MW 10x2 zestaw 10 szt. / N38 - cylindrical magnet
cylindrical magnet
Catalog no 010529
GTIN/EAN: 5906301815204
- Diameter Ø
- 10 mm [±0,1 mm]
- Height
- 2 mm [±0,1 mm]
- Weight
- 11.8 g
- Magnetization Direction
- ↑ axial
- Coating
- [NiCuNi] Nickel
How we measure these parameters — certificates and measurements
5.60 zł net / pcs
6.89 zł with VAT (23% VAT) / pcs
bulk discounts:
Need more?Frequently asked questions
Where can I buy strong cylindrical neodymium magnets?
Can a small cylindrical magnet provide a strong grip for precise workshop work?
Which cylindrical magnet can work at a higher temperature?
Engineering report for this magnet
Full PDF analysis: pull and shear force, effect of distance, temperature and plate thickness, safety distances and the demagnetization curve.
Call us now
+48 888 99 98 98
alternatively let us know using
contact form
the contact section.
Specifications and structure of a neodymium magnet can be estimated using our
power calculator.
Order by 14:00 and we’ll ship today!
Technical parameters of the product - MW 10x2 zestaw 10 szt. / N38 - cylindrical magnet
Specification / characteristics - MW 10x2 zestaw 10 szt. / N38 - cylindrical magnet
| properties | values |
|---|---|
| Cat. no. | 010529 |
| GTIN/EAN | 5906301815204 |
| Distributor | Dhit sp. z o.o. |
| Country of origin | Poland / China / Germany |
| Customs code | 85059029 |
| Diameter Ø | 10 mm [±0,1 mm] |
| Height | 2 mm [±0,1 mm] |
| Weight | 11.8 g |
| Magnetization Direction | ↑ axial |
| Load capacity ~ ? | 1.27 kg / 12.50 N |
| Magnetic Induction ~ ? | 230.11 mT / 2301 Gs |
| Coating | [NiCuNi] Nickel |
| Manufacturing Tolerance | ±0.1 mm |
Magnetic properties of material N38
| properties | values | units |
|---|---|---|
| Remanence Br ? | 12.2-12.6 | kGs |
| Remanence Br ? | 1220-1260 | mT |
| Coercivity bHc ? | 10.8-11.5 | kOe |
| Coercivity bHc ? | 860-915 | kA/m |
| Intrinsic coercivity iHc | ≥ 12 | kOe |
| Intrinsic coercivity iHc | ≥ 955 | kA/m |
| Energy product BHmax ? | 36-38 | BH max MGOe |
| Energy product BHmax ? | 287-303 | BH max KJ/m |
| Maximum working temperature ? | ≤ 80 | °C |
Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C
| properties | values | units |
|---|---|---|
| Vickers hardness | ≥550 | Hv |
| Density | ≥7.4 | g/cm3 |
| Curie Temperature TC | 310 | °C |
| Curie Temperature TF | 590 | °F |
| Specific resistance | 150 | μΩ⋅cm |
| Bending strength | 250 | MPa |
| Compressive strength | 1000~1100 | MPa |
| Thermal expansion parallel (∥) to orientation (M) | (3-4) x 10-6 | °C-1 |
| Thermal expansion perpendicular (⊥) to orientation (M) | -(1-3) x 10-6 | °C-1 |
| Young's modulus | 1.7 x 104 | kg/mm² |
Physical modeling of the magnet - report
These data represent the direct effect of a physical analysis. Values rely on models for the class Nd2Fe14B. Real-world parameters may differ from theoretical values. Please consider these data as a preliminary roadmap when designing systems.
Table 1: Static force (pull vs distance) - interaction chart
MW 10x2 zestaw 10 szt. / N38
| Distance (mm) | Induction (Gauss) / mT | Pull Force (kg/lbs/g/N) | Risk Status |
|---|---|---|---|
| 0 mm |
2300 Gs
230.0 mT
|
1.27 kg / 2.80 LBS
1270.0 g / 12.5 N
|
safe |
| 1 mm |
1974 Gs
197.4 mT
|
0.94 kg / 2.06 LBS
935.3 g / 9.2 N
|
safe |
| 2 mm |
1570 Gs
157.0 mT
|
0.59 kg / 1.31 LBS
592.1 g / 5.8 N
|
safe |
| 3 mm |
1194 Gs
119.4 mT
|
0.34 kg / 0.75 LBS
342.3 g / 3.4 N
|
safe |
| 5 mm |
661 Gs
66.1 mT
|
0.10 kg / 0.23 LBS
104.9 g / 1.0 N
|
safe |
| 10 mm |
178 Gs
17.8 mT
|
0.01 kg / 0.02 LBS
7.6 g / 0.1 N
|
safe |
| 15 mm |
66 Gs
6.6 mT
|
0.00 kg / 0.00 LBS
1.1 g / 0.0 N
|
safe |
| 20 mm |
31 Gs
3.1 mT
|
0.00 kg / 0.00 LBS
0.2 g / 0.0 N
|
safe |
| 30 mm |
10 Gs
1.0 mT
|
0.00 kg / 0.00 LBS
0.0 g / 0.0 N
|
safe |
| 50 mm |
2 Gs
0.2 mT
|
0.00 kg / 0.00 LBS
0.0 g / 0.0 N
|
safe |
Table 2: Sliding capacity (vertical surface)
MW 10x2 zestaw 10 szt. / N38
| Distance (mm) | Friction coefficient | Pull Force (kg/lbs/g/N) |
|---|---|---|
| 0 mm | Raw steel (µ ≈ 0.2) |
0.25 kg / 0.56 LBS
254.0 g / 2.5 N
|
| 1 mm | Raw steel (µ ≈ 0.2) |
0.19 kg / 0.41 LBS
188.0 g / 1.8 N
|
| 2 mm | Raw steel (µ ≈ 0.2) |
0.12 kg / 0.26 LBS
118.0 g / 1.2 N
|
| 3 mm | Raw steel (µ ≈ 0.2) |
0.07 kg / 0.15 LBS
68.0 g / 0.7 N
|
| 5 mm | Raw steel (µ ≈ 0.2) |
0.02 kg / 0.04 LBS
20.0 g / 0.2 N
|
| 10 mm | Raw steel (µ ≈ 0.2) |
0.00 kg / 0.00 LBS
2.0 g / 0.0 N
|
| 15 mm | Raw steel (µ ≈ 0.2) |
0.00 kg / 0.00 LBS
0.0 g / 0.0 N
|
| 20 mm | Raw steel (µ ≈ 0.2) |
0.00 kg / 0.00 LBS
0.0 g / 0.0 N
|
| 30 mm | Raw steel (µ ≈ 0.2) |
0.00 kg / 0.00 LBS
0.0 g / 0.0 N
|
| 50 mm | Raw steel (µ ≈ 0.2) |
0.00 kg / 0.00 LBS
0.0 g / 0.0 N
|
Table 3: Vertical assembly (sliding) - behavior on slippery surfaces
MW 10x2 zestaw 10 szt. / N38
| Surface type | Friction coefficient / % | Max load (kg/lbs/g/N) |
|---|---|---|
| Raw steel |
µ = 0.3
30% of nominal force
|
0.38 kg / 0.84 LBS
381.0 g / 3.7 N
|
| Painted steel (standard) |
µ = 0.2
20% of nominal force
|
0.25 kg / 0.56 LBS
254.0 g / 2.5 N
|
| Oily/slippery steel |
µ = 0.1
10% of nominal force
|
0.13 kg / 0.28 LBS
127.0 g / 1.2 N
|
| Magnet with anti-slip rubber |
µ = 0.5
50% of nominal force
|
0.64 kg / 1.40 LBS
635.0 g / 6.2 N
|
Table 4: Material efficiency (saturation) - sheet metal selection
MW 10x2 zestaw 10 szt. / N38
| Steel thickness (mm) | % power | Real pull force (kg/lbs/g/N) |
|---|---|---|
| 0.5 mm |
|
0.13 kg / 0.28 LBS
127.0 g / 1.2 N
|
| 1 mm |
|
0.32 kg / 0.70 LBS
317.5 g / 3.1 N
|
| 2 mm |
|
0.64 kg / 1.40 LBS
635.0 g / 6.2 N
|
| 3 mm |
|
0.95 kg / 2.10 LBS
952.5 g / 9.3 N
|
| 5 mm |
|
1.27 kg / 2.80 LBS
1270.0 g / 12.5 N
|
| 10 mm |
|
1.27 kg / 2.80 LBS
1270.0 g / 12.5 N
|
| 11 mm |
|
1.27 kg / 2.80 LBS
1270.0 g / 12.5 N
|
| 12 mm |
|
1.27 kg / 2.80 LBS
1270.0 g / 12.5 N
|
Table 5: Thermal stability (material behavior) - power drop
MW 10x2 zestaw 10 szt. / N38
| Magnet temperature (°C) | Force change relative to 20°C | Remaining pull (kg/lbs/g/N) | Status |
|---|---|---|---|
| 20 °C | 0.0% |
1.27 kg / 2.80 LBS
1270.0 g / 12.5 N
|
Estimate |
| 40 °C | -4.4% |
1.21 kg / 2.68 LBS
1214.7 g / 11.9 N
|
Estimate |
| 60 °C | -8.6% |
1.16 kg / 2.56 LBS
1160.7 g / 11.4 N
|
Estimate |
| 80 °C | -12.8% |
1.11 kg / 2.44 LBS
1107.9 g / 10.9 N
|
Material limit |
| 100 °C | — | — | Out of range — no model |
Table 6: Two magnets (repulsion) - forces in the system
MW 10x2 zestaw 10 szt. / N38
| Gap (mm) | Attraction (kg/lbs) (N-S) | Shear Strength (kg/lbs/g/N) | Repulsion (kg/lbs) (N-N) |
|---|---|---|---|
| 0 mm |
2.56 kg / 5.65 LBS
3 867 Gs
|
0.38 kg / 0.85 LBS
384 g / 3.8 N
|
N/A |
| 1 mm |
2.25 kg / 4.96 LBS
4 312 Gs
|
0.34 kg / 0.74 LBS
338 g / 3.3 N
|
2.03 kg / 4.46 LBS
~0 Gs
|
| 2 mm |
1.89 kg / 4.16 LBS
3 948 Gs
|
0.28 kg / 0.62 LBS
283 g / 2.8 N
|
1.70 kg / 3.74 LBS
~0 Gs
|
| 3 mm |
1.52 kg / 3.36 LBS
3 548 Gs
|
0.23 kg / 0.50 LBS
229 g / 2.2 N
|
1.37 kg / 3.02 LBS
~0 Gs
|
| 5 mm |
0.92 kg / 2.02 LBS
2 750 Gs
|
0.14 kg / 0.30 LBS
137 g / 1.3 N
|
0.82 kg / 1.82 LBS
~0 Gs
|
| 10 mm |
0.21 kg / 0.47 LBS
1 322 Gs
|
0.03 kg / 0.07 LBS
32 g / 0.3 N
|
0.19 kg / 0.42 LBS
~0 Gs
|
| 20 mm |
0.02 kg / 0.03 LBS
355 Gs
|
0.00 kg / 0.01 LBS
2 g / 0.0 N
|
0.01 kg / 0.03 LBS
~0 Gs
|
| 50 mm |
0.00 kg / 0.00 LBS
33 Gs
|
0.00 kg / 0.00 LBS
0 g / 0.0 N
|
0.00 kg / 0.00 LBS
~0 Gs
|
| 60 mm |
0.00 kg / 0.00 LBS
20 Gs
|
0.00 kg / 0.00 LBS
0 g / 0.0 N
|
0.00 kg / 0.00 LBS
~0 Gs
|
| 70 mm |
0.00 kg / 0.00 LBS
13 Gs
|
0.00 kg / 0.00 LBS
0 g / 0.0 N
|
0.00 kg / 0.00 LBS
~0 Gs
|
| 80 mm |
0.00 kg / 0.00 LBS
9 Gs
|
0.00 kg / 0.00 LBS
0 g / 0.0 N
|
0.00 kg / 0.00 LBS
~0 Gs
|
| 90 mm |
0.00 kg / 0.00 LBS
6 Gs
|
0.00 kg / 0.00 LBS
0 g / 0.0 N
|
0.00 kg / 0.00 LBS
~0 Gs
|
| 100 mm |
0.00 kg / 0.00 LBS
5 Gs
|
0.00 kg / 0.00 LBS
0 g / 0.0 N
|
0.00 kg / 0.00 LBS
~0 Gs
|
Table 7: Axial field levels — not safety zones
MW 10x2 zestaw 10 szt. / N38
| Field level (Gs) | mT | Model distance (cm) |
|---|---|---|
| < 5 Gs | < 0.5 mT | 4.0 cm |
| < 10 Gs | < 1.0 mT | 3.5 cm |
| < 20 Gs | < 2.0 mT | 2.5 cm |
| < 40 Gs | < 4.0 mT | 2.0 cm |
| < 50 Gs | < 5.0 mT | 2.0 cm |
| < 400 Gs | < 40.0 mT | 1.0 cm |
| < 600 Gs | < 60.0 mT | 1.0 cm |
Table 8: Impact energy (kinetic energy) - warning
MW 10x2 zestaw 10 szt. / N38
| Start from (mm) | Speed (km/h) | Energy (J) | Predicted outcome |
|---|---|---|---|
| 10 mm |
7.91 km/h
(2.20 m/s)
|
0.03 J | |
| 30 mm |
7.94 km/h
(2.21 m/s)
|
0.03 J | |
| 50 mm |
7.94 km/h
(2.21 m/s)
|
0.03 J | |
| 100 mm |
7.94 km/h
(2.21 m/s)
|
0.03 J |
Table 9: Coating parameters (durability)
MW 10x2 zestaw 10 szt. / N38
| Technical parameter | Value / Description |
|---|---|
| Coating type | [NiCuNi] Nickel |
| Layer structure | Nickel - Copper - Nickel |
| Layer thickness | 10-20 µm |
| Salt spray test (SST) ? | 24 h |
| Recommended environment | Indoors only (dry) |
Table 10: Construction data (Pc)
MW 10x2 zestaw 10 szt. / N38
| Parameter | Value | SI Unit / Description |
|---|---|---|
| Magnetic Flux | 2 097 Mx | 21.0 µWb |
| Pc Coefficient | 0.29 | Low (Flat) |
Table 11: Underwater work (magnet fishing)
MW 10x2 zestaw 10 szt. / N38
| Environment | Effective steel pull | Effect |
|---|---|---|
| Air (land) | 1.27 kg | Standard |
| Water (riverbed) |
1.45 kg
(+0.18 kg buoyancy gain)
|
+14.5% |
1. Vertical hold
*Caution: On a vertical wall, the magnet holds just ~20% of its perpendicular strength.
2. Steel saturation
*Thin steel (e.g. 0.5mm PC case) drastically reduces the holding force.
3. Heat tolerance
N38: the maximum material working temperature is 80°C. Permitted conditions also depend on the shape and magnetic circuit.
4. Demagnetization curve and operating point (B-H)
chart generated for the permeance coefficient Pc (Permeance Coefficient) = 0.29
The chart above illustrates the magnetic characteristics of the material within the second quadrant of the hysteresis loop. The solid red line represents the demagnetization curve (material potential), while the dashed blue line is the load line based on the magnet's geometry. The Pc (Permeance Coefficient), also known as the load line slope, is a dimensionless value that describes the relationship between the magnet's shape and its magnetic stability. The intersection of these two lines (the black dot) is the operating point — it determines the actual magnetic flux density generated by the magnet in this specific configuration. A higher Pc value means the magnet is more 'slender' (tall relative to its area), resulting in a higher operating point and better resistance to irreversible demagnetization caused by external fields or temperature. A value of 0.42 is relatively low (typical for flat magnets), meaning the operating point is closer to the 'knee' of the curve — caution is advised when operating at temperatures near the maximum limit to avoid strength loss.
Elemental analysis
| iron (Fe) | 64% – 68% |
| neodymium (Nd) | 29% – 32% |
| boron (B) | 1.1% – 1.2% |
| dysprosium (Dy) | 0.5% – 2.0% |
| coating (Ni-Cu-Ni) | < 0.05% |
Environmental data
| recyclability (EoL) | 100% |
| recycled raw materials | ~10% (pre-cons) |
| carbon footprint | low / zredukowany |
| waste code (EWC) | 16 02 16 |
See more offers
Advantages as well as disadvantages of Nd2Fe14B magnets.
Strengths
- They retain magnetic properties for around ten years – the loss is just ~1% (based on simulations),
- They have excellent resistance to magnetism drop due to external fields,
- Thanks to the glossy finish, the coating of nickel, gold-plated, or silver-plated gives an aesthetic appearance,
- They show high magnetic induction at the operating surface, which affects their effectiveness,
- Due to their durability and thermal resistance, neodymium magnets are capable of operate (depending on the shape) even at high temperatures reaching 230°C or more...
- In view of the ability of precise shaping and customization to individualized needs, magnetic components can be manufactured in a wide range of shapes and sizes, which expands the range of possible applications,
- Key role in advanced technology sectors – they are used in data components, electromotive mechanisms, advanced medical instruments, and industrial machines.
- Thanks to concentrated force, small magnets offer high operating force, in miniature format,
Weaknesses
- Susceptibility to cracking is one of their disadvantages. Upon intense impact they can fracture. We advise keeping them in a special holder, which not only secures them against impacts but also raises their durability
- Do not exceed this material temperature limit: 80°C. Overheating may permanently weaken the magnet.
- They rust in a humid environment. For use outdoors we recommend using waterproof magnets e.g. in rubber, plastic
- We suggest cover - magnetic mechanism, due to difficulties in creating threads inside the magnet and complex shapes.
- Health risk resulting from small fragments of magnets can be dangerous, if swallowed, which is particularly important in the context of child health protection. Furthermore, tiny parts of these devices are able to complicate diagnosis medical after entering the body.
- High unit price – neodymium magnets have a higher price than other types of magnets (e.g. ferrite), which can limit application in large quantities
Pull force analysis
Optimal lifting capacity of a neodymium magnet – what contributes to it?
- using a plate made of mild steel, functioning as a circuit closing element
- whose thickness is min. 10 mm
- with an polished touching surface
- without the slightest insulating layer between the magnet and steel
- during pulling in a direction perpendicular to the mounting surface
- at temperature room level
Impact of factors on magnetic holding capacity in practice
- Clearance – existence of any layer (rust, dirt, gap) acts as an insulator, which lowers power rapidly (even by 50% at 0.5 mm).
- Pull-off angle – remember that the magnet has greatest strength perpendicularly. Under sliding down, the capacity drops significantly, often to levels of 20-30% of the maximum value.
- Substrate thickness – for full efficiency, the steel must be sufficiently thick. Thin sheet limits the lifting capacity (the magnet "punches through" it).
- Material type – ideal substrate is high-permeability steel. Cast iron may generate lower lifting capacity.
- Surface structure – the more even the plate, the better the adhesion and stronger the hold. Roughness acts like micro-gaps.
- Thermal environment – temperature increase causes a temporary drop of force. Check the maximum operating temperature for a given model.
Lifting capacity was determined with the use of a steel plate with a smooth surface of suitable thickness (min. 20 mm), under perpendicular detachment force, whereas under shearing force the lifting capacity is smaller. Additionally, even a small distance between the magnet’s surface and the plate decreases the lifting capacity.
Precautions when working with NdFeB magnets
Product not for children
These products are not intended for children. Accidental ingestion of multiple magnets may result in them connecting inside the digestive tract, which poses a direct threat to life and necessitates urgent medical intervention.
Magnetic media
Do not bring magnets near a wallet, computer, or TV. The magnetic field can permanently damage these devices and wipe information from cards.
Hand protection
Danger of trauma: The attraction force is so immense that it can cause hematomas, pinching, and even bone fractures. Use thick gloves.
Threat to navigation
A strong magnetic field disrupts the functioning of compasses in phones and GPS navigation. Maintain magnets near a smartphone to prevent damaging the sensors.
Conscious usage
Be careful. Neodymium magnets attract from a distance and connect with huge force, often faster than you can move away.
Warning for allergy sufferers
Studies show that the nickel plating (standard magnet coating) is a common allergen. If your skin reacts to metals, refrain from direct skin contact and choose versions in plastic housing.
Do not drill into magnets
Fire warning: Rare earth powder is explosive. Avoid machining magnets in home conditions as this risks ignition.
Danger to pacemakers
People with a ICD have to keep an safe separation from magnets. The magnetism can interfere with the operation of the implant.
Magnets are brittle
Watch out for shards. Magnets can explode upon violent connection, ejecting shards into the air. We recommend safety glasses.
Heat sensitivity
Do not exceed the maximum operating temperature stated in the specifications of the particular product. The limit depends on the material, geometry and operating arrangement; there is no single threshold for all neodymium magnets. Overheating can permanently weaken a magnet.