SM 28x240 [2xM8] / N52 - magnetic separator
magnetic separator
Catalog no 130566
GTIN/EAN: 5906301815587
- Diameter Ø
- 28 mm [±1 mm]
- Height
- 240 mm [±1 mm]
- Weight
- 1154.04 g
- Magnetic Flux
- ~ 8 500 Gauss [±5%]
How we measure these parameters — certificates and measurements
626.00 zł net / pcs
769.98 zł with VAT (23% VAT) / pcs
bulk discounts:
Need more?Frequently asked questions
How do I choose a separator for fine contamination and check availability?
Where can I order a separator for a production line, and what should I check?
How can I verify a separator's declared magnetic parameters before purchase?
Can a magnetic beam withstand continuous work on a production line?
What roller design is suitable for a dusty environment?
How do I choose the size of a hand-held separator?
What is a hand-held separator for, and how is it different from a built-in rod?
Which separator type suits a small production plant?
Call us now
+48 888 99 98 98
alternatively let us know using
contact form
the contact section.
Specifications and structure of a neodymium magnet can be estimated using our
power calculator.
Order by 14:00 and we’ll ship today!
Technical - SM 28x240 [2xM8] / N52 - magnetic separator
Specification / characteristics - SM 28x240 [2xM8] / N52 - magnetic separator
| properties | values |
|---|---|
| Cat. no. | 130566 |
| GTIN/EAN | 5906301815587 |
| Distributor | Dhit sp. z o.o. |
| Country of origin | Poland / China / Germany |
| Customs code | 85059029 |
| Diameter Ø | 28 mm [±1 mm] |
| Height | 240 mm [±1 mm] |
| Weight | 1154.04 g |
| Material Type | Stainless steel AISI 304 / A2 |
| Magnetic Flux | ~ 8 500 Gauss [±5%] |
| Size/Mount Quantity | M8x2 |
| Polarity | circumferential - 8 poles |
| Casing Tube Thickness | 1 mm |
| Manufacturing Tolerance | ±1 mm |
Magnetic properties of material N52
| properties | values | units |
|---|---|---|
| Remanence Br ? | 14.2-14.7 | kGs |
| Remanence Br ? | 1420-1470 | mT |
| Coercivity bHc ? | 10.8-12.5 | kOe |
| Coercivity bHc ? | 860-995 | kA/m |
| Intrinsic coercivity iHc | ≥ 12 | kOe |
| Intrinsic coercivity iHc | ≥ 955 | kA/m |
| Energy product BHmax ? | 48-53 | BH max MGOe |
| Energy product BHmax ? | 380-422 | BH max KJ/m |
| Maximum working temperature ? | ≤ 60 | °C |
Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C
| properties | values | units |
|---|---|---|
| Vickers hardness | ≥550 | Hv |
| Density | ≥7.4 | g/cm3 |
| Curie Temperature TC | 310 | °C |
| Curie Temperature TF | 590 | °F |
| Specific resistance | 150 | μΩ⋅cm |
| Bending strength | 250 | MPa |
| Compressive strength | 1000~1100 | MPa |
| Thermal expansion parallel (∥) to orientation (M) | (3-4) x 10-6 | °C-1 |
| Thermal expansion perpendicular (⊥) to orientation (M) | -(1-3) x 10-6 | °C-1 |
| Young's modulus | 1.7 x 104 | kg/mm² |
Table 1: Rod construction
SM 28x240 [2xM8] / N52
| Parameter | Value | Description / Unit |
|---|---|---|
| Diameter (Ø) | 28 | mm |
| Total length | 240 | mm (L) |
| Active length | 204 | mm |
| Section count | 8 | modules |
| Dead zone | 36 | mm (2x 18mm starter) |
| Weight (est.) | ~1123 | g |
| Active area | 179 | cm² (Area) |
| Housing material | AISI 304 | 1.4301 (Inox) |
| Surface finish | Ra < 0.8 µm | Polished |
| Temp. class | 60°C | N52 |
| Force loss (at max °C) | -8.6% | Reversible loss (physics) |
| Force (calculated) | 22.7 | kg (theor.) |
| Induction (surface) | ~8 500 | Gauss (Max) |
Chart 2: Field profile (8 sections)
Chart 3: Temperature performance
Material specification
| iron (Fe) | 64% – 68% |
| neodymium (Nd) | 29% – 32% |
| boron (B) | 1.1% – 1.2% |
| dysprosium (Dy) | 0.5% – 2.0% |
| coating (Ni-Cu-Ni) | < 0.05% |
Ecology and recycling (GPSR)
| recyclability (EoL) | 100% |
| recycled raw materials | ~10% (pre-cons) |
| carbon footprint | low / zredukowany |
| waste code (EWC) | 16 02 16 |
Other offers
Pros and cons of neodymium magnets.
Benefits
- They do not lose power, even after approximately ten years – the reduction in lifting capacity is only ~1% (theoretically),
- Magnets perfectly resist against loss of magnetization caused by external fields,
- A magnet with a shiny nickel surface looks better,
- They are known for high magnetic induction at the operating surface, which affects their effectiveness,
- Thanks to resistance to high temperature, they can operate (depending on the shape) even at temperatures up to 230°C and higher...
- In view of the ability of accurate shaping and adaptation to unique requirements, neodymium magnets can be created in a broad palette of geometric configurations, which increases their versatility,
- Key role in high-tech industry – they find application in HDD drives, drive modules, medical equipment, as well as industrial machines.
- Compactness – despite small sizes they offer powerful magnetic field, making them ideal for precision applications
Limitations
- To avoid cracks upon strong impacts, we recommend using special steel holders. Such a solution protects the magnet and simultaneously improves its durability.
- Do not exceed this material temperature limit: 60°C. Overheating may permanently weaken the magnet.
- Magnets exposed to a humid environment can corrode. Therefore during using outdoors, we advise using waterproof magnets made of rubber, plastic or other material resistant to moisture
- We suggest cover - magnetic holder, due to difficulties in producing threads inside the magnet and complicated shapes.
- Possible danger related to microscopic parts of magnets pose a threat, if swallowed, which is particularly important in the context of child health protection. Additionally, tiny parts of these devices are able to complicate diagnosis medical in case of swallowing.
- High unit price – neodymium magnets have a higher price than other types of magnets (e.g. ferrite), which increases costs of application in large quantities
Pull force analysis
Maximum holding power of the magnet – what contributes to it?
- with the contact of a sheet made of special test steel, guaranteeing maximum field concentration
- possessing a massiveness of minimum 10 mm to ensure full flux closure
- characterized by even structure
- without any insulating layer between the magnet and steel
- for force acting at a right angle (pull-off, not shear)
- at temperature approx. 20 degrees Celsius
Lifting capacity in practice – influencing factors
- Distance (betwixt the magnet and the metal), since even a very small distance (e.g. 0.5 mm) leads to a reduction in force by up to 50% (this also applies to varnish, corrosion or debris).
- Loading method – declared lifting capacity refers to pulling vertically. When slipping, the magnet exhibits significantly lower power (typically approx. 20-30% of nominal force).
- Metal thickness – the thinner the sheet, the weaker the hold. Magnetic flux passes through the material instead of generating force.
- Metal type – not every steel reacts the same. High carbon content weaken the attraction effect.
- Base smoothness – the more even the surface, the better the adhesion and higher the lifting capacity. Unevenness acts like micro-gaps.
- Temperature – heating the magnet causes a temporary drop of force. It is worth remembering the maximum operating temperature for a given model.
Lifting capacity was assessed using a polished steel plate of suitable thickness (min. 20 mm), under vertically applied force, whereas under attempts to slide the magnet the holding force is lower. Moreover, even a small distance between the magnet and the plate reduces the load capacity.
H&S for magnets
Phone sensors
GPS units and mobile phones are highly susceptible to magnetism. Direct contact with a powerful NdFeB magnet can permanently damage the sensors in your phone.
Fire warning
Fire hazard: Rare earth powder is highly flammable. Do not process magnets without safety gear as this may cause fire.
Serious injuries
Mind your fingers. Two large magnets will join instantly with a force of massive weight, crushing anything in their path. Be careful!
Skin irritation risks
Medical facts indicate that nickel (the usual finish) is a strong allergen. If your skin reacts to metals, prevent touching magnets with bare hands and select encased magnets.
Choking Hazard
Always store magnets out of reach of children. Risk of swallowing is high, and the effects of magnets clamping inside the body are tragic.
Protect data
Data protection: Neodymium magnets can ruin data carriers and delicate electronics (pacemakers, medical aids, mechanical watches).
Immense force
Handle magnets consciously. Their powerful strength can surprise even professionals. Be vigilant and do not underestimate their force.
Danger to pacemakers
Individuals with a pacemaker should maintain an absolute distance from magnets. The magnetic field can interfere with the functioning of the life-saving device.
Magnet fragility
Watch out for shards. Magnets can explode upon uncontrolled impact, ejecting shards into the air. Eye protection is mandatory.
Maximum temperature
Do not exceed the maximum operating temperature stated in the specifications of the particular product. The limit depends on the material, geometry and operating arrangement; there is no single threshold for all neodymium magnets. Overheating can permanently weaken a magnet.