high temperature, they can operate (depending on the form) even at temperatures up to 230°C and higher...
- Thanks to freedom in forming and the ability to adapt to unusual requirements,
- Universal use in high-tech industry – they serve a role in mass storage devices, motor assemblies, diagnostic systems, and modern systems.
- Relatively small size with high pulling force – neodymium magnets offer strong magnetic field in compact dimensions, which makes them useful in small systems
Disadvantages
- They are prone to damage upon too strong impacts. To avoid cracks, it is worth protecting magnets using a steel holder. Such protection not only shields the magnet but also improves its resistance to damage
- We warn that neodymium magnets can lose their power at high temperatures. To prevent this, we advise our specialized [AH] magnets, which work effectively even at 230°C.
- When exposed to humidity, magnets usually rust. To use them in conditions outside, it is recommended to use protective magnets, such as magnets in rubber or plastics, which secure oxidation as well as corrosion.
- Due to limitations in realizing nuts and complicated forms in magnets, we recommend using cover - magnetic mechanism.
- Health risk related to microscopic parts of magnets are risky, in case of ingestion, which becomes key in the aspect of protecting the youngest. Additionally, small elements of these products can complicate diagnosis medical in case of swallowing.
- High unit price – neodymium magnets cost more than other types of magnets (e.g. ferrite), which increases costs of application in large quantities
Holding force characteristics
Maximum lifting force for a neodymium magnet – what contributes to it?
- with the use of a sheet made of low-carbon steel, ensuring maximum field concentration
- whose thickness is min. 10 mm
- with a surface free of scratches
- without any air gap between the magnet and steel
- for force acting at a right angle (pull-off, not shear)
- in temp. approx. 20°C
Practical lifting capacity: influencing factors
- Gap (betwixt the magnet and the metal), because even a microscopic clearance (e.g. 0.5 mm) can cause a drastic drop in force by up to 50% (this also applies to varnish, rust or debris).
- Loading method – catalog parameter refers to detachment vertically. When slipping, the magnet holds much less (typically approx. 20-30% of maximum force).
- Base massiveness – too thin sheet does not close the flux, causing part of the flux to be escaped into the air.
- Material type – ideal substrate is high-permeability steel. Stainless steels may generate lower lifting capacity.
- Smoothness – full contact is possible only on smooth steel. Rough texture create air cushions, weakening the magnet.
- Thermal factor – hot environment reduces pulling force. Exceeding the limit temperature can permanently damage the magnet.
Holding force was tested on the plate surface of 20 mm thickness, when a perpendicular force was applied, whereas under parallel forces the lifting capacity is smaller. Additionally, even a small distance between the magnet’s surface and the plate lowers the lifting capacity.
Warnings
Swallowing risk
Product intended for adults. Small elements pose a choking risk, leading to intestinal necrosis. Store out of reach of kids and pets.
Medical interference
For implant holders: Strong magnetic fields affect medical devices. Maintain minimum 30 cm distance or request help to handle the magnets.
Fire warning
Dust generated during grinding of magnets is self-igniting. Avoid drilling into magnets unless you are an expert.
Safe operation
Use magnets with awareness. Their huge power can surprise even experienced users. Plan your moves and do not underestimate their force.
Keep away from electronics
GPS units and smartphones are extremely sensitive to magnetic fields. Direct contact with a powerful NdFeB magnet can decalibrate the internal compass in your phone.
Safe distance
Do not bring magnets close to a wallet, computer, or screen. The magnetic field can irreversibly ruin these devices and wipe information from cards.
Crushing risk
Big blocks can break fingers in a fraction of a second. Never place your hand between two attracting surfaces.
Maximum temperature
Control the heat. Heating the magnet to high heat will ruin its magnetic structure and strength.
Magnet fragility
Watch out for shards. Magnets can explode upon violent connection, launching shards into the air. Eye protection is mandatory.
Nickel coating and allergies