Product on order Ships in 3-5 days CO2 GPSR PPWR REACH

SM 28x240 [2xM8] / N52 - magnetic separator

magnetic separator

Catalog no 130566

GTIN/EAN: 5906301815587

Diameter Ø
28 mm [±1 mm]
Height
240 mm [±1 mm]
Weight
1154.04 g
Magnetic Flux
~ 8 500 Gauss [±5%]

How we measure these parameters — certificates and measurements

626.00 zł net / pcs

769.98 zł with VAT (23% VAT) / pcs

price for transport

bulk discounts:

Need more?

Quantity
Net
Gross
price from 1 pcs
626.00 zł
769.98 zł
price from 5 pcs
594.70 zł
731.48 zł
price from 10 pcs
563.40 zł
692.98 zł

Frequently asked questions

How do I choose a separator for fine contamination and check availability?
Start with the size and type of contaminant, the material flow and the working surface. Compare the magnetic-field data and dimensions stated on the selected product card, and check current availability there.
Where can I order a separator for a production line, and what should I check?
Match the device to the installation dimensions, material flow, cleaning method and housing requirements. A drawing or the dimensions of the transfer point help determine whether a catalogue model fits or a custom version is needed.
How can I verify a separator's declared magnetic parameters before purchase?
Ask for the measured value, the point of measurement and the method or instrument used. A field-strength figure without its measurement conditions cannot be compared reliably with another product.
Can a magnetic beam withstand continuous work on a production line?
Check the construction, mounting and cleaning procedure for the chosen beam. Captured metal must be removed regularly; a layer of particles can reduce effective separation even when the magnets themselves are sound.
What roller design is suitable for a dusty environment?
Check the bearing protection, surface finish and cleaning access of the selected model. Dust accumulation and abrasion depend on the installation, so specify the actual process conditions before choosing a version.
How do I choose the size of a hand-held separator?
Match the rod diameter and length to the container and material depth, and consider the tool's weight for repeated manual work. Use the dimensions and magnetic data on the current product card.
What is a hand-held separator for, and how is it different from a built-in rod?
A built-in rod stays in the process line. A hand-held separator is moved through a material sample or container and then cleaned. It is useful for spot checks or occasional cleanup when permanent installation is not required.
Which separator type suits a small production plant?
Choose by the point in the process: a grate at a hopper, a beam over a conveyor, a built-in rod in a chute or pipe, or a hand-held tool for spot checks. A magnetic gripper handles steel parts rather than separating contamination.
Want to talk magnets?

Call us now +48 888 99 98 98 alternatively let us know using contact form the contact section.
Specifications and structure of a neodymium magnet can be estimated using our power calculator.

Order by 14:00 and we’ll ship today!

Technical - SM 28x240 [2xM8] / N52 - magnetic separator

Specification / characteristics - SM 28x240 [2xM8] / N52 - magnetic separator

properties
properties values
Cat. no. 130566
GTIN/EAN 5906301815587
Distributor Dhit sp. z o.o.
Country of origin Poland / China / Germany
Customs code 85059029
Diameter Ø 28 mm [±1 mm]
Height 240 mm [±1 mm]
Weight 1154.04 g
Material Type Stainless steel AISI 304 / A2
Magnetic Flux ~ 8 500 Gauss [±5%]
Size/Mount Quantity M8x2
Polarity circumferential - 8 poles
Casing Tube Thickness 1 mm
Manufacturing Tolerance ±1 mm

Magnetic properties of material N52

Specification / characteristics SM 28x240 [2xM8] / N52 - magnetic separator
properties values units
Remanence Br ? 14.2-14.7 kGs
Remanence Br ? 1420-1470 mT
Coercivity bHc ? 10.8-12.5 kOe
Coercivity bHc ? 860-995 kA/m
Intrinsic coercivity iHc ≥ 12 kOe
Intrinsic coercivity iHc ≥ 955 kA/m
Energy product BHmax ? 48-53 BH max MGOe
Energy product BHmax ? 380-422 BH max KJ/m
Maximum working temperature ? ≤ 60 °C

Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C

Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C
properties values units
Vickers hardness ≥550 Hv
Density ≥7.4 g/cm3
Curie Temperature TC 310 °C
Curie Temperature TF 590 °F
Specific resistance 150 μΩ⋅cm
Bending strength 250 MPa
Compressive strength 1000~1100 MPa
Thermal expansion parallel (∥) to orientation (M) (3-4) x 10-6 °C-1
Thermal expansion perpendicular (⊥) to orientation (M) -(1-3) x 10-6 °C-1
Young's modulus 1.7 x 104 kg/mm²

Table 1: Rod construction
SM 28x240 [2xM8] / N52

Parameter Value Description / Unit
Diameter (Ø) 28 mm
Total length 240 mm (L)
Active length 204 mm
Section count 8 modules
Dead zone 36 mm (2x 18mm starter)
Weight (est.) ~1123 g
Active area 179 cm² (Area)
Housing material AISI 304 1.4301 (Inox)
Surface finish Ra < 0.8 µm Polished
Temp. class 60°C N52
Force loss (at max °C) -8.6% Reversible loss (physics)
Force (calculated) 22.7 kg (theor.)
Induction (surface) ~8 500 Gauss (Max)

Chart 2: Field profile (8 sections)

Chart 3: Temperature performance

Engineering data and GPSR

Material specification

iron (Fe) 64% – 68%
neodymium (Nd) 29% – 32%
boron (B) 1.1% – 1.2%
dysprosium (Dy) 0.5% – 2.0%
coating (Ni-Cu-Ni) < 0.05%

Ecology and recycling (GPSR)

recyclability (EoL) 100%
recycled raw materials ~10% (pre-cons)
carbon footprint low / zredukowany
waste code (EWC) 16 02 16
Safety card (GPSR)
responsible entity
Dhit sp. z o.o.
ul. Kościuszki 6A, 05-850 Ożarów Mazowiecki
tel: +48 22 499 98 98 | e-mail: bok@dhit.pl
batch number/type
id: 130566-2026
Magnet Unit Converter

Magnet pull force


Magnetic Field

Other offers

This product serves to effectively catch ferromagnetic contaminants from bulk and liquid products. It is mounted in chutes, hoppers, and pipelines to protect production machines from failure. High magnetic induction on the surface allows catching the finest iron particles.
The outer layer is hygienic acid-resistant steel, approved for food contact. Inside there is a stack of strong neodymium magnets arranged in a special configuration (magnetic circuit). Thanks to this, the rod is durable, hygienic, and easy to keep clean.
Metal contaminants are strongly attracted, so removing them with a bare hand or glove can be difficult. We recommend sticking packing tape to the cluster of filings and tearing it off together with the contaminants. For easier operation, it is worth considering ordering a rod in a version with a cleaning sleeve.
The Gauss value tells us how effectively and deeply the magnet will catch contaminants. The economical version (8kGs) handles large pieces of metal perfectly. For the food and precision industry, we recommend the highest induction parameters.
We can produce a rod of non-standard length with any mounting termination. We offer various tip options: threaded holes (e.g., M8, M10), protruding screws, flat pivots, mills, or handles. We ensure fast realization of special orders and technical advice.

Pros and cons of neodymium magnets.

Benefits

Besides their immense strength, neodymium magnets offer the following advantages:
  • They do not lose power, even after approximately ten years – the reduction in lifting capacity is only ~1% (theoretically),
  • Magnets perfectly resist against loss of magnetization caused by external fields,
  • A magnet with a shiny nickel surface looks better,
  • They are known for high magnetic induction at the operating surface, which affects their effectiveness,
  • Thanks to resistance to high temperature, they can operate (depending on the shape) even at temperatures up to 230°C and higher...
  • In view of the ability of accurate shaping and adaptation to unique requirements, neodymium magnets can be created in a broad palette of geometric configurations, which increases their versatility,
  • Key role in high-tech industry – they find application in HDD drives, drive modules, medical equipment, as well as industrial machines.
  • Compactness – despite small sizes they offer powerful magnetic field, making them ideal for precision applications

Limitations

Problematic aspects of neodymium magnets and proposals for their use:
  • To avoid cracks upon strong impacts, we recommend using special steel holders. Such a solution protects the magnet and simultaneously improves its durability.
  • Do not exceed this material temperature limit: 60°C. Overheating may permanently weaken the magnet.
  • Magnets exposed to a humid environment can corrode. Therefore during using outdoors, we advise using waterproof magnets made of rubber, plastic or other material resistant to moisture
  • We suggest cover - magnetic holder, due to difficulties in producing threads inside the magnet and complicated shapes.
  • Possible danger related to microscopic parts of magnets pose a threat, if swallowed, which is particularly important in the context of child health protection. Additionally, tiny parts of these devices are able to complicate diagnosis medical in case of swallowing.
  • High unit price – neodymium magnets have a higher price than other types of magnets (e.g. ferrite), which increases costs of application in large quantities

Pull force analysis

Maximum holding power of the magnet – what contributes to it?

Information about lifting capacity was determined for the most favorable conditions, taking into account:
  • with the contact of a sheet made of special test steel, guaranteeing maximum field concentration
  • possessing a massiveness of minimum 10 mm to ensure full flux closure
  • characterized by even structure
  • without any insulating layer between the magnet and steel
  • for force acting at a right angle (pull-off, not shear)
  • at temperature approx. 20 degrees Celsius

Lifting capacity in practice – influencing factors

Effective lifting capacity impacted by working environment parameters, mainly (from priority):
  • Distance (betwixt the magnet and the metal), since even a very small distance (e.g. 0.5 mm) leads to a reduction in force by up to 50% (this also applies to varnish, corrosion or debris).
  • Loading method – declared lifting capacity refers to pulling vertically. When slipping, the magnet exhibits significantly lower power (typically approx. 20-30% of nominal force).
  • Metal thickness – the thinner the sheet, the weaker the hold. Magnetic flux passes through the material instead of generating force.
  • Metal type – not every steel reacts the same. High carbon content weaken the attraction effect.
  • Base smoothness – the more even the surface, the better the adhesion and higher the lifting capacity. Unevenness acts like micro-gaps.
  • Temperature – heating the magnet causes a temporary drop of force. It is worth remembering the maximum operating temperature for a given model.

Lifting capacity was assessed using a polished steel plate of suitable thickness (min. 20 mm), under vertically applied force, whereas under attempts to slide the magnet the holding force is lower. Moreover, even a small distance between the magnet and the plate reduces the load capacity.

H&S for magnets
Phone sensors

GPS units and mobile phones are highly susceptible to magnetism. Direct contact with a powerful NdFeB magnet can permanently damage the sensors in your phone.

Fire warning

Fire hazard: Rare earth powder is highly flammable. Do not process magnets without safety gear as this may cause fire.

Serious injuries

Mind your fingers. Two large magnets will join instantly with a force of massive weight, crushing anything in their path. Be careful!

Skin irritation risks

Medical facts indicate that nickel (the usual finish) is a strong allergen. If your skin reacts to metals, prevent touching magnets with bare hands and select encased magnets.

Choking Hazard

Always store magnets out of reach of children. Risk of swallowing is high, and the effects of magnets clamping inside the body are tragic.

Protect data

Data protection: Neodymium magnets can ruin data carriers and delicate electronics (pacemakers, medical aids, mechanical watches).

Immense force

Handle magnets consciously. Their powerful strength can surprise even professionals. Be vigilant and do not underestimate their force.

Danger to pacemakers

Individuals with a pacemaker should maintain an absolute distance from magnets. The magnetic field can interfere with the functioning of the life-saving device.

Magnet fragility

Watch out for shards. Magnets can explode upon uncontrolled impact, ejecting shards into the air. Eye protection is mandatory.

Maximum temperature

Do not exceed the maximum operating temperature stated in the specifications of the particular product. The limit depends on the material, geometry and operating arrangement; there is no single threshold for all neodymium magnets. Overheating can permanently weaken a magnet.

Security! Details about hazards in the article: Magnet Safety Guide.