SM 32x200 [2xM8] / N42 - magnetic separator
magnetic separator
Catalog no 130298
GTIN/EAN: 5906301812913
- Diameter Ø
- 32 mm [±1 mm]
- Height
- 200 mm [±1 mm]
- Weight
- 1070 g
- Magnetic Flux
- ~ 8 000 Gauss [±5%]
How we measure these parameters — certificates and measurements
590.00 zł net / pcs
725.70 zł with VAT (23% VAT) / pcs
bulk discounts:
Need more?Frequently asked questions
Which rod should I choose for fine contamination?
Which rod pitch should I choose?
Why does efficiency drop after a few weeks of operation?
Call us now
+48 888 99 98 98
alternatively let us know using
contact form
the contact section.
Specifications and structure of a neodymium magnet can be estimated using our
power calculator.
Order by 14:00 and we’ll ship today!
Technical - SM 32x200 [2xM8] / N42 - magnetic separator
Specification / characteristics - SM 32x200 [2xM8] / N42 - magnetic separator
| properties | values |
|---|---|
| Cat. no. | 130298 |
| GTIN/EAN | 5906301812913 |
| Production/Distribution | Dhit sp. z o.o. |
| Country of origin | Poland / China / Germany |
| Customs code | 85059029 |
| Diameter Ø | 32 mm [±1 mm] |
| Height | 200 mm [±1 mm] |
| Weight | 1070 g |
| Material Type | Stainless steel AISI 304 / A2 |
| Magnetic Flux | ~ 8 000 Gauss [±5%] |
| Size/Mount Quantity | 2xM8 |
| Polarity | circumferential - 7 poles |
| Casing Tube Thickness | 1 mm |
| Manufacturing Tolerance | ±1 mm |
Magnetic properties of material N42
| properties | values | units |
|---|---|---|
| Remanence Br ? | 12.9-13.2 | kGs |
| Remanence Br ? | 1290-1320 | mT |
| Coercivity bHc ? | 10.8-12.0 | kOe |
| Coercivity bHc ? | 860-955 | kA/m |
| Intrinsic coercivity iHc | ≥ 12 | kOe |
| Intrinsic coercivity iHc | ≥ 955 | kA/m |
| Energy product BHmax ? | 40-42 | BH max MGOe |
| Energy product BHmax ? | 318-334 | BH max KJ/m |
| Maximum working temperature ? | ≤ 80 | °C |
Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C
| properties | values | units |
|---|---|---|
| Vickers hardness | ≥550 | Hv |
| Density | ≥7.4 | g/cm3 |
| Curie Temperature TC | 310 | °C |
| Curie Temperature TF | 590 | °F |
| Specific resistance | 150 | μΩ⋅cm |
| Bending strength | 250 | MPa |
| Compressive strength | 1000~1100 | MPa |
| Thermal expansion parallel (∥) to orientation (M) | (3-4) x 10-6 | °C-1 |
| Thermal expansion perpendicular (⊥) to orientation (M) | -(1-3) x 10-6 | °C-1 |
| Young's modulus | 1.7 x 104 | kg/mm² |
Table 1: Rod construction
SM 32x200 [2xM8] / N42
| Parameter | Value | Description / Unit |
|---|---|---|
| Diameter (Ø) | 32 | mm |
| Total length | 200 | mm (L) |
| Active length | 164 | mm |
| Section count | 7 | modules |
| Dead zone | 36 | mm (2x 18mm starter) |
| Weight (est.) | ~1222 | g |
| Active area | 165 | cm² (Area) |
| Housing material | AISI 304 | 1.4301 (Inox) |
| Surface finish | Ra < 0.8 µm | Polished |
| Temp. class | 80°C | Standard (N) |
| Force loss (at max °C) | -12.8% | Reversible loss (physics) |
| Force (calculated) | 26.2 | kg (theor.) |
| Induction (surface) | ~8 000 | Gauss (Max) |
Chart 2: Field profile (7 sections)
Chart 3: Temperature performance
Chemical composition
| iron (Fe) | 64% – 68% |
| neodymium (Nd) | 29% – 32% |
| boron (B) | 1.1% – 1.2% |
| dysprosium (Dy) | 0.5% – 2.0% |
| coating (Ni-Cu-Ni) | < 0.05% |
Ecology and recycling (GPSR)
| recyclability (EoL) | 100% |
| recycled raw materials | ~10% (pre-cons) |
| carbon footprint | low / zredukowany |
| waste code (EWC) | 16 02 16 |
Other products
Pros and cons of Nd2Fe14B magnets.
Pros
- They do not lose power, even after around ten years – the reduction in lifting capacity is only ~1% (based on measurements),
- They are extremely resistant to demagnetization induced by presence of other magnetic fields,
- The use of an aesthetic layer of noble metals (nickel, gold, silver) causes the element to have aesthetics,
- Magnets are characterized by maximum magnetic induction on the surface,
- Neodymium magnets are characterized by extremely high magnetic induction on the magnet surface and can work (depending on the shape) even at a temperature of 230°C or more...
- Thanks to versatility in forming and the ability to modify to unusual requirements,
- Key role in future technologies – they are utilized in hard drives, electric motors, medical devices, and technologically advanced constructions.
- Compactness – despite small sizes they offer powerful magnetic field, making them ideal for precision applications
Limitations
- To avoid cracks under impact, we recommend using special steel holders. Such a solution protects the magnet and simultaneously increases its durability.
- When exposed to high temperature, neodymium magnets suffer a drop in power. Often, when the temperature exceeds 80°C, their strength decreases (depending on the size and shape of the magnet). For those who need magnets for extreme conditions, we offer [AH] versions withstanding up to 230°C
- They rust in a humid environment. For use outdoors we advise using waterproof magnets e.g. in rubber, plastic
- We suggest casing - magnetic mount, due to difficulties in creating nuts inside the magnet and complicated forms.
- Possible danger resulting from small fragments of magnets pose a threat, in case of ingestion, which becomes key in the context of child health protection. Additionally, small elements of these devices can be problematic in diagnostics medical when they are in the body.
- With mass production the cost of neodymium magnets is economically unviable,
Pull force analysis
Maximum magnetic pulling force – what contributes to it?
- with the application of a sheet made of special test steel, ensuring maximum field concentration
- possessing a thickness of at least 10 mm to avoid saturation
- with an ideally smooth contact surface
- under conditions of ideal adhesion (metal-to-metal)
- during pulling in a direction vertical to the plane
- at room temperature
Lifting capacity in practice – influencing factors
- Clearance – the presence of foreign body (paint, tape, gap) interrupts the magnetic circuit, which lowers power steeply (even by 50% at 0.5 mm).
- Loading method – catalog parameter refers to pulling vertically. When applying parallel force, the magnet exhibits much less (often approx. 20-30% of nominal force).
- Plate thickness – insufficiently thick plate does not accept the full field, causing part of the power to be wasted into the air.
- Steel type – low-carbon steel attracts best. Higher carbon content reduce magnetic permeability and lifting capacity.
- Surface structure – the more even the surface, the larger the contact zone and stronger the hold. Unevenness acts like micro-gaps.
- Thermal factor – high temperature weakens pulling force. Too high temperature can permanently demagnetize the magnet.
Lifting capacity was measured using a smooth steel plate of optimal thickness (min. 20 mm), under vertically applied force, whereas under parallel forces the load capacity is reduced by as much as 5 times. Additionally, even a minimal clearance between the magnet and the plate decreases the load capacity.
H&S for magnets
Health Danger
Individuals with a heart stimulator should maintain an large gap from magnets. The magnetic field can interfere with the operation of the implant.
Nickel coating and allergies
Medical facts indicate that nickel (standard magnet coating) is a common allergen. For allergy sufferers, refrain from direct skin contact and choose versions in plastic housing.
Dust is flammable
Dust generated during cutting of magnets is flammable. Do not drill into magnets without proper cooling and knowledge.
Beware of splinters
Despite the nickel coating, neodymium is brittle and cannot withstand shocks. Avoid impacts, as the magnet may crumble into hazardous fragments.
Keep away from computers
Powerful magnetic fields can corrupt files on credit cards, HDDs, and other magnetic media. Maintain a gap of min. 10 cm.
Bone fractures
Risk of injury: The attraction force is so immense that it can result in hematomas, crushing, and even bone fractures. Protective gloves are recommended.
Demagnetization risk
Monitor thermal conditions. Exposing the magnet to high heat will permanently weaken its magnetic structure and strength.
Compass and GPS
A strong magnetic field interferes with the operation of magnetometers in smartphones and GPS navigation. Maintain magnets close to a device to avoid breaking the sensors.
Handling guide
Handle magnets with awareness. Their immense force can surprise even experienced users. Be vigilant and do not underestimate their force.
Danger to the youngest
Only for adults. Tiny parts pose a choking risk, causing intestinal necrosis. Keep away from children and animals.