UI 45x13x5 [M301] zestaw 10 szt. / N38 - badge holder
badge holder
Catalog no 150556
GTIN/EAN: 5906301815488
- length
- 45 mm [±1 mm]
- Width
- 13 mm [±1 mm]
- Height
- 5 mm [±1 mm]
- Weight
- 1.4 g
How we measure these parameters — certificates and measurements
18.69 zł net / pcs
22.99 zł with VAT (23% VAT) / pcs
bulk discounts:
Need more?Frequently asked questions
What badge size fits these holders - will a standard 86x54 mm card work?
We already have lanyard or pin badges. Can they be converted to magnetic ones?
What should a staff badge show, and does it have to carry a surname?
Can the badge be swapped, for example on a change of role or for a conference?
Will the badge rotate, and is it readable from a distance at a counter or reception?
Pacemaker, hearing aid, contactless card - what about safety when wearing the badge?
We are ordering badges for a whole team. How many holders to count and what to order with them?
Call us now
+48 888 99 98 98
alternatively let us know using
contact form
the contact section.
Specifications and structure of a neodymium magnet can be estimated using our
power calculator.
Order by 14:00 and we’ll ship today!
Physical properties - UI 45x13x5 [M301] zestaw 10 szt. / N38 - badge holder
Specification / characteristics - UI 45x13x5 [M301] zestaw 10 szt. / N38 - badge holder
| properties | values |
|---|---|
| Cat. no. | 150556 |
| GTIN/EAN | 5906301815488 |
| Distributor | Dhit sp. z o.o. |
| Country of origin | Poland / China / Germany |
| Customs code | 85059029 |
| length | 45 mm [±1 mm] |
| Width | 13 mm [±1 mm] |
| Height | 5 mm [±1 mm] |
| Weight | 1.4 g |
| Load capacity ~ ? | 1.10 kg / 10.79 N |
| Manufacturing Tolerance | ±1 mm |
Magnetic properties of material N38
| properties | values | units |
|---|---|---|
| Remanence Br ? | 12.2-12.6 | kGs |
| Remanence Br ? | 1220-1260 | mT |
| Coercivity bHc ? | 10.8-11.5 | kOe |
| Coercivity bHc ? | 860-915 | kA/m |
| Intrinsic coercivity iHc | ≥ 12 | kOe |
| Intrinsic coercivity iHc | ≥ 955 | kA/m |
| Energy product BHmax ? | 36-38 | BH max MGOe |
| Energy product BHmax ? | 287-303 | BH max KJ/m |
| Maximum working temperature ? | ≤ 80 | °C |
Physical properties of sintered neodymium magnets Nd2Fe14B at 20°C
| properties | values | units |
|---|---|---|
| Vickers hardness | ≥550 | Hv |
| Density | ≥7.4 | g/cm3 |
| Curie Temperature TC | 310 | °C |
| Curie Temperature TF | 590 | °F |
| Specific resistance | 150 | μΩ⋅cm |
| Bending strength | 250 | MPa |
| Compressive strength | 1000~1100 | MPa |
| Thermal expansion parallel (∥) to orientation (M) | (3-4) x 10-6 | °C-1 |
| Thermal expansion perpendicular (⊥) to orientation (M) | -(1-3) x 10-6 | °C-1 |
| Young's modulus | 1.7 x 104 | kg/mm² |
Material specification
| iron (Fe) | 64% – 68% |
| neodymium (Nd) | 29% – 32% |
| boron (B) | 1.1% – 1.2% |
| dysprosium (Dy) | 0.5% – 2.0% |
| coating (Ni-Cu-Ni) | < 0.05% |
Environmental data
| recyclability (EoL) | 100% |
| recycled raw materials | ~10% (pre-cons) |
| carbon footprint | low / zredukowany |
| waste code (EWC) | 16 02 16 |
Check out also products
Pros as well as cons of Nd2Fe14B magnets.
Pros
- They retain full power for nearly ten years – the loss is just ~1% (in theory),
- Magnets very well protect themselves against loss of magnetization caused by external fields,
- By using a reflective coating of nickel, the element presents an proper look,
- They show high magnetic induction at the operating surface, which increases their power,
- Thanks to resistance to high temperature, they can operate (depending on the shape) even at temperatures up to 230°C and higher...
- Thanks to freedom in constructing and the capacity to modify to specific needs,
- Wide application in modern industrial fields – they find application in data components, electric drive systems, diagnostic systems, also industrial machines.
- Relatively small size with high pulling force – neodymium magnets offer strong magnetic field in tiny dimensions, which makes them useful in small systems
Cons
- Brittleness is one of their disadvantages. Upon intense impact they can break. We advise keeping them in a strong case, which not only protects them against impacts but also increases their durability
- Do not exceed this material temperature limit: 80°C. Overheating may permanently weaken the magnet.
- When exposed to humidity, magnets usually rust. To use them in conditions outside, it is recommended to use protective magnets, such as those in rubber or plastics, which secure oxidation as well as corrosion.
- Limited ability of making threads in the magnet and complicated shapes - recommended is a housing - mounting mechanism.
- Possible danger to health – tiny shards of magnets can be dangerous, when accidentally swallowed, which gains importance in the context of child safety. Additionally, small elements of these products can complicate diagnosis medical when they are in the body.
- Higher cost of purchase is a significant factor to consider compared to ceramic magnets, especially in budget applications
Holding force characteristics
Maximum lifting capacity of the magnet – what contributes to it?
- using a plate made of high-permeability steel, functioning as a ideal flux conductor
- with a cross-section of at least 10 mm
- with an polished touching surface
- without any air gap between the magnet and steel
- during detachment in a direction perpendicular to the mounting surface
- in temp. approx. 20°C
Key elements affecting lifting force
- Clearance – existence of any layer (paint, tape, air) acts as an insulator, which lowers power steeply (even by 50% at 0.5 mm).
- Force direction – remember that the magnet has greatest strength perpendicularly. Under sliding down, the capacity drops significantly, often to levels of 20-30% of the nominal value.
- Substrate thickness – to utilize 100% power, the steel must be sufficiently thick. Paper-thin metal restricts the lifting capacity (the magnet "punches through" it).
- Chemical composition of the base – mild steel gives the best results. Higher carbon content lower magnetic permeability and lifting capacity.
- Smoothness – full contact is obtained only on polished steel. Any scratches and bumps create air cushions, weakening the magnet.
- Temperature – temperature increase causes a temporary drop of induction. It is worth remembering the thermal limit for a given model.
Lifting capacity was assessed with the use of a smooth steel plate of optimal thickness (min. 20 mm), under perpendicular detachment force, however under parallel forces the load capacity is reduced by as much as 5 times. In addition, even a minimal clearance between the magnet’s surface and the plate reduces the holding force.
Safety rules for work with neodymium magnets
Thermal limits
Do not exceed the maximum operating temperature stated in the specifications of the particular product. The limit depends on the material, geometry and operating arrangement; there is no single threshold for all neodymium magnets. Overheating can permanently weaken a magnet.
Shattering risk
Despite the nickel coating, the material is delicate and cannot withstand shocks. Do not hit, as the magnet may crumble into hazardous fragments.
Nickel allergy
Studies show that nickel (the usual finish) is a common allergen. If your skin reacts to metals, avoid direct skin contact and select versions in plastic housing.
Powerful field
Exercise caution. Neodymium magnets attract from a long distance and connect with massive power, often quicker than you can move away.
Bodily injuries
Big blocks can crush fingers in a fraction of a second. Never put your hand between two attracting surfaces.
Fire risk
Powder created during cutting of magnets is combustible. Avoid drilling into magnets unless you are an expert.
Impact on smartphones
A strong magnetic field negatively affects the functioning of compasses in smartphones and GPS navigation. Keep magnets close to a smartphone to avoid damaging the sensors.
Do not give to children
Always keep magnets out of reach of children. Risk of swallowing is high, and the consequences of magnets connecting inside the body are fatal.
Electronic devices
Powerful magnetic fields can erase data on credit cards, HDDs, and storage devices. Stay away of min. 10 cm.
Medical interference
People with a pacemaker should maintain an absolute distance from magnets. The magnetic field can interfere with the operation of the implant.
